background image

5

DYNA-PRO

®

 Self-Priming Pool/Spa Pump Installation and User’s Guide

Start-up for Winterized Equipment

1.  Remove any temporary weather protection placed 

around system for shutdown.

2.  Follow filter manufacturer’s instructions for reactivation 

of the filter.

3.  Inspect all electrical wiring for damage or deterioration 

over the shutdown period. Have a qualified serviceman 

repair wiring as needed.

4.  Inspect and tighten all watertight connections.
5.  Open all valves in suction and return piping.
6.  Remove any winterizing plugs in piping system.
7.  Drain all antifreeze from system.
8.  Close all drain valves and replace all drain plugs in 

piping system.

9.  Prime pump according to 

Priming the Pump 

on page 4.

Summary of Contents for STA-RITE DYNA-PRO

Page 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS DYNA PRO INSTALLATION AND USER S GUIDE SELF PRIMING POOL SPA PUMP...

Page 2: ...Pump Draining the Pump Winterizing Start up for Winterized Equipment Maintenance Cleaning the Strainer Basket Pump Disassembly Removing Old Seal Pump Reassembly Installing New Seal Troubleshooting Rep...

Page 3: ...GS AND ALL INSTRUCTIONS IN THE OWNER S MANUAL BEFORE USING THIS PUMP THESE WARNINGS AND THE OWNER S MANUAL MUST BE LEFT WITH THE POOL OWNER SUCTION ENTRAPMENT HAZARD STAY OFF THE MAIN DRAINANDAWAYFROM...

Page 4: ...seriously injured by this high level of vacuum or may become trapped and drown It is absolutely critical that the suction plumbing be installed in accordance with the latest national and local codes f...

Page 5: ...To prevent flooding when removing the pump for service all flooded suction systems must have a gate valve in both the suction and discharge pipes 6 For most installations Pentair recommends installin...

Page 6: ...running see Figure 2 However if two main drains run into a single suction line the single suction line may be equipped with a valve which will shut off both main drains from the pump see Figure 2 Mor...

Page 7: ...entair salt chlorine generator Bonding 1 Bond the motor to the structure in accordance with the National Electrical Code and all other applicable national or local codes Use a solid copper bonding con...

Page 8: ...port losing the prime and causing the pump to run dry resulting in a damaged seal Continued operation in this manner could cause a loss of pressure resulting in damage to the pump case impeller and se...

Page 9: ...filter 3 Inspect all electrical wiring for damage or deterioration over the shutdown period Have a qualified serviceman repair wiring as needed 4 Inspect and tighten all watertight connections 5 Open...

Page 10: ...ill not fit on the strainer pot 7 Clean and inspect the lid O Ring and reinstall on strainer groove 8 Clean the O Ring groove on the strainer pot and reinstall the lid locking ring Note To prevent sti...

Page 11: ...the four 4 motor to seal plate screws Torque the screws to 60 80 inch lbs 69 92 kg cm 6 Apply a small amount of liquid detergent to the inside diameter of the rotating seal member 7 Slide the rotating...

Page 12: ...impeller is not clogged Disassemble the pump according to Pump Disassembly on page 6 If a blockage in the impeller if found clear the blockage and reassemble the pump according to Pump Reassembly on p...

Page 13: ...p adapter OR U11 199P 2 NPT adapter Box A Model No HP Motor Key No 1 Single Speed 115 230 60 1 MPRA6D 204L 3 4 A100DLL MPRA6E 205L 1 A100ELL MPRA6F 206L 1 1 2 A100FLL MPEA6D 204L 3 4 AE100DLL MPEA6E 2...

Page 14: ...4 1 C8 58P C8 58P C8 58P C8 58P C8 58P 15A 2 U178 920P U178 920P U178 920P U178 920P U178 920P 15B 2 U30 919SS U30 919SS U30 919SS U30 919SS U30 919SS 16 1 C4 77P C4 77P C4 77P C4 77P C4 77P 17 1 C35...

Page 15: ...NOTES...

Page 16: ...and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Water Pool and Spa Inc Tho...

Reviews: