background image

INDIRECT OIL FIRED

SWIMMING POOL

HEATER

Printed in Canada

2006/05/24

X40020 Rev. E

Save these instructions for future reference

Caution : Do not tamper with 
the unit or its controls.
Call a qualified service 
technician.

Model:

HMP-03

D

N

S

-0

52

6 R

év

 A

Manufactured by:

UTC Canada Corporation

ICP Division 

3400, Industrial Boulevard
Sherbrooke, Quebec 
J1L 1V8

Summary of Contents for ICP HMP-03

Page 1: ...Rev E Save these instructions for future reference Caution Do not tamper with the unit or its controls Call a qualified service technician Model HMP 03 D N S 0 5 2 6 R é v A Manufactured by UTC Canada Corporation ICP Division 3400 Industrial Boulevard Sherbrooke Quebec J1L 1V8 ...

Page 2: ...is extra power comes from the uniquely designed heat exchanger coupled with a high efficiency oil burner The pool water will rapidly reach its desired temperature under any climatic conditions The HMP 03 need not be in operation if the pool is not used We suggest that the heater be used based on need only in order to avoid unnecessary expenses To fully enjoy the power of your appliance use it only...

Page 3: ...utdoor Diffuser Kit The HMP 03 swimming pool heater must be installed with the Outdoor Diffuser Kit model GDK manufactured by ICP Canada according to the following instructions also see Figure 2 p 10 1 Remove the top flue pipe cover part F and the top casing panel part G 2 Insert the 6 inch diameter exhaust pipe in the smoke box collar align the pre drilled holes of the exhaust pipe with the flue ...

Page 4: ... for voiding the warranty 1 7 2 Outdoor diffuser kit model GDK With the outdoor diffuser kit no draft regulator is needed and the maximum over fire draft should be 0 045 W C after 5 minutes of operation 1 8 BURNER INFORMATION The oil burner of the swimming pool heater is factory installed and wired The nozzle is also installed but the technician must do the final air adjustment The burner is facto...

Page 5: ...ter is not clogged check the vacuum reading and make sure it is less than 6 in hg for a one pipe system and 12 in hg for a two pipes system 4 Check the electrical supply circuits breakers 5 Check the burner electrode adjustments refer to the burner instruction manual 6 Check if the pool thermostat is calling for heat 7 Check if the low water cut off green light is on 8 Check for air in the oil pum...

Page 6: ...d for an extended period of time OR the appliance is not used altogether follow this procedure 1 Close the valve located at the bottom of the oil tank that feeds the burner 2 Raise the thermostat to call for heat and cause the oil burner to start 3 Let the burner fire until there is no longer a flame and combustion is cut by the safety usually 30 to45 seconds after the flame extinguishes 4 Depress...

Page 7: ...ater level Q Observation door F Red light low water level R Pool heater water outlet G Low water cut off S Operation and Hi limit control HI 180 160 o F LOW 170 150 o F H Pool thermostat sensor location T Pool heater water inlet I 1 2 NPT drain plug U Safety valve at the back of the appliance J Feed water regulator and check valve device V Expansion tank K Outlet water temperature sensor location ...

Page 8: ...e telephone Day Night Dealer name and address START UP TEST RESULTS Nozzle Pressure lb psi Burner adjustments Primary air Fine air Draw Assembly CO2 Smoke scale Bacharach Gross stack temperature 0 F Ambient temperature 0 F Chimney draft W C Overfire draft W C Test performed by ...

Page 9: ...FIGURE 2 GDK 24 Installation 10 DNS 0524 Rev A ...

Page 10: ...FIGURE 3 Typical Piping Arrangement 11 DNS 0525 Rev A ...

Page 11: ...12 FIGURE 4 Wiring Diagram DNS 0518 Rev B ...

Page 12: ...7 Right side panel B02135 01 28A Top front panel ass y HMP 03 D only B02148 01 ITEM DESCRIPTION NUMBER 28B Top front panel ass y HMP 03 T only B02148 02 29 Front door ass y B02151 30 Water leak pan B02117 31 Front underneath covert B02116 32 Observation door ass y B01842 33 AFG V1 burner ass y B01532 01 34 Hex nut 3 8 16NC zinc F07F011 35 Oil inlet tube B01467 36 Gasket fixed flange N04Z026 37 Dra...

Page 13: ...S 1 Hex washer head self drilling screw 1 4 14 x 1 F03G010 Stainless steel 2 Diffuser ass y B01504 3 Diffuser bracket ass y B01506 4 Hex washer head self drilling screw 8 18 x 1 2 F03G009 Quantity 4 stainless steel 5 Flue pipe casing B01486 6 Stainless steel flue pipe B02118 ...

Reviews: