14
EN
CHAPTER 6
STARTING UP
•
1. Start the device pressing
•
2. Introduce the nominal pump
current:
•
Press and hold for 3 seconds.
•
We view on the intermittent screen the
nominal current with the ON led.
•
Via the keys and
adjust the
nominal current indicated on the pump
plate. See Note 1.
•
Press
to validate.
•
3. Introduce operating pressure:
•
Press
+
for 5 seconds.
•
Use the keys
or
to modify the
values.
•
Press
for 2 seconds.
•
We view start pressure flashing and
the
•
START ON led.
•
Via the keys
and
adjust the
start pressure from 0.5 to 7 bar.
•
Press
to validate.
•
4. Introduce stop pressure:
•
Press
for 3 seconds.
•
We view on the screen the stop
pressure flashing and the STOP ON led.
•
Press
to validate and to move to
the next one.
•
Via the keys
and
adjust the
stopping pressure from 1 to 8 bar.
•
Press
to validate.
•
5. I device remains configured and
ready for use.
•
The sequence of parameters is as
follows:
Before starting up the device it is necessary to read the previous points, especially "Hydraulic System" and "Electrical
Installation".
DANGER
NOTE 1
BASIC PROGRAMMING MENU
it is very important to introduce exactly the nominal current on the pump specifications plate.
Basic operational start-up consists of:
•
Press
+
+
for 5 seconds.
•
Use the keys
or
to modify the
values.
•
Press
to validate and to move to
the next parameter.
•
The sequence of parameters is as
follows:
ADVANCED PROGRAMMING MENU
IT
TYPE
SYSTEM REACTION
DEFAULT
SETTING
1
BAR
P
It allows selection of the units in which
the pressure between bar and psi is displayed
bar
2
rc0
rc1
Rapid cycles alarm:
- rc0: deactivated.
- rc1: alarm activated, when it is detected, a delay is produced in start-up to protect the pump.
- rc2: alarm activated, the pump stops when it is detected.
rc0
3
r.01
r. 99
If the rapid alarm cycles are activated in the previous point (rc1), we can select the period of time between
3 consecutive start-ups, in seconds. We consider as rapid cycle between 1" and 99".
5 seconds
4
Sb0
Sb1
Allows activation or deactivation of the display standby mode (Sb1) (Sb0) to save energy.
Sb0
Summary of Contents for Sta-Rite DIGITAL PT8
Page 10: ...8 IT 5 DIAGRAMMA A INDIVIDUALE GRUPPO SOLO SW2...
Page 19: ...17 EN 5 DIAGRAM A INDIVIDUAL GROUP ONLY SW2...
Page 28: ...26 FR 5 DIAGRAMME A INDIVIDUEL GROUPE UNIQUEMENT SW2...
Page 37: ...35 DE 5 DIAGRAMM A EINZELN GRUPPE NUR SW2 P Startdruck 0 5 bar...
Page 46: ...44 PT 5 DIAGRAMA A INDIVIDUAL GRUPO SOMENTE SW2 P Pinicial 0 5 bar...
Page 55: ...53 PL 5 SCHEMAT A INDYWIDUALNY ZESP TYLKO SW2...
Page 64: ...62 ES 5 DIAGRAMA A INDIVIDUAL GRUPO SOLO SW2 P P inicio 0 5 bar...