3
Maximum Ambient Temperature ............................ 104°F (40°C)
Liquid Temperature Range ...................................... 5°F to 250°F
(–15°C to +121°C)
Maximum Permissible Operating Pressure ...................... 435 psi
NOTE: The pump’s inlet pressure plus the discharge
pressure when the pump is running against a closed valve
must always be lower than the Maximum Permissible
Operating Pressure.
Electrical Data ............................................See Motor Nameplate
Dimensions and
Port-to-Port Lengths ..............................See Figure 2 and Table I
INSTALLATION:
LOCATION. Locate pump in a dry, well ventilated area, not
subject to freezing or extreme variations in temperature.
Mount pump a minimum of 6" from any obstruction or hot
surface. Install the pump with the motor shaft vertical. Make sure
that an adequate supply of cool air reaches the motor cooling fan.
Maximum ambient air temperature is 104°F (40°C).
For open systems requiring suction lift, locate the pump as close
to the water source as possible.
FOUNDATION. Foundation should be concrete or a similarly
rigid foundation to provide a secure, stable mounting base for
the pump.
Secure pump to foundation using all bolt holes. Refer to Figure
2 for bolt plate dimensions. Be sure that all four pads on the base
are properly supported.
Shim pump base to make sure that pump is level.
PIPING.
If there is any danger of the pump running against a closed
discharge valve, install a pressure relief or bypass valve in the
TABLE I – Single Phase – Maximum Height and Width Dimensions*
Model
Number
Dimension in Inches
A
B
C
D
E
F
PVM32-1-1D
22.3
13.9
7.9
2.6
38.8
10.0
PVM32-1D
22.3
13.9
7.9
2.6
38.8
10.0
PVM32-2-2D
27.0
13.9
7.9
2.6
43.5
10.0
PVM32-2-1D
27.0
13.9
7.9
2.6
43.5
10.0
PVM32-2D
27.0
13.9
7.9
2.6
43.5
10.0
PVM32-3-2D
29.8
13.9
7.9
3.1
46.8
10.0
TABLE II – Three Phase – Maximum Height and Width Dimensions*
Model
Number
Dimension in Inches
A
B
C
D
E
F
PVM32-1-1D
22.3
12.6
6.9
2.6
37.5
8.6
PVM32-1D
22.3
12.6
6.9
2.6
37.5
8.6
PVM32-2-2D
27.0
13.9
8.1
2.6
43.5
10.3
PVM32-2-1D
27.0
13.9
8.1
2.6
43.5
10.3
PVM32-2D
27.0
13.9
8.1
2.6
43.5
10.3
PVM32-3-2D
29.8
14.2
8.1
3.1
47.1
10.3
PVM32-3D
29.8
20.0
9.5
4.0
53.8
12.9
PVM32-4-2D
32.5
20.0
9.5
4.0
56.5
12.9
PVM32-4D
32.5
20.0
9.5
4.0
56.5
12.9
PVM32-5-2D
35.3
16.9
9.2
3.8
56.0
11.5
PVM32-5D
35.3
16.9
9.2
3.8
56.0
11.5
PVM32-6-2D
38.0
20.0
9.5
3.0
61.0
13.3
PVM32-6D
38.0
20.0
9.5
3.0
61.0
13.3
PVM32-7-2D
40.8
20.0
9.5
3.0
63.8
13.3
PVM32-7D
40.8
23.9
13.1
3.0
67.7
15.6
PVM32-8-2D
43.6
23.9
13.1
3.0
70.5
15.6
PVM32-8D
43.6
23.9
13.1
3.0
70.5
15.6
PVM32-9-2D
46.3
23.2
13.1
3.0
72.5
15.6
PVM32-9D
46.3
23.2
13.1
3.0
72.5
15.6
PVM32-10-2D
49.1
23.2
13.1
3.0
75.3
15.6
PVM32-10D
49.1
23.2
13.1
3.0
75.3
15.6
PVM32-11-2D
51.8
23.2
13.1
3.0
78.0
15.6
* Measurements represent the largest number possible for each model.
E
B
D
A
C
4-1/8
12-5/8
9-7/16"
11-1/16"
F
Figure 2. Height, width and baseplate dimensions for PVM32 Series
pumps.
PVM32 DIMENSIONS:
Warning:
Hazardous Voltage
Voltage can shock, burn, or cause death. Ground pump motor
correctly before connecting to power supply, per article 250-
80 of the National Electrical Code (NEC) in the U.S., or the
Canadian Electrical Code (CEC), as applicable.
Warning:
Explosion and Burn Hazard
Do not run pump with discharge valve closed; the water in
the pump may boil, with risk of explosion and steam burns to
anyone near.