Software Setup
9
Parameter Name
Default Value
0-01 Language
English
3-41 Ramp 1 Ramp Up Time
5.0 Sec
3-42 Ramp 1 Ramp Down Time
5.0 Sec
3-84 Initial Ramp Time
1.0 sec for Submersible / Off for Above Ground
4-12 Motor Speed Low Limit
30 Hz for Submersible / 0 Hz for Above Ground
4-14 Motor Speed High Limit
60 Hz
6-25 Terminal 54 High Ref. / Feedb. Value
100 PSI
14-20 Reset Mode
Automatic Reset x 3
14-21 Automatic Restart Time
10 Min
20-21 Setpoint 1
60 PSI
20-93 PID Proportional Gain
2.00
20-94 PID Integral Time
8.00 Sec
22-24 No Flow Delay
10 Sec
22-27 Dry Pump Delay
10 Min
22-40 Minimum Run Time
1 Min
22-41 Minimum Sleep Time
30 Sec
22-44 Wake-Up Ref./FB Difference
10%
29-00 Pipe Fill Enable
Enabled
29-02 Pipe Fill Speed
45 Hz
29-03 Pipe Fill Time
60 Sec
29-05 Filled Setpoint
10 PSI
24
Auto
On
25
Use My Personal Menu to access commonly
adjusted parameters: Setpoint, Ramp Times,
Transducer Limits and PID and Pipe Fill
Settings. See table below for a list of the
parameters and their default settings.
Quick
Menu
OK
To My Personal Menu
Refer to Danfoss Operating Instructions
(130R0336), Design Guide (130R0337), and
Programming Guide (130R0335) for further
details.