11 TECHNICAL SPECIFICATION
Supply voltage
230VAC, +10%, –15%, 50/60 Hz
Power consumption, average
4 VA
Main power switch
2-pole
Relay output
230V, max. 13A
Ambient temperature – operation
0 +40°C
Ambient temperature – transport
–20 +50°C
Protection class
IP 21
Terminals
Max. 2,5 mm²
Floor sensor with 3 m cable
NTC, 10KΩ / 25°C
Maximum length of floor sensor
cable
100 m, 2 x 1,5 mm² (230VAC cable
type)
Dimension with frame (Figure1)
H 82 x W 82 x D 57 mm
Colour
Polar white RAL 9010
Display
LCD with blue backlight
Control modes
Floor sensor (+5 +35°C)
Room sensor (+5 +40°C)
Room sensor with floor sensor
as a limiter
Room temperature control
accuracy EN15500
CA = 0,7K eu.bac certified
Floor sensing hysteresis
0,5°C (Factory settings adjustable
between 0,2-2,0°C)
Accuracy – floor/room sensor
± 0,5°C at 25°C
Program Selection
4 programs:
- Comfort (Fixed Program)
- EcoHome (Fully Customizable)
- EcoOffice (Fully Customizable)
- OFF
Back-up for set values
In non-volatile memory
Back-up for time and date
24 hours
Optional external set back feature 6 external set-back signals
Table 8
All manuals and user guides at all-guides.com