Protect electrical cord from sharp objects, hot surfaces, oil, and 

chemicals. Avoid kinking cord. Replace or repair damaged or 

worn cords immediately.
Do not handle pump or pump motor with wet hands or when 

standing on wet or damp surface, or in water.
Do not use this pump in a fish pond.

 

risk of electrical shock. Can burn or kill.

 

If your basement has water or moisture on floor, do not walk 

on wet area until all power has been turned OFF. If shut-off 

box is in basement, call electric company or hydro authority 

to shut-off service to house, or call your local fire department 

for instructions. Remove pump and repair or re place. Failure to 

follow this warning can result in fatal electrical shock. Oil on the 

pump or in the sump may indicate motor leakage and electrical 

shock hazard. Turn OFF power and check pump for oil leakage 

from impeller area. Replace pump if it leaks.

note: 

This unit is not designed for applications involving salt 

water or brine! Use with salt water or brine will void warranty.
Pump water only with this pump.

California proposition 65 Warning

 This product and related accessories contain 

chemicals known to the State of California to cause cancer, birth 

defects or other reproductive harm.

InStallatIon

1.  Install pumps in sump pit with minimum diameter of 12". 

Sump depth should be 18". Construct sump pit of tile, 

concrete, steel, or plastic. Check local codes for approved 

materials.

2.  Install pump in pit so that switch operating mechanism has 

maximum possible clearance.

3.  Pump should not be installed on clay, earth, or sand 

surfaces. Clean sump pit of small stones and gravel which 

could clog pump. Keep pump inlet screen clear.

 

note:

 

Do not use ordinary pipe joint compound on plastic 

pipe. Pipe joint compound can attack plastics.

4.  Install discharge plumbing. Use rigid plastic pipe and wrap 

threads with PTFE pipe thread sealant tape. Screw pipe into 

pump hand tight +1 to 1-1⁄2 turns.

 

risk of flooding.

 If a flexible discharge hose is 

used, make sure pump is secured in sump to prevent movement. 

Failure to secure pump may allow pump movement, switch 

interference, and prevent pump from starting or stopping.
5.  To reduce motor noise and vibrations, a short length of 

rubber hose (1-7⁄8" I.D., e.g. radiator hose) can be connected 

into discharge line near pump using suitable clamps.

6.  Install an in-line check valve to prevent flow backwards 

through pump when pump shuts off.

7.  Power Supply: Pump is designed for 115 V., 60 Hz., 

operation and requires a minimum 15 amp dedicated circuit. 

Both pump and switch are supplied with 3-wire cord sets 

with grounding-type plugs. For automatic operation, switch 

plug is inserted directly into outlet and pump plug inserts 

into opposite end of switch plug. For manual operation, 

pump plug is inserted directly into outlet.

 

pump should always be electrically grounded 

to a suitable electrical ground such as a grounded water 

pipe or a properly grounded metallic raceway or ground 

wire system.

 Do not cut off round ground pin.

  8. If pump discharge line is exposed to outside sub-freezing 

atmosphere, portion of line exposed must be installed so any 

water remaining in pipe will drain to the outfall by gravity. 

Failure to do this can cause water trapped in discharge to 

freeze which could result in damage to pump.

  9. After piping and check valve have been installed, unit is 

ready for operation.

10. Check operation by filling sump with water and observing 

pump operation through one complete cycle.

 

failure to make this operational check 

may lead to improper operation, premature failure, and 

flooding.

operatIon

 

risk of electric shock.

 Do not handle a pump 

or pump motor with wet hands, or when standing on wet or 

damp surface or in water.
1.  Shaft seal depends on water for lubrication. Do not operate 

pump unless it is submerged in water as seal may be 

damaged if allowed to run dry.

2.  Motor is equipped with automatic reset thermal protector. If 

temperature in motor should rise unduly, switch will cut off 

all power before damage can be done to motor. When motor 

has cooled sufficiently, switch will reset automatically and 

restart motor. If protector trips repeatedly, pump should be 

removed and checked as to cause of difficulty. Low voltage, 

long extension cords, clogged impeller, very low head or lift, 

etc., could cause cycling.

3.  Pump will not remove all water. If manually operated pump 

is operating and suddenly no water comes out of discharge 

hose, shut OFF unit immediately. Water level is probably 

very low and unit has broken prime.

note: 

For continuous operation, water depth must be at least 

2" (5 cm).

 

risk of electric shock.

 Before attempting to 

check why unit has stopped operating, disconnect power from 

unit. Do not handle pump with wet hands or  when standing on 

wet or damp surfaces, or in water.

note: 

No repair parts are available for these pumps.

Summary of Contents for Myers DS33P1

Page 1: ...2013 Pentair Ltd All Rights Reserved 253P7100 Rev 02 22 13 293 WRIGHT STREET DELAVAN WI 53115 WWW FEMYERS COM PH 888 987 8677 DS33P1 DS50P1 DS75P1 Installation Operation Parts For further operating installation or maintenance assistance Call 1 888 987 8677 ...

Page 2: ...ds Disconnect power before servicing Release all pressure within system before servicing any component Drain all water from system before servicing Secure discharge line before starting pump An unsecured discharge line will whip possibly causing personal injury and or property damage Check hoses for weak or worn condition before each use making certain that all connections are secure Periodically ...

Page 3: ...able clamps 6 Install an in line check valve to prevent flow backwards through pump when pump shuts off 7 Power Supply Pump is designed for 115 V 60 Hz operation and requires a minimum 15 amp dedicated circuit Both pump and switch are supplied with 3 wire cord sets with grounding type plugs For automatic operation switch plug is inserted directly into outlet and pump plug inserts into opposite end...

Page 4: ...ANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an impl...

Page 5: ...r Ltd All Rights Reserved 253P7100 Rév 22 02 13 293 WRIGHT STREET DELAVAN WI 53115 WWW FEMYERS COM PH 888 987 8677 DS33P1 DS50P1 DS75P1 Installation Fonctionnement Pièces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 888 987 8677 ...

Page 6: ...e la pompe ces limites et les dangers potentiels que présente son utilisation Avant d intervenir sur la pompe couper le courant Dissiper toute la pression du circuit d eau avant d intervenir sur un des éléments de la pompe Vidanger l eau du circuit avant d intervenir sur la pompe Bien immobiliser la canalisation de refoulement avant de faire fonctionner la pompe Une canalisation de refoulement non...

Page 7: ...ulement à l aide de colliers près de la pompe 6 Poser un clapet anti retour en ligne pour que l eau ne retourne pas dans la pompe lorsqu elle est arrêtée 7 Courant électrique Cette pompe est conçue pour fonctionner sur le courant électrique de 115 volts 60 Hz et et sur un circuit séparé d une puissance minimum de 15 ampères La pompe et l interrupteur sont livrés avec des cordons électriques à 3 co...

Page 8: ...TÉE SUSMENTIONNÉE NE DOIT PAS ÊTRE PROLONGÉE AU DELÀ DE LA DURÉE PRÉVUE AUX PRÉSENTES Certains états territoires et certaines provinces ne permettent pas l exclusion ou la limitation des dommages indirects ou fortuits ni les limitations relatives à la durée des garanties tacites Par conséquent il se peut que les limitations ou les exclusions stipulées dans les présentes ne s appliquent pas dans ce...

Page 9: ...Pentair Ltd All Rights Reserved 253P7100 Rev 02 22 13 293 WRIGHT STREET DELAVAN WI 53115 WWW FEMYERS COM PH 888 987 8677 DS33P1 DS50P1 DS75P1 Instalación Operación Piezas Para mayor información sobre el funcionamiento instalación o mantenimiento de la bomba Llame al 1 419 289 1144 ...

Page 10: ...taciones y posibles riesgos de la bomba Desconecte la energía eléctrica antes de efectuar reparaciones Alivie toda la presión dentro del sistema antes de reparar cualquier componente Drene toda el agua del sistema antes de efectuar reparaciones Asegure bien la tubería de descarga antes de poner en marcha la bomba Una tubería de descarga que no esté bien segura puede moverse y causar lesiones perso...

Page 11: ... 6 Instale una válvula de retención en línea para evitar retroflujo a través de la bomba cuando la bomba se apague 7 Suministro de corriente La bomba ha sido diseñada para una operación de 115 v 60 Hz y requiere un circuito dedicado con un mínimo de 15 amperios Tanto la bomba como el interruptor vienen con juegos de cordones trifilares con enchufes para conexión a tierra Para un funcionamiento aut...

Page 12: ...E IMPLÍCITA INCLUYENDO PERO SIN LIMITARSE A LAS GARANTÍAS IMPLÍCITAS DE COMERCIABILIDAD E IDONEIDAD PARA UN FIN ESPECÍFICO LAS GARANTÍAS LIMITADAS QUE ANTECEDEN NO SE EXTENDERÁN MÁS ALLÁ DEL PERÍODO DE DURACIÓN INDICADO EN LA PRESENTE Algunos estados no permiten la exclusión o limitación de daños incidentales o consecuentes o de limitaciones de tiempo sobre garantías implícitas de modo que es posi...

Reviews: