TROUBLESHOOTING
Timer
If an error is detected, an error screen will alternate with the
main display screen every few seconds, and the LED light will
be red.
During an error condition, the unit continues to monitor
the flow meter and update the remaining capacity. Once an
error condition is corrected, the unit returns to the operating
status it was in prior to the error, and regeneration resumes
according to normal programming. If an error is cleared by
reprogramming the unit in the Master Programming Mode,
the volume remaining may be reset to the full unit capacity
(as though it had just regenerated). If an error is present,
a regeneration can only occur manually by pressing and
holding the Extra Cycle button for 5 seconds. If the unit was
in regeneration when the error occurred, it will complete the
regeneration cycle and go into service.
When the problem is corrected, and the error no longer displays
(it may take several seconds for the unit to stop displaying the
error message), the unit will return to normal operation. The
LED light will no longer be red, and will turn Green if the unit is
regenerating, or Blue if the unit is in service.
Problem
Correction
A. Flashing/blinking display A. Power outage has occurred. Either
wait 5 minutes for blinking to stop, or
press any key on the keypad.
B. Unit not responding after
going into regeneration
B. Verify the unit is configured
correctly (ex: wiring valve type).
Perform a Master Reset by holding
the Shift button and cycling power.
Check and verify the choices selected
in Master Programming Mode.
C. Unit displays “ERROR
CODE: REPLACE UNIT”
(corrupted UAP)
C. Contact your local water treatment
professional.
Error Codes
Error
Code
Display
Message
Correction
01
ERROR CODE:
PROGRAM UNIT
Go through all screens in Master
Programming Mode.
02
ERROR CODE:
PROGRAM UNIT
Go through all screens in Master
Programming Mode.
03
ERROR CODE:
SERVICE UNIT
Perform a Master Reset by holding
the Shift button and cycling power.
Go through all screens in Master
Programming Mode. Manually initiate a
regeneration cycle by pressing the Extra
Cycle button for 5 seconds.
04
ERROR CODE:
SERVICE UNIT
Perform a Master Reset by holding
the Shift button and cycling power.
Go through all screens in Master
Programming Mode. Manually initiate a
regeneration cycle by pressing the Extra
Cycle button for 5 seconds.
05
ERROR CODE:
SERVICE UNIT
Call your local water treatment
professional as soon as possible. Leave
the unit running (do not unplug).
NOTE:
If the above corrections do not work, please contact
your local water treatment professional.
Error Display Screen Examples
Summary of Contents for FLECKXT
Page 1: ...www pentairaqua com FLECK XT SERVICE MANUAL...
Page 7: ...FLECK XT Service Manual 7 MASTER PROGRAMMING MODE FLOW CHART CONTINUED...
Page 17: ...FLECK XT Service Manual 17 61501 3200XT_3150XT_REVA 3150 POWER HEAD ASSY...
Page 19: ...FLECK XT Service Manual 19 61501 3200XT_3900XT_REVA 3900 POWER HEAD ASSY...
Page 21: ...FLECK XT Service Manual 21 9000 9100 9500 POWER HEAD ASSY 61501 3200XT 9_REVA...
Page 23: ...FLECK XT Service Manual 23 WIRING DIAGRAMS Single Piston...
Page 24: ...24 FLECK XT Service Manual WIRING DIAGRAMS CONTINUED Dual Piston...
Page 26: ...26 FLECK XT Service Manual...
Page 27: ...FLECK XT Service Manual 27...