MASTER PROGRAMMING MODE 

CONTINUED

14. Brine Line Flow Control Size

This program step allows the selection of the desired brine 

line flow control size in the unit (must match physical brine 

line flow control).

•  Press the Up or Down buttons to adjust this value.
•  Press the Extra Cycle button.

15. Auxiliary Relay Output

The next two displays are part of a series of settings used to 

program the optional relay output. The first setting turns the 

output on/off during regeneration only. The second turns the 

output on during service only, every time a set volume of water 

used has accumulated.

NOTE:   

When auxiliary outputs are in the OFF (default) 

setting, press the Up or Down buttons to set the first 

setting. Then press the Extra Cycle button to advance 

to the second setting.

a. Timed Auxiliary Relay Output Window  

(Start & End Time Setting)

This option setting consists of two displays. The first display 

sets the turn-on time of the output, referenced to the start 

of the first regeneration cycle. The second display sets the 

output turn-off time, referenced again to the start of the first 

regeneration cycle. An OFF setting cancels this setting. All 

settings are in minutes and output timing is synchronized with 

regeneration cycle timing.

Start Time:

 Any time during regeneration.

End Time:

 At start time, and anytime during the  

regeneration cycle.

b. Chemical Pump Auxiliary Relay Output Window

This option setting consists of two displays. The first display 

sets the volume of water flow at which the output turns on. 

The second display sets the on time (in seconds) of the output.

•  Activate output after volume set is reached.
•  Press the Shift button to select the digit you want to modify.
•  Press the Up or Down buttons to adjust this value.
•  Press the Extra Cycle button.

16. Flow Meter Size

This program step sets the size of the flow meter.

•  Press the Up or Down buttons to adjust this value.
•  Press the Extra Cycle button.

17. Maximum Flow Rate

This program step sets maximum flow rate of the generic  

flow meter.

•  Press the Shift button to select the digit you want to modify.
•  Press the Up or Down buttons to adjust this value.
•  Press the Extra Cycle button.

18. Pulses per Gallon/Liter

This program step sets the pulses per gallon/liter for generic 

flow meters.

•  Press the Shift button to select the digit you want to modify.
•  Press the Up or Down buttons to adjust this value.
•  Press the Extra Cycle button.

19. End of Master Programming Mode

Summary of Contents for FLECKXT

Page 1: ...www pentairaqua com FLECK XT SERVICE MANUAL...

Page 2: ...only This product must be installed in compliance with all state and municipal plumbing and electrical codes Permits may be required at the time of installation If daytime operating pressure exceeds...

Page 3: ...rees PPM 8 Water Hardness __________Grains French Degrees German Degrees PPM 9 Capacity Safety Factor A Zero B __________ 10 Volume Override __________ Gallons or M3 11 Regeneration Day Override A Off...

Page 4: ...ed and B the time of day matches the regeneration day override time Meter Immediate Regenerates as soon as the volume remaining has been depleted Meter Delayed Fixed Reserve A Volume remaining has bee...

Page 5: ...display when the unit is in regeneration Once all regeneration steps are complete the timer returns to in service displays a blue LED light and resumes normal operation Timer Operation During Program...

Page 6: ...al professional water dealer To Set Time of Day 1 Press and hold the Up or Down buttons for 2 seconds 2 Press the Shift button to select the digit you want to modify Entering Master Programming Mode 1...

Page 7: ...FLECK XT Service Manual 7 MASTER PROGRAMMING MODE FLOW CHART CONTINUED...

Page 8: ...Programming Mode 1 System Type This program step selects the system type Press the Up or Down buttons to adjust this value Press the Extra Cycle button 2 Valve Type This program step selects the valv...

Page 9: ...below for regenerant flow default cycle steps and times Regenerant Flow Cycle 1 Time Cycle 2 Time Down Flow Back Wash 10 Minutes Brine Slow Rinse 1 Hour Back Wash Filter Back Wash 15 Minutes Draw 0 UF...

Page 10: ...cycle An OFF setting cancels this setting All settings are in minutes and output timing is synchronized with regeneration cycle timing Start Time Any time during regeneration End Time At start time an...

Page 11: ...n and set the days press the Down button Press the Shift Up and Down buttons to move the cursor and change the value of the numbers Press the Extra Cycle button to proceed to the next step 4 Regenerat...

Page 12: ...8 m3 m 1 5 Inch Turbine 90 gpm 0 34 m3 m 2 Inch Paddle 350 gpm 1 32 m3 m 3 Inch Paddle 500 gpm 1 89 m3 m Press the Extra Cycle button 2 Peak Flow Rate This program step displays the peak flow rate 1 m...

Page 13: ...FLECK XT Service Manual 13 2510 2750 2850 2850S POWER HEAD ASSY 61501 3200XT 2_2750XT_2850XT_REVA 32 33 34...

Page 14: ...Switch Micro 20 2 11805 Screw Rd Hd 4 40 x 5 8 Type 1 21 1 13547 Strain Relief Flat Cord 22 1 19791 02 Meter Cable Assy Softflow 1 19791 04 Meter Cable Assy Turbine 100 inch 1 19791 05 Meter Cable Ass...

Page 15: ...Manual 15 2900S POWER HEAD ASSY 61501 3200XT_2900XT_REVA 10 19 20 21 28 39 34 11 12 14 17 18 15 16 15 17 13 6 22 23 45 44 2 5 6 7 4 11 3 8 9 1 17 26 13 24 25 27 17 33 43 33 40 42 32 38 29 33 30 20 7...

Page 16: ...t Cord 23 1 19121 Meter Cable Assy 3200NT 19121 08 Meter Cable Assy NT 35 inch w Connector 19121 09 Meter Cable Assy NT 99 5 inch 19121 10 Meter Cable Assy NT 303 5 inch 24 1 14202 01 Screw Hex Wsh Ma...

Page 17: ...FLECK XT Service Manual 17 61501 3200XT_3150XT_REVA 3150 POWER HEAD ASSY...

Page 18: ...y XT Right Hand 25 4 11235 Nut Hex 1 4 20 Mach Screw 26 1 16050 Ring Retaining 27 1 16059 Washer SS 88 3150 3900 28 1 16051 Ring Retaining Bowed 29 8 19800 Plug 140 Dia White 30 1 15806 Plug Hole Heyc...

Page 19: ...FLECK XT Service Manual 19 61501 3200XT_3900XT_REVA 3900 POWER HEAD ASSY...

Page 20: ...g Retaining Bowed 30 8 19800 Plug 140 Dia White 31 1 15806 Plug Hole Heyco 2693 32 1 19591 Plug 875 Hole Recessed Black 33 3 11080 Screw Flt Hd Mach 8 32 x 3 8 34 2 17967 Fitting Assy Liquid Tight Blk...

Page 21: ...FLECK XT Service Manual 21 9000 9100 9500 POWER HEAD ASSY 61501 3200XT 9_REVA...

Page 22: ...Screw Slot Flat Hd 4 40 x 2 12 inch 18 2 10339 Nut Hex 4 40 Zinc Plated 19 1 15810 Ring Retaining 20 2 19160 Screw Phil Pan Thread 6 32 x 3 8 21 1 14430 Screw Hex Wsh St 6 x 1 4 22 1 14044 Tie Cable...

Page 23: ...FLECK XT Service Manual 23 WIRING DIAGRAMS Single Piston...

Page 24: ...24 FLECK XT Service Manual WIRING DIAGRAMS CONTINUED Dual Piston...

Page 25: ...nking display A Power outage has occurred Either wait 5 minutes for blinking to stop or press any key on the keypad B Unit not responding after going into regeneration B Verify the unit is configured...

Page 26: ...26 FLECK XT Service Manual...

Page 27: ...FLECK XT Service Manual 27...

Page 28: ...emarks and logos are the property of their respective owners Because we are continuously improving our products and services Pentair reserves the right to change specifications without prior notice Pe...

Reviews: