background image

CONTROL OPERATION DURING A POWER FAILURE 

The NXT includes integral power backup. In the event of power failure, the control shifts into a power-saving 

mode. The control stops monitoring water usage, and the display and motor shut down, but it continues to 

keep track of the time and day for a minimum of 8 hours.The system configuration settings are stored in a non-

volatile memory and are stored indefinitely with or without line power. 
If power fails while the unit is in regeneration, the control will save the current valve position before it shuts 

down. When power is restored, the control will resume the regeneration cycle from the point where power 

failed. Note that if power fails during a regeneration cycle, the valve will remain in it’s current position until 

power is restored. The valve system should include all required safety components to prevent overflows 

resulting from a power failure during regeneration. 

NOTE:  After power is restored following a power failure, time of day will flash to indicate a power 

interruption. Press the Extra Cycle button to resume normal operation.

The control will not start a new regeneration cycle without line power. If the valve misses a scheduled 

regeneration due to a power failure, it will queue a regeneration. Once power is restored, the control will 

initiate a regeneration cycle the next time that the Time of Day equals the programmed regeneration time. 

Typically, this means that the valve will regenerate one day after it was originally scheduled. If the treated 

water output is important and power interruptions are expected, the system should be setup with a sufficient 

reserve capacity to compensate for regeneration delays.

CARE AND USE OF YOUR BRINE TANK (IF EQUIPPED)

Each time the softener regenerates, salty water (brine) is needed to recondition the media in the water tank. 

The brine is pulled from the salt tank at a controlled amount. If the salt tank does not contain enough salt, the 

brine is weak, the media will not fully recondition and untreated water will pass through. To ensure the highest 

level of performance of your water conditioning system, please observe the following:

•  Keep the brine tank filled with salt at all times. The salt level should always be higher than the water level 

in the brine tank.

•  Only use sodium chloride salt designed for water softeners. Other types of salt (rock or snow melting) 

may contain dirt and chemicals that will affect the quality of your water and the performance of your 

water softener. 

•  Keep the brine tank covered. 
•  Empty and clean the tank when enough debris accumulates interfering with operation of system.
•  Water filters do not have brine tanks

6 • 

Fleck

 NXT Owner’s Manual

Summary of Contents for FLECK NXT

Page 1: ...FLECK NXT OWNER S MANUAL waterpurification pentair com...

Page 2: ...ing system WARNING The power outlet must be grounded and always on If it is necessary to disconnect power unplug the AC adapter from its power source WARNING Only fill the brine tank with salt designe...

Page 3: ...digit selecting LED Status indicator Blue In service Flashing Blue Regeneration Queued Green Regeneration Flashing Green Standby Red Error with codes System Number Valve Address Valve State Flow Indi...

Page 4: ...g options refer to Master Programming Flow Chart Enter User Mode Press and hold the Up or Down buttons for 5 seconds Set Language Option Press Up or Down to select language Press the Extra Cycle butto...

Page 5: ...ic Bypass Valve To return the conditioner system to regular service turn both of the knobs on the bypass counter clockwise back to their original positions Manual Bypass This type of bypass system is...

Page 6: ...queue a regeneration Once power is restored the control will initiate a regeneration cycle the next time that the Time of Day equals the programmed regeneration time Typically this means that the val...

Page 7: ...ssage Displayed Correction Flashing time Power outage Press any button to clear flashing display See SETTING TIME OF DAY AND INITIATING A MANUAL REGENERATION to reset time if needed See CONTROL OPERAT...

Page 8: ...Because we are continuously improving our products and services Pentair reserves the right to change specifications without prior notice Pentair is an equal opportunity employer 44052 REV A JA16 2016...

Reviews: