TROUBLESHOOTING

Detected Errors

If a communication error is detected, an Error Screen will alternate with the main (time of day) screen every 

few seconds. 

•  All units In Service remain in the In Service position.
•  All units in Standby go to In Service.
•  Any unit in Regeneration when the error occurs completes Regeneration and goes to In Service.
•  No units are allowed to start a Regeneration Cycle while the error condition exists, unless they are 

manually forced into Regeneration.

•  When an error is corrected and the error no longer displays (it may take several seconds for all of the 

units in a system to stop displaying the error message), the system returns to normal operation.

NOTE: During the error condition the control continues to monitor the flow meter and update the volume 

remaining. Once the error condition is corrected all units return to the operating status they were 

in prior to the error. Regeneration queue is rebuilt according to the normal system operation. Or, if 

more than one unit has been queued for regeneration, then the queue is rebuilt according to which 

one communicates first.

Message Displayed

Correction

Flashing time

Power outage. Press any button to clear flashing display. 

See SETTING 

TIME OF DAY AND INITIATING A MANUAL REGENERATION to 

reset time if needed. See CONTROL OPERATION DURING A 

POWER FAILURE for more information.

Detected Error = Matching Address

Contact your local water treatment professional.

Detected Error = Program Mismatch

Detected Error = No Message #X

Detected Error = E2 Reset Unit

Test Mode

Black Squares on screen

INI on screen for more than 2 minutes

CHG on screen for more than 2 minutes

Common Issues

Problem

Solution

Control valve fails to regenerate

Check for power outage and verify unit is plugged in. Attempt to 

perform a manual regeneration. See SETTING TIME OF DAY AND 

INITIATING A MANUAL REGENERATION. If problem still exists, 

contact your local water treatment professional.

Water does not feel or appear soft

Check salt in brine tank and ensure salt level is above water 

level. If problem still exists, contact your local water treatment 

professional.

Unit uses too much salt

Contact your local water treatment professional.

Loss of water pressure
Iron in conditioned water
Excessive water in brine tank
Other problems with the water softener
Power Outage

See CONTROL OPERATION DURING A POWER FAILURE for more 

information.

Fleck

 NXT Owner’s Manual • 7

Summary of Contents for FLECK NXT

Page 1: ...FLECK NXT OWNER S MANUAL waterpurification pentair com...

Page 2: ...ing system WARNING The power outlet must be grounded and always on If it is necessary to disconnect power unplug the AC adapter from its power source WARNING Only fill the brine tank with salt designe...

Page 3: ...digit selecting LED Status indicator Blue In service Flashing Blue Regeneration Queued Green Regeneration Flashing Green Standby Red Error with codes System Number Valve Address Valve State Flow Indi...

Page 4: ...g options refer to Master Programming Flow Chart Enter User Mode Press and hold the Up or Down buttons for 5 seconds Set Language Option Press Up or Down to select language Press the Extra Cycle butto...

Page 5: ...ic Bypass Valve To return the conditioner system to regular service turn both of the knobs on the bypass counter clockwise back to their original positions Manual Bypass This type of bypass system is...

Page 6: ...queue a regeneration Once power is restored the control will initiate a regeneration cycle the next time that the Time of Day equals the programmed regeneration time Typically this means that the val...

Page 7: ...ssage Displayed Correction Flashing time Power outage Press any button to clear flashing display See SETTING TIME OF DAY AND INITIATING A MANUAL REGENERATION to reset time if needed See CONTROL OPERAT...

Page 8: ...Because we are continuously improving our products and services Pentair reserves the right to change specifications without prior notice Pentair is an equal opportunity employer 44052 REV A JA16 2016...

Reviews: