6.4
Salt volume per regeneration
6.4.1
Salt volume definition
Set the weight of salt to be used during regeneration using the following table and formula.
Salt weight
[g/L
resin
]
Exchange capacity
[°tH/m
3
/L
resin
]
Salt weight
[g/°tH/m
3
]
80
4
20
125
5
25
180
6
30
Weight of salt to be set = Volume of resin [L] x Salt weight [g/L
resin
]
Example
16 liters of resin x 125 g = 2000 g (2 kg of salt).