BYPASS OPERATION

1.  Valve is in service when blue handles are turned parallel to inlet and out.  
2. Valve is in bypass when both handles are turned clockwise and are perpendicular to inlet and outlet ports.

3. To depressurize a downflow system: 

  a. Turn blue handle of supply side clockwise to be perpendicular to port.  

  b. Open a downstream water tap /faucet to relieve pressure.  

  c. Turn blue handle on treated water side clockwise so it is perpendicular to the port.  

  d. Remove the Fleck 125 In-and-Out Valve by slowly unthreading the coupling nuts.
4. To depressurize an upflow system:
  a. Turn off main water supply.
  b. Open a downstream water tap to relieve pressure.

  c. Turn both blue handles clockwise so they are perpendicular to the ports.

  d. Turn main water supply back on.
  e. Remove the Fleck 125 In-and-Out Valve by slowly unthreading the coupling nuts.

As an option, a relief valve can be installed in either of the two ¼”-18 NPT ports and used to relieve pressure in the Fleck 125 In-and-Out  
Valve 

after the bypass valve has been put in the bypass position. Follow the instructions below, items 7 and 8, for preparing these   

ports for use.

DIMENSIONAL DRAWINGS 

 

29.6

1.17  

 

47.8

1.88  

 

69.7

2.74  

 

25.4

1.00  

 

36.8

1.45  

 

55.8

2.20  

 

68.6

2.70  

 

120.7

4.75  

 

133.2

5.24  

1/4"-18 NPT FEMALE THREAD

TWO PLACES

TO OPEN, DRILL THROUGH

WITH 5/16" DRILL MAX.

 

36.8

1.45  

 

47.9

1.89  

 

25.4

1.00  

 

69.7

2.74  

 

68.6

2.70  

 

138.4

5.45  

 

36.8

1.45  

 

55.8

2.20  

 

145.8

5.74  

1/4"-18 NPT FEMALE THREAD

TWO PLACES

TO OPEN, DRILL THROUGH

WITH 5/16" DRILL MAX.

62134-01

62134-02

B

A

B

1

3

4

4

3

2

1

2

TITLE

SIZE

SCALE

SHEET 1 OF 1

DWG NO.

REV

Pentair Residential

Filtration, LLC

CHECKED

APPROVED

APPROVALS

DATE

THIRD ANGLE

PROJECTION

DRAWN

LINE DRWG IN OUT HEAD ASSY

C

1:2

PS

5

5

C

D

D

C

REVISIONS

DATE

APP'D

DESCRIPTION

REV.

PCO

ZONE

B

A

DO NOT SCALE DRAWING. DIMS. ARE IN INCHES [mm]

INTERPRET DIMS AND TOLERANCES PER ASME Y14.5M -2009

UNLESS OTHERWISE SPECIFIED:

ALL FINISHED MACHINED SURFACES  125       OR BETTER.

TOLERANCES:

  ANGLES :     

 1

  1 PLACE  .X:  

 .015  [0.38]

  2 PLACE  .XX:  

 .01  [0.3]

  3 PLACE  .XXX: 

 .005  [0.13]

BR42888

09/02/2020

THIS DOCUMENT IS SOLELY THE PROPERTY OF PENTAIR

RESIDENTIAL FILTRATION, LLC.  REPRODUCTION, USE 

DISCLOSURE, OR TRANSMISSION OF THIS DOCUMENT OR

DETAILS CONTAINED HEREIN, IN PART OR IN WHOLE, IS 

PROHIBITED WITHOUT THE WRITTEN CONSENT OF PENTAIR 

RESIDENTIAL FILTRATION, LLC ENGINEERING. THIS 

DOCUMENT AND ANY COPIES SHALL BE RETURNED TO

PENTAIR RESIDENTIAL FILTRATION, LLC UPON REQUEST.

  COMPONENTS / ASSEMBLIES TO BE COMPLIANT AND COMPATIBLE WITH EUROPEAN UNION DIRECTIVE 2011/65/EEC (RoHS2) & REGULATION (EC)1907/2006 (REACH) REQUIREMENTS

62134LNE

1.  The information, specifications and illustrations in the manual are based on the latest information available at the time of release. 

 

The manufacturer reserves the right to make changes at any time without notice. 

2. This product should be installed by a plumbing professional. 
3. This unit is designed to be installed on potable water systems only.
4. Check all applicable plumbing and building codes for installation compliance It is established that when daytime water pressure exceeds 80 psi (5.5 bar), 

 

the maximum pressure rating of 125 psi (8.6 bar) can be exceeded. A pressure regulator must be installed on this system or warranty is voided.

5. Do not place the unit in direct sunlight. Black units will absorb radiant heat, increasing internal temperatures.
6. Do not strike the valve or any of the components.
7. Do not use petroleum-based lubricants such as Vaseline, oils, or hydrocarbon-based lubricants on any o-rings. Use only 100% silicone lubricants.
8. When using test ports:
  - To open ports, drill through with clean drill no larger than 5/16” prior to installation of Fleck 125 In-and-Out Valve on tank. Use a clean drill bit free of oil    

   and do not use any drilling lubricant.

  - Be sure to clean out any chips or debris prior to installation.
  - Do not use more than 2 wraps of Teflon tape when installing a component to these ports. Do not use pipe dope.
  - When installing component into the ¼-18 NPT ports, do not exceed 25 Lb-in torque.