7.
Fault-finding and
rectification
Fault-finding on the swimming pool pumps must
be carried out only by specially qualified
personnel.
Follow the instructions given below for
the rectification of faults:
>
21
<
Fault
■
Pump failure / no
performance or too low
performance
■
Pump fails to suck
■
Too little water at
pool inlet
■
Pump fails to start
■
Pump generating
loud noises
■
Pump turns in wrong
direction: 400 V ver-
sions only
■
Motor gets very hot
Cause
Blocked line / preliminary filter /
impeller or worn impeller
Suction height too high / distance to
pool too great / pipe cross-section
too small
Blocked line / preliminary filter / filter
not flushed / pump too weak
Dirt between impeller and reverse
guide wheel / defective condenser
(230 V version) / power supply failure
Dirt in the pump / defective motor
bearing / incorrect installation
Incorrect electrical installation,
phases switched / performance
reduced by 50% / pump gets very hot
Inadequate ventilation / irregular
water supply
Remedy
Consult your dealer
Fit suction line correctly / fill preliminary filter with
water / check line for leaks / check pump cover and
drain plugs
Check preliminary filter / flush filter / check line for
leaks
Consult your dealer
Clean pump / Consult your dealer
Consult an electrician
Increase air supply / check water level in pool
Summary of Contents for 5P2R
Page 41: ...1 3 1 4 2 2 1 2 2 EU 41...
Page 42: ...2 3 2 3 1 2 3 2 3 0 42...
Page 43: ...3 1 4 4 1 4 2 5 43...
Page 44: ...5 Anti Vortex 2 5 1 25 5 1 3 5 1 2 2 5 5 1 3 5 1 4 5 2 44...
Page 45: ...50 5 3 3 400V I n 30mA 400V 6 6 1 6 2 45...
Page 46: ...7 46 400B 230 50...
Page 47: ...8 8 1 8 2 8 3 1 2 3 4 47...
Page 48: ...8 4 48 P P P P R P R P S P R S w m h m m m h h m w h...
Page 49: ...9 9 1 9 2 49...
Page 54: ...Notizen Notice Notices...