3. INSTALLATION
3.1 Lifting
The machine can be lifted in one of the following conditions:
- Machine without any kind of packing
- Machine packed in a cardboard box
3.1.1 Machine without any type of packing
It is possible to lift only one machine at a time:
- machines with a weight below 25 Kg: the machine can be
lifted manually by one operator
- machines with a weight ranging from 25 and 50 Kg: the
machine can be lifted manually by two operators
- machines with a weight above 50 Kg: the machine can be
lifted by means of appropriate lifting and slinging equipment
3.1.2 Machine packed in a cardboard box
It is possible to lift several machines packed in a cardboard
box, depending on the machine weight. Packed machines are
maintained in position by means of the inert material that fills
the box.
- machines with a weight below 25 Kg: the machine can be
lifted manually by one operator
- machines with a weight ranging from 25 and 50 Kg: the
machine can be lifted manually by two operators
- machines with a weight above 50 Kg: the machine can be
lifted by means of appropriate lifting and slinging equipment
3.2 Transportation
The machine must be transported in the following conditions:
- Machine in fixed position without possibility of moving
- Machine protected from atmospheric agents
Danger
Warning
Ascertain that the conditions referred to in
the points above are met during
transportation
3.3 Storage
3.3.1 Characteristics of the storage area
The storage area should have the following physical
characteristics:
- Sufficient extension to contain the machine and the packing,
when present, and to enable its lifting by means of the lifting
devices provided
- Flat and horizontal resting surface
- Resting surface with a capacity above the weight of the
machines stored
- Protection against accidental impacts
3.3.2 Environmental characteristics of the storage
area
The storage area should have the following environmental
characteristics:
- Acceptable temperature range: +7 °C ÷ +50 °C
- Relative humidity range: 30 ÷ 90%
- Protection from atmospheric agents
Warning
Keep the machine in horizontal position
3.4 Preliminary inspections
3.4.1 Assessment of damage
- Check the integrity of the packing
- Open the packing and extract the machine
-
Check that the received machine complies with the
characteristics indicated in the order
- Check that the machine has not suffered damage, and verify
in particular that the following components are integral:
- Motor fan cover
- Terminal block cover
- Coupling joint protection
- Cast iron parts
Warning
Keep the original packing in the event it
were necessary to transport the machine in
future
3.4.2 Damage reporting
If non compliance characteristics or damages are detected,
immediately report the problem to PENTAIR WATER ITALY or
to the distributor within and no later than 8 (eight) days from
the date of purchase.
3.5 Preparation of the installation site
3.5.1 Characteristics of the installation site
The installation site should have the following characteristics:
- Simplify the positioning and access to the machine
- Enable a safe connection to the electric system
- Enable safe connections to tubing
- Offer an appropriate natural and/or lighting designed to
guarantee full operational safety
- Offer a minimum distance of 150 m from each point of the
machine and from obstacles
- Offer a free space of at least 300 mm above the machine to
guarantee a sufficient ventilation of the motor fan.
Warning
Do not cover or obstruct the motor fan
cover grid
Environmental conditions
- Acceptable temperature range: +7 °C ÷ +40 °C
- Acceptable relative humidity range: 30 ÷ 90%
- Protection from atmospheric agents
Summary of Contents for Nocchi R2T
Page 15: ...Prestazioni Performances Performances Leitungen Prestaciones Prestaties R2T R4T 40 76...
Page 16: ...Prestazioni Performances Performances Leitungen Prestaciones Prestaties R2T R4T 50 77...
Page 17: ...Prestazioni Performances Performances Leitungen Prestaciones Prestaties R2T R4T 65 78...
Page 18: ...Prestazioni Performances Performances Leitungen Prestaciones Prestaties R2T R4T 80 79...
Page 19: ...Prestazioni Performances Performances Leitungen Prestaciones Prestaties R2T R4T 100 80...
Page 20: ...Prestazioni Performances Performances Leitungen Prestaciones Prestaties R2TD R4TD 40 81...
Page 21: ...Prestazioni Performances Performances Leitungen Prestaciones Prestaties R2TD R4TD 50 82...
Page 22: ...Prestazioni Performances Performances Leitungen Prestaciones Prestaties R2TD R4TD 65 83...
Page 23: ...Prestazioni Performances Performances Leitungen Prestaciones Prestaties R2TD R4TD 80 84...
Page 24: ...Prestazioni Performances Performances Leitungen Prestaciones Prestaties R2TD R4TD 100 85...