8

18" MIN. FROM  WATER 
TO TOP OF FACE RING

12" MIN. FROM BOTTOM 
OF JUNCTION BOX 
OR LOW VOLTAGE 
TRANSFORMER TO WATER LINE

TO EXISTING 
BONDING 
CONNECTOR

WATER 
LEVEL

TOP OF FACE RING 
CORRESPONDS 
TO CENTER OF 
MOUNTING HUB

RIGID CONDUIT 

 

48" 

MIN.

TO GFCI, CIRCUIT 
BREAKER AND 
POWER SOURCE

PILOT SCREW AT TOP

MOUNTING HUB 

b.

The junction box, or the low voltage transformer for 12 volt models, is located at least
12 inches above water level and at least 48 inches from the edge of the pool, see
Figure 5.

c.

The light fixture and all metal items within five (5) feet of the pool must be properly
electrically bonded.

d.

The mounting bracket must be properly installed so that the top edge of the face ring
of the Nicheless Light is at least 18 inches below the surface of the water in the pool,
see Figure 5.

e.

The mounting bracket and mounting hub must be properly electrically bonded and
grounded via the No. 8 AWG ground connector located at the rear of the Nicheless
fixture, see Figure 5.

2.

Consult the local building department to be certain that the pool's electrical system meets
all applicable requirements.

3.

Install this light fixture only in a Pentair Products mounting bracket. Mounting brackets
made by other manufacturers may not provide proper bonding and grounding connections.

Figure 5

Section 2: Replacing light fixture in existing pools 

(Continued)

9

B. Replacing light fixture after electrical system requirements are met

1.

Turn off main electrical switch or circuit breaker, as well as the switch which operates the
Nicheless Light.

2.

To remove light assembly, remove captive screw at top of housing, remove light assembly
from mounting bracket, and place assembly on deck. Take care not to scratch the lens.

3.

Remove junction box cover, disconnect the light fixture wires, and pull the cord through the
conduit.

4.

Feed the new light fixture cord through the conduit from the Nicheless Fixture to the
junction box.

NOTE:

 Depending on the length of the conduit, special tools may be required to pull the

cord through the conduit.

5.

Wrap a length of the cord up to a maximum of eight (8) feet long on the back of the light
assembly. Wind a minimum of three (3) wraps of cord so that the last wrap stops at the top
of the light. This extra cord allows you to bring the light out of the pool for installation of a
new lamp and for servicing.

NOTE: 

 Leave  2" to 3" of slack cord at the top so that the light may be tipped back  for

removal.

6.

Feed the remaining cord through the conduit hole in the mounting hub. Place hook
mounting bracket over pin on the bottom of the mounting bracket and press down lightly to
secure into place. Secure at top of the light with the captive screw.

7.

Cut the cord at the junction box, leaving at least six (6) inches of cord to make
connections.

8.

Strip six (6) inches of the outer cord jacket from the cord to expose the three insulated
wires. Be careful not to damage the insulation on the three inner wires.

9.

Connect cord to electrical wires at Junction Box, be sure not to pull the three (3) inches of
slack cord at the back of the light through the conduit when connecting the wires. All wiring
should be connected to a Class A GFCI in accordance with electrical codes, see Section
2.A.1.a on page 7.

10.

Connect all three wires to the corresponding circuit wires in the junction box and secure the
junction box cover in place.

11.

Before operating the light for more than 10 seconds, fill pool until the Nicheless Light is
completely submerged in water. To check for proper operation, turn on main switch or
circuit breaker, as well as the switch which operates the Nicheless Light.

          WARNING:

 Failure to bring the pool's electrical system up to code requirements

before    installing this Nicheless Light will create an electrical hazard which could result
in death or serious injury to pool users, installers, or others due to electrical shock, and
may also cause damage to property.

Section 2: Replacing light fixture in existing pools 

(Continued)

Summary of Contents for Nicheless Light AquaLumin II

Page 1: ...t Assembly 1 P N78887800 AquaLumin II Vinyl Mounting Bracket Assembly 3 4 P N78887700 Section Contents 1 Installing a mounting bracket and light fixture during new vinyl pool construction 3 2 Replacin...

Page 2: ...Pentair Water Pool and Spa Inc Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products Pentair Water Pool and Spa I...

Page 3: ...N BOX OR LOW VOLTAGE TRANSFORMER TO WATER LINE TO EXISTING BONDING CONNECTOR WATER LEVEL TOP OF FACE RING CORRESPONDS TO CENTER OF MOUNTING HUB RIGID CONDUIT 48 MIN TO GFCI CIRCUIT BREAKER AND POWER S...

Page 4: ...wall where light is to be installed The top of the light face ring must be 18 inches below normal water level as required by NEC Article 680 2 Cut or punch a three 3 inch diameter hole through pool w...

Page 5: ...the remaining new sealing screw through the circular hole located at the BOTTOM 6 o clock of the back of the housing and loosely tighten it into the face ring The BOTTOM 6 o clock circular hole is ac...

Page 6: ...lamp to the left compressing the spring in the spring loaded lamp socket until the right side of the lamp comes free from the fixed socket end 9 Install the new lamp by performing step 8 a through c i...

Page 7: ...than 10 seconds unless it is totally submerged in water Without total submersion the light assembly will get extremely hot which may result in serious burns or in breakage of the lamp or lens This may...

Page 8: ...t fixture cord through the conduit from the Nicheless Fixture to the junction box NOTE Depending on the length of the conduit special tools may be required to pull the cord through the conduit 5 Wrap...