IntelliComm II Interface Adapter Installation and User’s Guide
4
Connecting to a Compool
®
Control System
Connection from IntelliComm II to a Compool control system utilizes the RJ12
adapter (provided in the kit), and the IntelliFlo RS-485 communication cable
(provided with the pump).
Compool Models Compatible with IntelliComm II (see page 6 and 7)
Compool CP-3xxx series, CP-2000 and Time Master, CP-1000, CP-2020, Swim
Master LX-20, LX-42, CP-2020, LX-100, LX-80 Commercial and CP-100 control
systems. Note: IntelliComm II does not support the LX-820 Commercial system.
Compool Models Compatible with IntelliComm II
(Using an External 9 VDC 200mA AC Power Adapter)
The following Compool models are compatible with IntelliComm II using an
external 9 VDC, 200mA AC power adapter: Compool CP-30, LX-220, LX-40.
Accessing the Compool Circuit Board
The Compool control system circuit board is located in the power center. Refer
to the Compool control system owner’s manual for access information.
Connecting power to the IntelliComm II from a Compool
CP3xxx circuit board
(see page 5 and 7)
1.
Connect RJ12 adapter power wires (9-24V DC/AC)
: From the RJ12
adapter, connect the BLACK wire and RED wire to the RS-485 GND
(BLACK) and PWR (RED) terminal respectively.
NOTE: For LX-100:
Connect the YELLOW wire from RJ12 to IntelliComm II Red (PWR)
screw terminal. Note: To avoid circuit board damage, DO NOT
connect the RED and YELLOW wires together to Red (PWR)
terminal, leave RED UNCONNECTED (see page 6).
2.
Connect RJ12 adapter cable plug to the Compool COM PORT
:
Disconnect the Compool control panel RJ12 plug from the Compool
circuit board COM Port and connect it to the RJ12 adapter (provided).
Connect the RJ12 adapter plug into the COM Port (use black plug for
LX-100) on the Compool circuit board (see page 5).
3.
Connecting AUX cables:
Choose the functions you wish to control on
the Compool system. Connect the auxiliary cables (provided in kit) from
the IntelliComm II input terminals (GPM/RPM 1, 2, 3, 4) to the auxiliary
connector on the Compool circuit board. Typically, GPM/RPM 1 input
terminal, connects to Compool FILTER PUMP output terminal. Choose
the other functions on the Compool board and connect them to
GPM/RPM 2, 3, and 4 input terminals.
4.
Connecting IntelliComm II to IntelliFlo:
For IntelliComm II to IntelliFlo
wiring information, see page 3.
6.
Mounting the IntelliComm II
(see page 20).
7.
Setting up IntelliFlo speeds and flow rates
(see page 16).
Always disconnect AC POWER to the LOAD CENTER at the circuit
breaker. Also, disconnect AC power to the PUMP
before installing the
IntelliComm II interface adapter. Failure to do so could result in death
or serious injury to the service person, pool users or others due to
electric shock. Read all
SAFETY PRECAUTIONS on page i
before
starting.