IntelliComm II Interface Adapter Installation and User’s Guide
2
Connecting to IntelliComm II Input Program Terminals
There are four (two-wire) cables provided in kit for interface connections from the
automation control system circuit board, to the four IntelliComm II program (GPM /
RPM) input terminal (see page 3). The input terminal cable wires are not polarized.
Plugs/wires can be connected in any order.
Connecting IntelliComm II to a Valve Actuator
A Valve Actuator can be connected from the automation control system circuit
board to any one of the IntelliComm II input terminals (1-4) by splicing into the
valve actuator cable using the provided two-wire input terminal cable
(see page 3).
Connecting Power (9-24 VDC) to IntelliComm II
Power to the IntelliComm II requires a 9-24VDC, 200mA power source, which
can be supplied from the automation control system circuit board or an
AC to DC power adapter. For VDC power connection on Compool, Jandy and
Hayward control systems, see pages 4 - 13.
Screw terminal:
Connects to the pump via a two pin 50 ft.
communication cable (P/N 350122) provided with the pump.
Also connects to a 9-24VDC, 200mA power source (automa-
tion control system circuit board)
Four (9 - 24V DC/AC) input
terminals (GPM / RPM 1, 2, 3, 4):
Each input terminal connects to an
output relay or valve terminal on
the automation control system
circuit board via a two-pin AUX
cable.
Power LED on when power is applied.
IntelliComm II Interface Adapter Connections
IntelliComm II
Interface Adapter
LED on when power (9-24V DC) is
received from automation system.
1
2
3
4
IntelliFlo pump AC connection
If multiple pump speeds are required, the IntelliFlo pump must be wired to a
circuit breaker
not
to a relay.
Note:
If the IntelliFlo pump is used in a commercial application or connected to
an Emergency Shut-Off switch, the pump must be connected to a relay for proper
Emergency Shut-Off operation.
Salt Chlorine System Connections
All Salt Chlorine Generator (SCG) units must be connected to the Filter Pump
relay output. If the Filter Pump relay output is being used for the IntelliComm II,
then a RYALX can be used if a SCG is present in the system. For more information
about using the RYALX see page 7.