IntelliComm II Interface Adapter Installation and User’s Guide
18
IntelliFlo Pump Warnings and Alarm Conditions
The IntelliFlo VS-3050 alarms and warnings are indicated by flashing LEDs on
the control panel. For example, if a “Drive Temperature” warning occurs, the LED
will blink two times, then Off, then blink two times. This sequence is repeated until
the condition is cleared.
•
Warning condition:
If a warning condition occurs the pump will
be continue to run but at a reduced speed. The Green LED
executes a sequence of blinks to indicate which alarm or
warning has occurred.
•
Alarm condition:
If an alarm condition occurs the pump will drive
stop running. The red LED flashes continuously to indicate the
presence of an alarm. The alarm LEDs will reset when the
condition clears.
Programming IntelliFlo VS+ SVRS Speeds
Press the menu button. Press the down arrow until “Ext Ctrl.” is displayed.
Follow the instructions as described on page 10 for the IntelliFlo VF (steps 1
through 12). However there is one difference. The IntelliFlo VS+SVRS does
not have any default “Schedules” so it is not necessary to deactivate any
schedules so it will only run commands from the IntelliComm II. But, just like
the IntelliFlo VF it can be programmed to run scheduled flows and when it
gets a command from IntelliComm II to run a program the IntelliComm II
program will take priority.
Note: If more than one terminal input is activated on the IntelliComm II the
highest number input will take priority, regardless of the pump setting. For
example: If program 1 and program 3 are activated on the IntelliComm II
The pump will run program 3, regardless of speed, flow or order of activa-
tion.
When a command to run is sent from the IntelliComm II to the VS+SVRS the
pump’s display will show “Running Prog. 1” and the countdown timer on the
IntelliFlo VF display will show 00:01.
CAUTION:
When performing maintenance on the system or the pump
switch the power to the pump off at the circuit breaker. This will ensure that
the pump does not switch on from remote operation or run a schedule.