IntelliFlo Pump Warnings and Alarm Conditions

The IntelliFlo VS-3050 alarms and warnings are indicated by flashing LEDs on
the control panel. For example, if a “Drive Temperature” warning occurs, the LED
will blink two times, then Off, then blink two times. This sequence is repeated until
the condition is cleared.

Warning condition:

 If a warning condition occurs the pump will

be continue to run but at a reduced speed. The Green LED
executes a sequence of blinks to indicate which alarm or
warning has occurred.

Alarm condition:

 If an alarm condition occurs the pump will drive

stop running. The red LED flashes continuously to indicate the
presence of an alarm. The alarm LEDs will reset when the
condition clears.

Programming IntelliFlo VS+ SVRS Speeds

Press the menu button. Press the down arrow until “Ext Ctrl.” is displayed.
Follow the instructions as described on page 10 for the IntelliFlo VF (steps 1
through 12).  However there is one difference.  The IntelliFlo VS+SVRS does
not have any default “Schedules” so it is not necessary to deactivate any
schedules so it will only run commands from the IntelliComm II.  But, just like
the IntelliFlo VF it can be programmed to run scheduled flows and when it
gets a command from IntelliComm II to run a program the IntelliComm II
program will take priority.

Note: If more than one terminal input is activated on the IntelliComm II the
highest number input will take priority, regardless of the pump setting.  For
example:  If program 1 and program 3 are activated on the IntelliComm II
The pump will run program 3, regardless of speed, flow or order of activa-
tion.

When a command to run is sent from the IntelliComm II to the VS+SVRS the
pump’s display will show “Running Prog. 1” and the countdown timer on the
IntelliFlo VF display will show 00:01.

CAUTION:

  When performing maintenance on the system or the pump

switch  the power to the pump off at the circuit breaker.  This will ensure that
the pump does not switch on from remote operation or run a schedule.

Summary of Contents for IntelliComm II

Page 1: ...stallation and User s Guide Installation and User s Guide IntelliComm II Interface Adapter For use with IntelliFlo and IntelliPro pumps IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS S...

Page 2: ...demarks of Hayward Industries Inc Jandy and AquaLink are registered trademarks of Jandy Industries Inc Polaris is a registered trademark of Zodiac Pool Systems Inc Unless noted names and brands of oth...

Page 3: ...the IntelliFlo pump s speed or flow Note If more than one terminal input is active the highest input number GPM RPM 4 will take priority regardless of the pump setting A four screw terminal connector...

Page 4: ...rminal Connects to the pump via a two pin 50 ft communication cable P N 350122 provided with the pump Also connects to a 9 24VDC 200mA power source automa tion control system circuit board Four 9 24V...

Page 5: ...iagram RS 485 COMMUNICATION CABLE 22 AWG PWR BLK YLW GRN RED GPM RPM 1 9 24V DC AC YLW GRN RELAY 4 RELAY 3 RELAY 2 RELAY 1 9 24V DC AC Pentair Water Pool and Spa Automation Control Board GND RED BLK P...

Page 6: ...from RJ12 to IntelliComm II Red PWR screw terminal Note To avoid circuit board damage DO NOT connect the RED andYELLOW wires together to Red PWR terminal leave RED UNCONNECTED see page 6 2 Connect RJ1...

Page 7: ...SOL POOL EHTR POOL SOL SPA SOL GRN RED TEMPERATURE SENSORS SPA HEAT PHONE CONTROLS POOL FLR CLN AUX VLV CNTRL AUX VLV TO CONTROL PANEL RED BLK GRN YLW RED PRGM 4 PRGM 3 PRGM 2 PRGM 1 9 24V DC AC RS485...

Page 8: ...L RED NOT CONNECTED BLK GRN YLW RED PRGM 4 PRGM 3 PRGM 2 PRGM 1 9 24 VDC RS485 RS 485 PIN 3 GRN PIN 2 YLW TO PUMP RJ12 ADAPTER TO COM PORT LX100 use black plug IntelliFlo pump LX 100 ONLY YLW GND PWR...

Page 9: ...8 CAUTION DO NOT SHORT PINS OF RELAY SOCKETS GND HLMP HBST SPA POOL REM1 REM2 REM3 REM4 REM5 REM6 18 10 24 PART PC LX3830 COMPOOL 11010B SPA 2SPD SFLT PFLT AUX1 AUX2 AUX3 AUX4 AUX5 AUX6 FREEZE I L SY...

Page 10: ...lo pump BLK GND YLW GRN RED 9 24V DC PRGM 4 PRGM 3 PRGM 2 PRGM 1 9 24V DC AC PWR GND From Compool circuit board From Compool circuit board Connect to Compool circuit board see page 4 Choose the functi...

Page 11: ...face Adapter Installation and User s Guide 9 BLACK GND Swim Master LX20 CP2000 and Time Master LX10 BLACK GND RED 24 VDC BLACK GND RED 24 VDC CP1000 RED 24 VDC BLACK GND RED 24 VDC CP2020 BLACK GND RE...

Page 12: ...lay circuit on the Jandy circuit board Typically GPM RPM 1 connects to the output Filter Pump relay terminal plug However Jandy auxiliary relay circuits can be connected to any of the four input termi...

Page 13: ...m II mounted inside low voltage compartment of Power Center RS485 YLW GRN BLK YLW GRN RED PRGM 4 PRGM 3 PRGM 2 PRGM 1 9 24V DC AC GND PWR GND CHOOSE FUNCTION for connection to IntelliComm II RELAY 4 I...

Page 14: ...e upper and lower relay bracket and remove the brackets 4 Attach wires to the FILTER PUMP relay screws terminals Loosen the two top relay terminal screws with attached wires Using the provided auxilia...

Page 15: ...IntelliComm II Interface Adapter Installation and User s Guide 9 24V DC AC 9 24 VDC 13 IntelliComm II to Hayward Pro Logic Control System Connection Diagram...

Page 16: ...cting AUX cables 2 Connect the auxiliary cables provided in kit from the IntelliComm II input terminals GPM RPM 1 2 3 and 4 to any control output or auxiliary relay circuit on the Polaris circuit boar...

Page 17: ...LAY3 RELAY2 RELAY1 9 24V DC AC PWR GND From Polaris circuit board From Polaris circuit board Connect to Polaris circuit board Choose the function on the Polaris circuit board HP1 HP8 VLV1 VLV 6 Polari...

Page 18: ...its filter cycle This is done on the IntelliFlo keypad under Menu Filter Address 1 is the default address for the IntelliFlo VF The IntelliComm II will only communicate with address 1 The pump s Addre...

Page 19: ...ets a command to run a speed from the IntelliComm II it will run the new commanded speed and the LED above the new speed will be illuminated When the command from the IntelliComm II has stopped the pu...

Page 20: ...page 10 for the IntelliFlo VF steps 1 through 12 However there is one difference The IntelliFlo VS SVRS does not have any default Schedules so it is not necessary to deactivate any schedules so it wil...

Page 21: ...c x E s a h n a f r o t o m e h t e r u s n E 1 n o i t a l i t n e v r o f a e r a e t a u q e d a o t d e e p s r e h g i h a t a r o t o m n u R 2 w o l f r i a g n i l o o c e v o r p m i 7 m r a...

Page 22: ...t board Be careful not to touch the circuit board components Hold the circuit board by the edges Place the circuit board aside Drill two mounting screws holes for the back cover 3 Cut out the template...

Page 23: ...IntelliComm II Interface Adapter Installation and User s Guide IntelliComm II Back Cover Template Cut Out Cut Out...

Page 24: ...IntelliComm II Interface Adapter Installation and User s Guide P N 521033 Rev C 521033...

Reviews: