EasyTouch
®
/IntelliTouch
®
SCG Power Supply Replacement Parts Installation Guide
IntelliChlor
®
SCG Power Supply Replacement Parts:
Removal and Installation
To remove the EasyTouch/IntelliTouch load center high voltage panel:
1.
SWITCH OFF AC POWER
AT THE MAIN HOUSE PANEL CIRCUIT
BREAKER
before removing the high voltage panel from the
load/power center.
2.
Unlatch the front door and open the door.
3.
Loosen the two retaining screws securing the high voltage front panel.
Remove the panel from the load/power center.
Read Safety Precautions and Important Instructions (page 1). Before
attempting any electrical wiring, be sure to read and follow Safety
Instructions. Wiring should only be performed by a qualified
professional.
WARNING!
When installing electrical products in the EasyTouch/
IntelliTouch load/power center, basic precautions should always
be followed, including the following:
DANGER: RISK OF ELECTRIC SHOCK, WHICH CAN
RESULT IN SERIOUS INJURY OR DEATH.
Before
attempting removal and installation of replaceable parts in
the EasyTouch/IntelliTouch load/power center, be sure that
all power to the circuit supplying power to the load/power
center is disconnected/turned off at the main house panel
circuit breaker.
Load Center Parts Removal to access SCG replacement parts
The following procedure describes how to remove the EasyTouch/IntelliTouch
load center parts to access the SCG transformer, circuit board and connection
cable.
Introduction
This manual describes how to remove and install the EasyTouch and
IntelliTouch IntelliChlor Salt Chlorine Generator (SCG) replacement
parts.
Summary Installation Steps
•
Before removing and replacing part first switch OFF the main
power to the EasyTouch/IntelliTouch load center.
•
To access the SCG transformer, SCG circuit board and connection
cable, parts of the EasyTouch/IntelliTouch load center must first be
removed. Refer to “
Load Center Parts Removal
”, on page 1.
•
After replacing the SCG parts, switch the power on to the
EasyTouch/IntelliTouch load center and verify that the GREEN
SCG circuit board power LED is on.
1