background image

EasyTouch

®

/IntelliTouch

®

 SCG Power Supply Replacement Parts Installation Guide

i

SERIOUS BODILY INJURY OR DEATH CAN RESULT IF THIS
PRODUCT (UNIT) IS NOT INSTALLED AND USED
CORRECTLY.

INSTALLERS, POOL OPERATORS AND POOL OWNERS
MUST READ THESE WARNINGS AND ALL INSTRUCTIONS
BEFORE USING THIS PRODUCT. This Guide provides installa-

tion and operation instructions for the product. Consult

Pentair Water Pool and Spa, Inc. with any questions regarding

this product.

This product is intended for use in swimming pool applications
only.

Most states and local codes regulate the construction, installa-
tion, and operation of public pools and spas, and the construc-
tion of residential pools and spas.  It is important to comply with
these codes, many of which directly regulate the installation and
use of this product. Consult your local building and health codes
for more information.

IMPORTANT NOTICE - Attention Installer: 

This Installation

Guide (“Guide”) contains important information about the
installation, operation and safe use of this product. This Guide
should be given to the owner and/or operator of this equipment.

Attention User: 

This Guide contains important information that

will help you in operating and maintaining this product. Please
retain it for future reference.

Head

Body

U

pp

er

A

rm

Uppe

r

Arm

Leg Joint

Leg

 J

oint

Leg Joint

Le

g J

oin

t

Head

Body

U

pp

er

A

rm

Leg Joi

nt

Leg

 J

oint

Leg Joint

Le

g J

oin

t

This product is designed and manufactured for safe and reliable
service when installed, operated and maintained according to the

information and installation codes referred to in this Guide. This is a safety alert
symbol. When you see this symbol in this manual or on the product, look for one
of the following signal words; 

DANGER

WARNING

,

 CAUTION

 and 

NOTICE

and comply with the information. Be alert to the potential hazard. Ensure 

to read

and comply with all of the warnings and cautions in this manual.

IMPORTANT WARNING AND SAFETY INSTRUCTIONS

EasyTouch and IntelliTouch replaceable parts must be installed
by a licensed or certified electrician or a qualified pool
professional in accordance with the National Electrical Code
(NEC), NFPA 70 or the Canadian Electrical Code (CEC), CSA
C22.1. All applicable local installation codes and ordinances
must also be adhered to. Improper installation will create an
electrical hazard which could result in death or serious injury to
pool users, installers or others due to electrical shock, and may
also cause damage to property.

Before installing this product, read and follow all safety warning notices and
instructions which are included. Failure to follow safety warnings and instructions
can result in severe injury, death, or property damage. Call (800) 831-7133 for
additional free copies of these instructions.

Risk of Electrical Shock or Electrocution!

Summary of Contents for IntelliChlor SCG

Page 1: ...s Installation Guide Installation Guide IntelliChlor Salt Chlorine Generator SCG Replacement Parts For EasyTouch IntelliTouch Pool Spa Control System with IntelliChlor SCG IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS ...

Page 2: ...ved 1620 Hawkins Ave Sanford NC 27330 919 566 8000 10951 West Los Angeles Ave Moorpark CA 93021 800 553 5000 EasyTouch IntelliTouch IntelliChlor and Pentair Water Pool and Spa are trademarks and or registered trademarks of Pentair Water Pool and Spa Inc and or its affiliated companies in the United States and or other countries Unless noted names and brands of others that may be used in this docum...

Page 3: ...int Leg Joint Le g Jo int H e a d B o d y U p p e r A r m L e g J o i n t L e g J o i n t L e g J o i n t L e g J o i n t This product is designed and manufactured for safe and reliable service when installed operated and maintained according to the information and installation codes referred to in this Guide This is a safety alert symbol When you see this symbol in this manual or on the product l...

Page 4: ...SERIOUS INJURY OR DEATH Before attempting removal and installation of replaceable parts in the EasyTouch IntelliTouch load power center be sure that all power to the circuit supplying power to the load power center is disconnected turned off at the main house panel circuit breaker Load Center Parts Removal to access SCG replacement parts The following procedure describes how to remove the EasyTouc...

Page 5: ...ol to allow access the low voltage compartment behind the control panel 5 After removal and installation procedures are complete Close the control panel and secure with the two retaining screw Reinstall the high voltage panel and secure with the two retaining screw Close and latch the front door Load Center front view front door and high voltage panel removed Control panel fold down to access circ...

Page 6: ... the two push rivets previously removed 4 Route the cable up through side of the enclosure into the low voltage compartment Connect the cable connector to the SCG circuit board Low voltage compartment 12 SCG cable circuit board connector Before removing and installing the SCG circuit board first be sure to switch OFF the main AC power to the load power center Connector socket nut To IntelliChlor c...

Page 7: ... terminal lead to the enclosure base 1 Removal Remove the three 3 screws securing the SCG circuit breaker bracket to enclosure to gain access to the four 4 circuit breakers and wiring 2 Installation To replace circuit breaker bracket reverse removal instructions above Be sure to reattach SCG circuit board GREEN GROUND lead if present Before removing and installing the circuit breaker assembly firs...

Page 8: ...r wire 1 4 quick disconnect onto the rear of the 12 A circuit breaker 4 Connect the other RED transformer wire 3 16 quick disconnect onto the circuit board terminal 5 Install the circuit breaker bracket onto the enclosure and secure with two 8 32 x 3 8 screws 6 Secure the green circuit board ground wire to the enclosure with 8 32 x 3 8 screw 7 Connect the transformer primary AC wires as required S...

Page 9: ... 8 32 x 3 8 Circuit Breaker Circuit Board Screw 8 32 x 7 8 Tighten 10 lb in max SCG Transformer primary AC wires see label on transformer and page 6 for connection information Ground Wire Screw Circuit Breaker Bracket Power Center Transformer Connections CAUTION Do not overtighten rectifier mounting screw Tighten 10 lb in max SCG Transformer primary AC wires see label on transformer and page 6 for...

Page 10: ...nd SCG circuit board SCG Circuit Breaker 12A Ground Wire Screw Circuit Breaker Bracket SCG Power Cable COM Port connector To EasyTouch IntelliTouch Circuit Board Transformer primary AC wires Circuit Board 8 32x7 8 Screw Tighten 10 lb in max Red Circuit Breaker Wire 7 CAUTION Do not overtighten rectifier mounting 10 32x3 4 screw Tighten 10 lb in max RED transformer wire 3 16 quick disconnect ...

Page 11: ...e PUMP SIDE OF THE MAIN FILTER PUMP RELAY located in the load power center This ensures that the IntelliChlor cell produces chlorine only when the main filter pump is on This method does not require a ground fault circuit interrupter GFCI to protect the circuit IntelliChlor SCG Power Supply Replacement kit Contents Description Part Number SCG Transformer P N 521299 SCG Circuit Board P N 521091 SCG...

Page 12: ...EasyTouch IntelliTouch SCG Power Supply Replacement Parts Installation Guide P N 521093 Rev A 521093 ...