background image

 
 

 

 

 

 

USER MANUAL 

 

 

 

 

 

 

 

 

 

 

 

 

PowerWalker 

VFI 1000-2000-3000 TG 

VFI 1000-2000-3000 TGS 

 

 

Summary of Contents for VFI 1000 TG

Page 1: ...USER MANUAL PowerWalker VFI 1000 2000 3000 TG VFI 1000 2000 3000 TGS ...

Page 2: ...9 4 2 LCD description 10 5 Connection and Operation 13 5 1 Inspection 13 5 2 Connection 13 5 3 Battery charge 16 5 4 Turn on the UPS 16 5 5 Test function 16 5 6 Turn off the UPS 17 5 7 Audible alarm mute function 17 6 Operating Mode for All Models 18 6 1 Line mode 19 6 2 Battery mode 20 6 3 Bypass mode 21 6 4 No Output mode 21 6 5 EPO Emergency Power Off 22 6 6 ECO mode Economy mode 22 6 7 CVCF mo...

Page 3: ...nvironment 32 10 3 Typical backup time Typical values at 25 C in minutes 33 10 4 Dimensions and weights 33 11 Communication Port 34 11 1 USB Optional and RS 232 Communication Ports 34 11 2 USB for HID power device 34 11 2 AS400 Interface Option 34 11 2 CMC Interface Option 34 11 2 NMC Interface Option 34 12 Software 35 Appendix Rear panel 36 ...

Page 4: ...ppliances or items of equipment which would overload the UPS e g laser printers etc to the UPS output Place cables properly to avoid someone treaded or tripped over them Assure to connect with the earth reliably Connect the UPS only to a socket outlet which is earthed shockproof type The building wiring socket outlet shockproof socket outlet must be easily accessible to close to the UPS With the i...

Page 5: ... socket during operation the grounding for the UPS and all loads connected will be disconnected The UPS features its own internal current source batteries You may be electric shocked when you touch the UPS output sockets or output terminal block even if the UPS is not connected to the building wiring socket In order to fully disconnect the UPS first press the OFF button to turn off the UPS and the...

Page 6: ...ries must be replaced only by qualified personnel Caution risk of electric shock The battery circuit is not isolated from the input voltage Hazardous voltages may occur between the battery terminals and the ground Verify that no voltage is present before servicing Batteries have a high short circuit current and pose a risk of shock Take all precautionary measures specified below and any other meas...

Page 7: ...fuse only by a fuse of the same type and of the same amperage in order to avoid fire hazards Do not dismantle the UPS except the qualified maintenance personnel 1 4 Transport Please transport the UPS only in the original packaging to protect against shock and impact 1 5 Storage The UPS must be stockpiled in the room where it is ventilated and dry ...

Page 8: ...egory C2 Harmonic Current IEC EN 61000 3 2 Voltage Fluctuation and Flicker IEC EN 61000 3 3 EMS ESD IEC EN 61000 4 2 Level 3 RS IEC EN 61000 4 3 Level 3 EFT IEC EN 61000 4 4 Level 4 SURGE IEC EN 61000 4 5 Level 3 4 CS IEC EN 61000 4 6 Level 3 MS IEC EN 61000 4 8 Level 3 Voltage Dips IEC EN 61000 4 11 Low Frequency Signals IEC EN 61000 2 2 ...

Page 9: ... 6 2 Description of Commonly Used Symbols Some or all of the following symbols may be used in this manual It is advisable to familiarize yourself with them and understand their meaning ...

Page 10: ...ce free batteries power the inverter This manual covers the UPS listed as follows Please confirm whether it is the model you intend to purchase by performing a visual inspection of the Model No on the rear panel of the UPS The Model List Item Model name Power Rating Model type Model description Other 1 VFI 1000 TG 1000VA 900W Tower Standard model Single Phase input Single Phase Output 2 VFI 1000 T...

Page 11: ... 8 UPS Block Diagram ...

Page 12: ...on an acoustic alarm can be deactivated in the battery mode By short touch this Button all acoustic alarms can be deactivated in all modes Do the battery test By pressing this Button the UPS can do the battery test in the Line mode or ECO mode or CVCF mode OFF Button When mains power is normal the UPS system switches to No output or Bypass mode by pressing OFF Button and the inverter is off At thi...

Page 13: ...le enable and operating mode in No output or Bypass mode Battery Ah Battery remain time display disable enable and Charger current in all mode could be selected by pressing Select Button and confirmed by pressing Enter Button Enter Button 4 2 LCD description Figure 4 2 The LCD Display LCD icon Function Display Function Input Information It indicates input voltage frequency value which are displaye...

Page 14: ...load level Every grid represents the level of 20 One grid would be displayed if the level is 0 20 Battery Information It indicates the battery capacity Every grid represents the capacity of 20 Mode Fault Warning Information It Indicates the operating mode or Fault kind or Warning kind or battery remain time several warning kinds at the same time could be displayed alternately Else It indicates the...

Page 15: ...ting string or fault string is presented but the warning if several warning happen at the same time they can be displayed on the LCD alternately And the normal operating mode string and the warning string would be shown circularly Once one fault is come forth all previous warnings and the fault string would be shown circularly Normal operating mode Code No output mode STbY Bypass mode bYPA Line mo...

Page 16: ...tion If the UPS is connected via the power cord please use a proper socket with protection against electric current and pay attention to the capacity of the socket The UPS System has an input breaker on the standard cabinet 2 UPS Output Connection The output sockets and types of the UPS are shown below Model No Output Socket SCHUKO pcs Output Socket IEC pcs VFI 1000 TG 3 Schuko 4 C13 The system ma...

Page 17: ...nnection of batteries more than or less than required will cause abnormality or permanent damage One Standard type battery connector on the rear panel is used for connecting the battery pack The battery connection procedure is very important Any incompliance may result in the risk of electric shock Therefore the following steps must be strictly complied with Prepare the battery cable with Standard...

Page 18: ...n the rear panel Once the connector is closed with a wire the UPS will stop output until EPO status is reset Disable EPO status Enable EPO status Normally close Normally EPO connector is closed with a wire on the rear panel Once the connector is open the UPS will stop output until EPO status is disabled The Caution A DC breaker must be connected between the UPS and external battery if no used stan...

Page 19: ...ting Even though mains power is not connected to the UPS the UPS still can be turned on by just simply pressing on button continuously for more than 1 second with external batteries connected the UPS will get into the Battery mode and the LCD screen will indicate the state of the UPS Note The default setting for bypass mode is no output after UPS is connecting mains power and breaker is turned on ...

Page 20: ...rm is too annoying in battery mode the audio alarm is able to mute by press ON button continuously for more than 1 second Moreover the audio alarm will be active again when the battery reaches low status for reminding that UPS output power will shut down soon If the audio alarm is too annoying in bypass mode the audio alarm is able to mute by press OFF button continuously for more than 1 second Th...

Page 21: ...ircularly Once one fault is come forth then all previous warnings would not be shown again but only the fault string is presented Warning Fault Code Table 6 1 Warning String Site fail SITE Fan fail FANF Battery over voltage over charged HIGH Battery low bLOW Charge fail CHGF Inverter temperature high TEPH Battery open bOPN NO Status Alarm 1 Battery mode Beep once every 4 sec 2 Battery mode with ba...

Page 22: ... temperature fault OVTP Inverter Volt Low INVL Inverter Volt High INVH Bus volt over bUSH Bus volt Low bUSL Bus short bUSS Inverter NTC open NTCO Emergency Power Off EPO 6 1 Line mode The LCD display in Line mode is shown as figure6 1 The information about the mains power the battery level the UPS output and the load level will be displayed The LINE string indicates UPS working in Line mode ...

Page 23: ...tery mode If the function of battery remain time is set to enable the bATT string and battery remaining time in unit Min or Sec would display in turn every 2s When the UPS is running in battery mode the buzzer beeps once every 4 seconds If the ON button on the front panel is pressed for more than 1 second the buzzer will stop beeping in silence mode Press the ON button once again for more than 1 s...

Page 24: ...eep once every 2 minutes in bypass mode The bYPA string indicates UPS working in the bypass mode Figure 6 3 The Bypass mode 6 4 No Output mode The LCD display in No output mode is shown as figure6 4 The information about the mains power the battery level the UPS output and the load level could be displayed The STbY string indicates UPS working in the No output mode Figure 6 4 The No output mode ...

Page 25: ...ce the mains power is loss or out of range the UPS will transfer to battery mode and the load will be supplied continuously by the battery 1 ECO mode can be enabled through the LCD setting or the software Winpower etc 2 The transfer time of UPS output from ECO mode to battery mode is less than 10ms It is suggested that takes account of application for some sensitive load 6 7 CVCF mode CVCF Constan...

Page 26: ... and battery remaining time function in all mode could be set directly through LCD module In bypass or no output mode pressing the Enter button on the LCD panel for more than 1 second to enter setting mode The LCD display is shown in the following figure7 1 The string OPV that stands for output voltage 230Vac indicates the existing output voltage is 230Vac if you want to set output voltage press t...

Page 27: ...ny time Bypass status can be selected in 000 or 001 Here 000 means Bypass Disable 001 means Bypass Enable The UPS would turn to bypass mode in several seconds if Bypass Enable is selected and turn to no output mode in several seconds if Bypass Disable is selected Operating mode can be selected in UPS ECO CVF Here UPS means the normal online mode ECO means the high efficiency mode and CVF means the...

Page 28: ...ry test mode the battery remaining time in unit Min or Sec and string bATT would display on LCD in turn every 2s An example for changing the Operating mode from normal mode to converter mode through the LCD display Step 1 OPV after pressing the Enter button Step 2 OPF after pressing the Select button ...

Page 29: ... 26 Step 4 MOdE after pressing the Select button UPS is flickering after pressing the Enter button Step 5 ECO flickering after pressing the Select button Step 3 bYPA after pressing the Select button ...

Page 30: ... 27 Step 6 CVF flickering after pressing the Select button Press the Enter button Short touch Enter button exit setting mode ...

Page 31: ...ower supply 1 No input voltage 2 Breaker open 1 Check building wiring socket outlet and input cable 2 Check the Breaker No Communication data 1 RS232 wire is not matched 2 USB wire is not matched 1 check or change the RS232 wire 2 check or change the USB wire Emergency supply period shorter than nominal value 1 Batteries not fully charged 2 Batteries defect 1 Charge the batteries until the Batteri...

Page 32: ...harge is broken Notify dealer bUSH Bus high UPS internal fault Notify dealer bUSL Bus low UPS internal fault Notify dealer bSFT Bus soft start fail UPS internal fault Notify dealer bUSS Bus short UPS internal fault Notify dealer TEPH Inverter temperature high Inside temperature of the UPS is too high Check the ventilation of the UPS check the ambient temperature ITPH Inner Ambient temperature high...

Page 33: ...her some loads are failed SITE Site fail Phase and neutral conductor at input of UPS system are reversed Rotate mains power socket by 180 or connect UPS system EPO EPO active EPO function is enabled Plug into the EPO switch Please have the following information at hand before calling the After Sales Service Department 1 Model number serial number 2 Date on which the problem occurred 3 LCD display ...

Page 34: ...arts 9 2 Storage If the batteries are stored in temperate climatic zones it is recommended to recharge those batteries every three months for 1 2 hours It is highly suggested to shorten the recharging intervals in every two months at locations where subjects to high temperatures ...

Page 35: ...50 60Hz Wave form sinusoidal Note the active power is defined in rated voltage input BATTERIES Model No 1000 TG 1000 TGS 2000 TG 2000 TGS 3000 TG 3000 TGS Voltage 24V 24V 48V 48V 72V 72V Capacity 9Ah 5Ah 120Ah 9Ah 5Ah 120Ah 9Ah 5Ah 120Ah Note the Capacity of external batteries can be set to 300Ah maximum but it may need more time to fully charge the batteries 10 2 Operating Environment Ambient Tem...

Page 36: ...VFI 2000 TGS 16 30 Base on 1EBM 45 00 Base on 1EBM VFI 3000 TG 4 00 11 30 VFI 3000 TGS 11 00 Base on 1EBM 28 00 Base on 1EBM 10 4 Dimensions and weights Model No Dimensions W H D mm Net Weight kg VFI 1000 TG 144 229 345 9 3Kg VFI 1000 TGS 102 229 345 3 7Kg VFI 2000 TG 190 330 393 22 2Kg VFI 2000 TGS 102 330 393 5 4Kg VFI 3000 TG 190 330 393 22 2Kg VFI 3000 TGS 102 330 393 5 4Kg ...

Page 37: ...ser can configure the alarm action in the event of low battery such as shutting down the computer automatically UPS with this feature is also ideal as a back up power for NAS Network Attached Storage 11 2 AS400 Interface Optional It owns isolated dry contact relay outputs for UPS status such as Mains Utility failure Battery low UPS alarm OK or on Bypass and so on To see more detail about the inter...

Page 38: ... control any UPS on the same LAN no matter how far from the UPSs Installation procedure 1 Go to the website http winpower powerwalker com 2 Choose the operation system you need and follow the instruction described on the website to download the software 3 When downloading all required files from the internet enter the serial No 511C1 01220 0100 478DF2A to install the software When your computer re...

Page 39: ... 36 Appendix Rear panel 1000 TG S Back View of Schuko 2000 TG S Back View of Schuko ...

Page 40: ... 37 3000 TG S Back View of Schuko 1000 TG S Back View of IEC ...

Page 41: ... 38 2000 TG S Back View of IEC 3000 TG S Back View of IEC 11 04 2016 614 02071 00 ...