background image

4

ENGLISH

sure that a first-aid kit is to hand.

In some cases, the pump and the pumping medium may be hot 
and could cause burns. 
For installations in areas subject to explosion hazards, special 
regulations apply! 

USE

The  Hebefix  100  tank  is  a  drainage  pump  station  which  can 

be equipped with the pumps U3KS, U3KS spezial, U5KS, U6K 
ES+DS, US 62 up to US 103 ES+DS. The operating conditions 
according to the manual of the pump must be observed. 

CAUTION!

 The Hebefix is designed for usual domestic draina

-

ge water, according to EN 12056. In some countries it must not 
be used for pumping sewage water from lavatories. 

The allowed temperature of the pumped medium is 35° C (short 
time period 60° C).

The Hebefix 100 has 4 lateral marked connection branches on 

both sides for tubes with Ø 50 mm or Ø 110 mm to connect a 
wash basin, a washing machine or a dishwasher. In connection 

with  a  special  float  a  shower  can  be  connected  as  well.  The 

pressure tube can be installed right or left handed through the 
upper connection pieces of the tank casing. The marked open-
ing has to be drilled at site. 

The  tank  is  serially  fitted  with  a  ventilation  valve  in  the  lid, 

which closes with rising water level. If the  marked connection 
in the cover will be opened, the vent pipe to the roof can be 
connected from the top. Alternatively it can be connected at 
the side, in this case, ventilation valve can be closed with the 
closing plug ø22,3.

Ventilation.

Sumps and tanks for the drainage of a cellar should be covered 
and, if necessary, specially ventilated (EN 12056).

Ventilations with additional activated carbon filters decrease 

annoyance caused by bad smell.

Extent of delivery 

Above ground tank Hebefix 100 (tank with sealed screwed lid), 
1  hose  clamp,  2  fillister  head  screws,  3  cap  screws  ,  3  caps 

(black), 1 ball Ø 25,4 mm, socket plug DN 50, 1 ventilation seal, 1 

plug-in seal d 50 x D59, 1 activated carbon filter, 1 closing plug.

Bag with: bushing 50x1 1/2“, 2 octagon nuts, 2 PE-bearing rings, 
threaded bushing, connection joint, 2 elbows 90°, 2 pipes ø 
50x100, elastic connection 1 1/2“, 2 hose clamps 1 1/2“, bushing 
40x 1 1/4“, 4 plug-in seals d50 x D59, closing plug ø22,3, 2 wood 

screws, 2 washers 2 plugs, 2 fastening clamps, 2 fillister head 

screws.
Bag with : 1 non-return valve DN 40, 1 collar DN 100, 2 hose 
clamps 4“, 1 manual.

ELECTRICAL CONNECTION

Please pay attention to the operating instructions of the in-
stalled pump.

MOUNTING

The installation of the lifting unit should be made in accordance 
to the guide lines for faeces free sewage EN 12056-4. The tank 
must be easily accessible for maintenance and service. The in-
stallation must guarantee the reliable operation.

The Hebefix 100 should be installed as shown at the end of the 

manual. In accordance to EN 12056 the pressure pipe must be 
taken in a loop over the local back-up level and secured with a 

reflux valve. The reflux valve1 1/2 inch (Z-53.4-369) is enclosed. 

Each drain connection (e.g. washing machine, dish washer ...) 
must have a siphon trap. 

Installation

1. Take the plugs and the screws out of the cable cover. Re-
move the cover itself. Seize into the recessed grips, lift the 
cover off the tank and withdraw the accessories.
U3KS, U5KS and U6KS: Screw the 1 1/4“ plastic elbow (extend 
of pump unit) with sealing tape handtight onto the pressure 
branch of the pump. Screw the reducing nipple 40 x 1/4“ into 
the elbow.
US 62 bis US 103 ES+DS: Screw one of the 1 1/2“ plastic elbow 
with pipe piece Ø 50 x 100 with sealing tape into the pressure 
branch of the pump. 
Next, component follows the elastic connection. For the fur-
ther pressure pipe construction see drawing page 2. 
2. Open the required connection pieces for the pressure out-
let, the inlet(s) and if required for the ventilation at the marked 
points, by cutting or drilling.

CAUTION!

 Do not damage the raised and flat face ! and push 

the enclosed plug-in seals into the opened connection bran-
ches.

Connection of the inlet pipe DN 100: connect the spigot end of 
the DN 100 pipe with the elastic connection DN 100 and the 2 
hose clamps 4” to the required tank socket. For additional con-
nections in DN 100 elastic connections and hose clamps are 
available as accessories.

3. Put the pump with the pressure pipework into the floor lock 

of the tank and push the pressure tube through the bore hole. 
Fasten the pipework with the 1 1/2“ octagon nut from outside. 
The tank can now be connected with the external pipework.

4. Pull the pump cable with the plug
through the Ø 70 mm hole in the cover. 
Swing open the seal plug, insert the 
pump cable and push the plug into the 
provided hole in the cover. The cable in 

the tank must be so short that the float 

moves free. For the outer cable lenght 
think about the installation of the cover 
and necessary maintanance. 

5. Remove and 

unwrapp

 the activated carbon filter and put it 

over the ventilation hole between the terminal plates. In case 
of ventilation to the roof press the enclosed plug into the ven-