background image

12

  

     056255661 (02-01-22)

MOTOR DATA CHART

H.P.

SPEED

VOLTS

PHASE STACK HEIGHT

WINDING RESISTANCE IN OHMS

MAX. AMPS

LOCKED 

ROTOR AMPS

MAIN 

BLACK TO 

WHITE

START - 1Ø 

BRN. TO BRN. OR 

PURPLE

WHITE TO 

RED

BLACK TO RED - 3Ø

1/2

3450

115

1

1-5/8

.9/.8

14.7

-

12.1

29.6

230

9.8

19.7

6.0

15.0

1

230

3.0/2.6

16/14

9.3

19.0

208/230

3

2-1/2

5.3

5.3

5.3

6.6/6.0

29.0

575

33.1

33.1

33.1

2.4

11.6

SPECIFICATIONS

PUMP SPECIFICATIONS

MODEL NUMBER

ENGINEERING #

HP

VOLTS

PHASE/ 
CYCLES

DISCHARGE 

SIZE

SWITCH TYPE

APPROX 

CORD 

LENGTH

WT. LBS

SHEF100SA2 20

528680007

1

230

1/60

2"

Manual

20'

83

SHEF100SM2 20

528680017

1

230

1/60

2"

Manual

20'

83

SHEF100SM3 20

528680027

1

230

3/60

2"

Manual

20'

83

SHEF100SM5 20

528680047

1

575

3/60

2"

Manual

20'

83

SHEF50SA1 20

528670007

1/2

115

1/60

2"

Manual

20'

73

SHEF50SA2 20

528670027

1/2

230

1/60

2"

Manual

20'

74

SHEF50SM1 20

528670017

1/2

115

1/60

2"

Manual

20'

73

SHEF50SM2 20

528670037

1/2

230

1/60

2"

Manual

20'

74

SHEF50SM5 20

528670067

1/2

575

3/60

2"

Manual

20'

74

Summary of Contents for SHEF100S

Page 1: ...SUBMERSIBLEEFFLUENTPUMPS SHEF50S SHEF100S pentair com INSTALLATION OPERATIONMANUAL 056255661 02 01 2022 2022 Pentair All Rights Reserved...

Page 2: ...2 056255661 02 01 22 TABLEOFCONTENTS Safety Instructions 3 Description 4 Installation 5 Diagrams 6 Maintenance 9 Specifications 11 Repair Parts List 14 Warranty 16...

Page 3: ...Never operate the pump in an explosive environment Arcing from the motor brushes switch or excessive heat from an improperly cycled motor may cause an explosion ELECTRICAL SAFETY DANGER Hazardous volt...

Page 4: ...r SOFTWARE for designing PRESSURE SEWER SYSTEMS This gives pipe sizes to use and gives exact flow from any pump or group of pumps in the system when operating simultaneously This design DISK for IBM o...

Page 5: ...her single or three phase must turn counterclockwise when looking into pump inlet If uncertain of rotation TURN OFF POWER and lift pump from basin with cord connected and lay pump on side so impeller...

Page 6: ...L MOUNTING BRACKET SST 45 AS REQ D 30 DIA BASIN COVER VALVE EXTENSION HANDLE 18 1 1 2 CONDUIT REQ D 30 DIA CONCRETE WELL INLET HUB AS REQ D PUMP OFF LEVEL EFFLUENT PUMP LIFT OUT ROPE 2 DISCHARGE 2 GAT...

Page 7: ...JUNCTION BOX STRUCT PLASTIC AS REQ D AS REQ D 30 DIA BASIN COVER 2 UNION PVC 18 1 1 2 CONDUIT REQ D 30 DIA CONCRETE WELL INLET HUB AS REQ D PUMP OFF LEVEL EFFLUENT PUMP LIFT OUT ROPE 2 DISCHARGE 2 GAT...

Page 8: ...48 BASIN COVER W HINGED HATCH LOCK HASP EPOXY COATED 1 4 STEEL VALVE EXTENSION HANDLE 18 2 CONDUIT REQ D 48 DIA CONCRETE WELL INLET HUB AS REQ D PUMP OFF LEVEL EFFLUENT PUMP LIFT OUT ROPE 2 DISCHARGE...

Page 9: ...ord bushing to be replaced and remove cord assembly from housing Be sure remaining terminals are secure on the wires Replace with proper cord with fittings Push cord into the motor housing far enough...

Page 10: ...rn replace 9 Be sure tetraseal gasket is in position replace if worn and reassemble 10 Replace oil in motor housing and seal chamber Use only Hydromatic submersible oil 11 Be sure pump turns freely be...

Page 11: ...20 SHEF50SM5 20 SERIES DIMENSIONS MODEL SERIES INCHES MILIMETERS A B C F SHEF50S 16 8 427 4 09 1 03 12 13 SHEF100s 16 8 427 4 00 1 06 12 5 11 47 291 5 12 130 9 63 245 2 NPT Discharge F A C B PERFORMAN...

Page 12: ...NS PUMP SPECIFICATIONS MODEL NUMBER ENGINEERING HP VOLTS PHASE CYCLES DISCHARGE SIZE SWITCH TYPE APPROX CORD LENGTH WT LBS SHEF100SA2 20 528680007 1 230 1 60 2 Manual 20 83 SHEF100SM2 20 528680017 1 2...

Page 13: ...13 056255661 02 01 22 PAGE INTENTIONALLYLEFTBLANK...

Page 14: ...14 056255661 02 01 22 OIL LEVEL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 2 NPT 23 24 25 26 27 28 REPAIRPARTS LIST...

Page 15: ...Stator Rotor shaft with shell 1 See Chart 18 Bearing ball lower 1 08565A022 19 Seal shaft 1 25370A000 20 Plate brg seal 1 25367D000 21 Gasket tetraseal 7x6 3 4x1 8 1 05014A181 22 Screw cap 5 16 x 1 1...

Page 16: ...res resulting from abuse accident or negligence c to normal maintenance services and parts used in connection with such service d to units that are not installed in accordance with applicable local co...

Reviews: