background image

NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible 
party who maintains the system.

INSTALLATION AND SERVICE MANUAL

SUBMERSIBLE 

SEWAGE PUMP  

RECESSED IMPELLER

ENGLISH: PAGES 2-12

Installation and Service Manual 

NOTE! To the installer: Please make sure you provide 
this manual to the owner of the equipment or to the 
responsible party who maintains the system.

Item # E-03-325  |  Part # 5625-325-1  |  © 2018 Pentair plc.  |  07/09/18 

Models   

MODELS S3HRC, 

S3HVX

*

, S4NRC  

and S4NVX

*

 

*For use in Hazardous Locations  

Class I, Division 1, Groups C & D

HYDROMATIC

S3HRC

Shown

Summary of Contents for S3HRC

Page 1: ...MP RECESSED IMPELLER ENGLISH PAGES 2 12 Installation and Service Manual NOTE To the installer Please make sure you provide this manual to the owner of the equipment or to the responsible party who mai...

Page 2: ...If the lower seal leaks and moisture enters this chamber the moisture would settle to the bottom of the chamber and will complete the circuit between the moisture detectors This circuit must be connec...

Page 3: ...om the factory as 460 volt 3 phase cannot be rewired to any other voltage To Re wire the pump from 230V to 460V 3 phase Only a 230V pump from the factory is considered dual voltage a cord label clearl...

Page 4: ...other pump Notice run lights on panel pumps should alternate on each successive cycle of operation Turn both H O A switches to Off position and allow sump to fill to the override control level Turn bo...

Page 5: ...HEAT SENSORS ARE NOT CONNECTED AS SHOWN IN SERIES WITH CONTACTOR OIL Before refilling chamber with oil air test as described above Refill both chambers with oil as described above Always check all lea...

Page 6: ...S LOCATION ONLY PROBE TEST RESISTOR ON HAZARDOUS LOCATION ONLY PROBE TEST RESISTOR ON HAZARDOUS LOCATION ONLY PROBE TEST RESISTOR ON HAZARDOUS LOCATION ONLY 230 VOLT SINGLE PHASE 200 OR 575 VOLT THREE...

Page 7: ...7 Wiring Diagrams...

Page 8: ...018 Nut 4 18 010270061 Stud 4 19 071310001 Gasket 1 20 105 014034 263 Bolt 3 21 003000001 Seal Ceramic Std 2 006960001 Seal Carbide Opt 1 22 005190011 Washer 1 23 005560031 Bolt 1 24 147690012 Impelle...

Page 9: ...eal Carbide Opt 1 24 107690002 Volute 1 25 005170041 Capscrew 3 26 009750121 Retainer Ring 1 27 107430012 Bearing Housing 1 28 049160001 Upper Seal 1 29 005680071 Capscrew 4 30 002380061 Capscrew S ST...

Page 10: ...7 30 Dia 1 071440092 Impeller 7 20 Dia 1 071440112 Impeller 6 40 Dia 1 071440132 Impeller 5 90 Dia 1 071440142 Impeller 5 50 Dia 1 26 071430012 Volute Case 1 27 001500291 O ring 1 28 009750121 Snap Ri...

Page 11: ...005170081 Capscrew 4 32 24407C223 Stator 1 hp 230 1 60 1150 rpm 1 147152031 Stator 1 hp 200 1 60 1150 rpm 1 24407C225 Stator 1 hp 230 460 3 60 1150 rpm 1 24407C224 Stator 1 hp 200 3 60 1150 rpm 1 2440...

Page 12: ...perate or maintain the unit in accordance with the printed instructions provided b to failures resulting from abuse accident or negligence c to normal maintenance services and parts used in connection...

Reviews: