Safety • Installation
3
5. Risk of explosion and hazardous gas. Septic
tank must be vented in accordance with local
plumbing codes.
do not smoke or use sparkable electrical devices or
flame in a septic (gaseous) or possible septic sump.
If a septic sump condition exists and if entry into
sump is necessary, then (1) provide proper safety
precautions per oSHa requirements and (2) do
not enter sump until these precautions are strictly
adhered to.
do not install pump in location classified as
hazardous per N.E.c., aNSI/NFPa 70- 2001.
6. Know the pump application, limitations and
potential hazards.
7. Wear safety glasses at all times when working with
the pump.
8. Keep the work area clean, uncluttered and properly
lighted - secure all unused tools and equipment.
9. Keep visitors at a safe distance from working area.
10. make the workshop child-proof - with padlocks,
master switches, and by removing starter keys.
11. release all pressure within the system before
servicing any component.
12. Provide a means of pressure relief for pumps whose
discharge line can be shut-off or obstructed.
13. Periodically inspect the pump and system
components. Perform routine maintenance
as required.
14. drain all the liquid from the system before servicing.
California Proposition 65 Warning
This product and related accessories contain
chemicals known to the State of california to cause
cancer, birth defects or other reproductive harm.
Installation
Thank you for purchasing this HYdromaTIc® pump. To
help ensure years of trouble-free operation, please read
the manual carefully.
Before installation, check your local electrical and
plumbing codes. a typical sewage pump installation is
shown below.
Risk of electrical shock and fire.
1. attempting to lift or support the pump by
the power cord can damage cord and cord
connections, expose bare wires, and cause
a fire or electrical shock.
2. Use handle on top of pump for all lifting or
lowering of pump. disconnect the power
to the pump before doing any work on it
or attempting to remove it from the pit.
3. Lifting or supporting the pump by the
power cord will void the warranty.
Risk of electrical shock.
Can burn or kill.
Do not lift pump by
power cord.
WARNING
Cord Lift Warning
Compacted
Sub-base
Backfill
Discharge
Pipe
3620 1110
Check Valve
Plug the Switch
into a Properly
Grounded Outlet
Basin
Finished
Floor
Lid
Do Not Mount
Vertically
Purchase vent and
discharge pipes locally.
Extend vent through roof
or connect to existing vent.
Vent Pipe
Inlet
Pipe
Typical
Sewage
Pump
Summary of Contents for HYDROMATIC SK60 Series
Page 20: ......