Cascade Comfort System  

Introduction 

The Cascade Comfort System is designed to significantly improve the efficiency and 
environmental safety of your nursing care operation and yet have the quality appearance and 
appeal of a home system. However, the benefits designed into the Cascade Comfort System 
will be realized only if the system is operated and cared for properly. The purpose of this 
manual is to provide you with a recommended procedure to help you obtain the maximum 
efficiency and safety from your Cascade Comfort System.  

Symbols and Terms 

 

WARNING

 

The warning symbol identifies important safety messages. Failure to obey a safety warning 
may result in injury to you or to others. 

 

 

C

C

A

A

U

U

T

T

I

I

O

O

N

N

 

The caution heading identifies important maintenance and operation information. Failure to 
obey a caution warning may result in damage to the equipment and may void the warranty. 
 

Left or Right 

 
When the terms “left” or “right” are used with reference to the spa, this means left or right as 
you look at the control panel from the seat end of the spa. 

Technical Description 

The Cascade Comfort Spa is an “Aqua-Aire” bathing system intended for use in nursing 
homes, hospitals, and assisted living facilities to bath residents under the direct supervision of 
trained staff. The system is mainly constructed of gel-coated fiberglass laminate on a powder 
coated steel frame. The spa has an Aqua-Aire system for mixing the water with air. It has a 
disinfecting system to aid in cleaning the spa.  The spa has a locking door on one side for 
access to the spa by the resident. A thermostatic mixing valve controls incoming water 
temperature. Digital temperature read-outs indicate all incoming and spa water temperatures. 
A hand shower sprayer is also provided. 

Summary of Contents for Cascade Comfort 560010-X

Page 1: ...e Operation Daily Maintenance Instructions PENNER PATIENT CARE INC Box 523 101 Grant St Aurora NE 68818 560750 Revision A 12 11 15 1 866 PENNERS 1 866 736 6377 1 800 732 0717 E mail Address pennersale...

Page 2: ...COMFORT SPA CONTROLS 5 CASCADE DOOR 6 LOCKING CASCADE DOOR 6 UNLOCKING CASCADE DOOR 6 SYSTEM PREPARATION BEFORE BATH 7 USING CASCADE COMFORT BATHING SYSTEM 8 BATHING PROCEDURE 8 TRANSFERRING OUT OF C...

Page 3: ...tion information Failure to obey a caution warning may result in damage to the equipment and may void the warranty Left or Right When the terms left or right are used with reference to the spa this me...

Page 4: ...tient weight rating 400 lbs Maximum Upright position to reclined position angle approximately 30 Reclining actuator rating 1 minute ON 9 minutes OFF All temperature read out values are accurate to 2 F...

Page 5: ...ECT JETS 3 HAND SPRAYER ON AUTO OFF 4 FILL SHOWER TEMPERATURE DISPLAY 5 FILL SHOWER TEMPERATURE CONTROL MIXING VALVE 6 SPA TEMPERATURE DISPLAY 7 AQUA AIRE ON OFF 8 TUB FILL ON OFF 9 HAND SHOWER 10 SPO...

Page 6: ...cade Door Figure 2 1 With door handle in the upright position close the door tight against the spa 2 When the door is against the spa push the door handle to the left or down so the door handle is in...

Page 7: ...uch as a washcloth towels and liquids such as shampoo and body wash You are now ready to bring the Resident or Patient to the Bathing Area with your Patient Transfer System or Wheel Chair 2 At the bat...

Page 8: ...st the water temperature by turning the Temperature Control knob to normal bathing temperature 95 to105 degrees Fahrenheit 35 to 41 degrees Celsius 2 When water reaches the overflow push Tub Fill butt...

Page 9: ...he sprayer into the spa not at the resident Press the trigger on the hand sprayer and adjust the mixing valve if needed to the normal bathing range of 95 to 105 degrees Fahrenheit 35 to 41 degrees Cel...

Page 10: ...rain 5 Press and hold the Disinfect Button located on the control panel As the button is held down the properly mixed cleaning solution is running through the air injection system and out all of the a...

Page 11: ...isibly check that the spa was effectively cleaned during the disinfecting procedure If not repeat the procedure 14 If there is a delay of one or more hours before the next bath we recommend using a to...

Page 12: ...nfectant concentrate from damaging their eyes or skin If disinfectant gets on the skin or in the eyes rinse thoroughly with plenty of water Seek medical advice if irritation occurs 2 Perform the Daily...

Page 13: ...door WARNING If during the safety checks you find parts are missing are excessively worn do not function properly or do not meet the recommended safe operating levels do not operate the equipment unt...