CONTENTS 

1.0  USER INSTRUCTIONS - REMOTE CONTROL 

 

 

 

 

 

 

Page 3 

 

1.1  General  

1.2  Manual transmitter 
1.3  Screen setup 

1.4  Setting the time 
1.5  Setting the timer: P1 and P2 (thermostat version only) 
1.6  Igniting the flame (remote control) 

1.7  Possible error messages 
1.8  Setting the flame height / extinguishing the flame 
1.9  Switching the unit off 

1.10  Inserting and replacing batteries 
 

2.0  USER INSTRUCTIONS - MANUAL CONTROL 

 

 

 

 

 

 

Page 6 

 

2.1   Igniting the fire  
2.2   Extinguishing the fire  

2.3   Switching the unit off  

 

3.0  INSTALLATION INSTRUCTIONS 

 

 

 

 

 

 

 

 

Page 7 

 

3.1   General instructions  

3.2   Chimney preparation   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.0   POSITIONING THE APPLIANCE 

 

 

 

 

 

 

 

 

Page 8  

 
4.1   Installation of the flue liner  
4.2  Connecting the gas lines 

4.3  Preparation and installation 
4.4  Fitting the ceramic log set 

4.5   Spillage test 
  

5.0   TECHNICAL DETAILS GV60 

 

 

 

 

 

 

 

 

 

 

Page 9 

 

 
6.0   INSTRUCTIONS FOR MERTIK MAXITROL GV60 GAS CONTROL 

 

 

Page 10   

 

7.0   GAS TECHNICAL DATA 

 

 

 

 

 

 

 

 

 

 

 

Page 11   

 

8.0 TROUBLESHOOTING FLOW CHART MERTIK GV60 

 

 

 

 

 

Page 12

 

 

9.0  PROBLEMS AND POSSIBLE SOLUTIONS

 

  

 

 

 

 

 

 

Page 15 

 
 
APPENDIX 1  DIMENSIONAL DRAWINGS 

 

 

 

 

 

 

 

Page 16 

 
APPENDIX 2  PREPARATION AND INSTALLATION 

 

 

 

 

 

Page 17   

 

APPENDIX 3  CERAMIC LOG SET PLACEMENT 

 

 

 

 

 

 

Page 18 

Summary of Contents for VEGA C7

Page 1: ...INSTALLATION INSTRUCTIONS VEGA C7 CONVENTIONAL FLUE GAS STOVE VC7 REV A 08 17...

Page 2: ...ire 2 3 Switching the unit off 3 0 INSTALLATION INSTRUCTIONS Page 7 3 1 General instructions 3 2 Chimney preparation 4 0 POSITIONING THE APPLIANCE Page 8 4 1 Installation of the flue liner 4 2 Connect...

Page 3: ...rted press the OFF button and small at the same time to toggle between F and 12 hour clock and C and 24 hour clock Wait a moment or press OFF to return to MAN mode 1 4 Setting the time Press large and...

Page 4: ...rner is ignited the flame size will adjust to its maximum height automatically Press the button small on the image of the flame to reduce the height and to switch the burner off Extinguishing the flam...

Page 5: ...nect the new battery and place the whole unit back Close the cover 2 Receiver Carefully remove the entire receiver from the holder Slide the small cover open Remove the batteries from the battery hold...

Page 6: ...e pilot flame is burning through the glass window If the pilot flame is alight keep the metal circle pressed down for another 10 seconds and then let go Turn the manual knob to the ON position The bur...

Page 7: ...umulate Under no circumstances should the Oxypilot be altered or bypassed in anyway If after a period of use the appliance shuts down for no apparent reason the consumer should be informed to stop usi...

Page 8: ...xt open the door of the gas appliance and take all the packaged components out check to make sure they are not damaged or broken Fit the ceramic log set see section appendix 3 page 22 Replace the cast...

Page 9: ...o ignition Gas connection 3 8 External Unit category B11BS Pilot flame SIT 3 flames PAGE 9 Main valve knob Thermocouple c Pressure regulator Ignition connection Pilot gas adjustment MAN knob Side inle...

Page 10: ...k should be turned to the ON position The I 0 switch should to be set to I The ignition must be connected to the receiver box at the terminal SPARK The transmitter s contains the thermostat sensor sys...

Page 11: ...I2H I3B P PL I3B P SI I2H I3B P SK I2H TR I2H I3B P CATEGORY I2L I2ELL I2H I3P I3 I3B P I2E I2E GAS TYPE G25 G25 G20 25 G31 G30 31 G20 25 G20 25 PREPRESSURE MBAR 25 20 20 30 37 50 28 30 37 50 20 20 BU...

Page 12: ...s and label on receiver OK Transmitter receiver range limited 1 Move antenna cable see instructions 2 Replace receiver Optional wall switch cabling not operating properly Replace wall switch cabling R...

Page 13: ...on see instructions Add ground wire between pilot burner and gas valve Do not coil the IGN cable Shorten IGN cable if possible NO IGN sequence stops no pilot flame Transmitter command is possible IGN...

Page 14: ...smitter command receiver does not react Press RESET button see instructions Add ground wire between pilot burner and gas valve OK Do not coil the IGN cable Shorten IGN cable if possible 7 Main burner...

Page 15: ...r point or jumps c Check whether the electrode is broken The pilot flame will not remain alight after ignition 1 Check whether the pilot flame is large enough to burn around the thermocouple If the fl...

Page 16: ...materials A combustible shelf may be fitted over the appliance up to a depth of 150mm there must be a minimum 280mm clearance above the top of the stove An increase in shelf depth requires an equal in...

Page 17: ...ENDIX 2 PREPARATION AND INSTALLATION PAGE 17 1 2 3 NOTE Some models may feature hexagonal nuts instead of wingnuts In this scenario a suitable socket wrench or spanner can be used to tighten loosen th...

Page 18: ...o account 1 No glowing material should be placed on or near the pilot burner 2 Ensure that no ceramic material can fall on to the glass seals as this can damage the glass 3 The slot opening between th...

Page 19: ...APPENDIX 3 CERAMIC LOG SET PLACEMENT PAGE 19 7 8 9 10 11 12...

Page 20: ...Brought to you by Imperial Point Express Trading Estate Stone Hill Road Farnworth Bolton BL4 9TN Tel 01204 868 550 Fax 01204 868 551 Email sales percydoughty com www visionfires co uk...

Reviews: