The SMS-TEMP-4 has two (3) Inputs and can be connected as per Fig1b or Fig 4 
 
 
 
 
 
 

 

 
 

 

 
 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 

Inputs 

    Ezy Switch SMS-TEMP-4 Installation & Operation 

Temperature Sensor 

     
 
 
 

             

    
 
 Sensor 
Terminal 3-4 
 
 
 
 

Fig 1a 

   Switch 

+10 - 30vdc 

     
 
 
 

             

 Input 1 
Terminal 6 

 

      Or 

 

Input 2 
Terminal 12 

 

      

Or 

 

   Input 3 
Terminal 14 
 

Fig 1b 

     
 
 
 
          
 
 
 
 
 

 

Fig 2 

   Switch / Input2 

Terminal 3 

   Temperature sensor 

Terminal 4 

Terminal 5 

Terminal 6 

   Switch / Input4 

Terminal 11 

   Switch / Input3 

Terminal 12 

Terminal 13 

Terminal 14 

Summary of Contents for EZY SWITCH SMS-TEMP-4

Page 1: ...EZY SWITCH LIMITED SMS TEMP 4 System Monitor Installation Manual...

Page 2: ...ramming the Input reply message 14 Turn an Output ON or OFF 15 Turn an Output ON for a set time 15 Invert Output 15 Make an Output Pulse On and Off 16 Clear Output Pulse Set to non pulsed 16 Make outp...

Page 3: ...Normally Closed Inputs o Programmable for Normally Open or Normally Closed Outputs Inputs and Outputs names are user programmable via text command up to 20 characters Link any Input to any Output Exam...

Page 4: ...Data Retention Outputs Max Input voltage 12 to 30 Volts DC 800mA 40 Milli amps 10 years without power Relay 3 A resistive 125VAC 30vdc SMS TEMP 4 Terminal Electrical Connections Terminal 1 Batt Termi...

Page 5: ...tion Important Note A registered electrician must be used when connecting to the 120 240v main supply voltage Relay 2 Connection Internal Relay Relay Terminals 9 10 Relay 1 Connection Internal Relay R...

Page 6: ...llation Operation Temperature Sensor Sensor Terminal 3 4 Fig 1a Switch 10 30vdc Input 1 Terminal 6 Or Input 2 Terminal 12 Or Input 3 Terminal 14 Fig 1b Fig 2 Switch Input2 Terminal 3 Temperature senso...

Page 7: ...mber without the preceding 0 If the users number is 0414884900 then Command add user 65414884900 USA Canada 001 1 and the Area Code Number If the users number is 414 555 1434 then Command add user 141...

Page 8: ...number XXXXXXXX has been added to the user list Removing a User Command Remove user XXXXXXXX see Country Code page 7 If you try to remove the only user the system responds with Cannot delete the only...

Page 9: ...nit using the Add User command as per above If User lookup is Off the SMS TEM 4 will respond to any number that sends the correct command The system responds with The user lookup list feature has been...

Page 10: ...ts signal strength is run test now The unit will now test the inputs and outputs and waits for the inputs to be triggered When input1 is turned on output1 will turn on when input1 is turned off output...

Page 11: ...name is not currently in the list the system responds with Sorry either that device does not exist or the message format is not understood please check the spelling and try again If the new name chose...

Page 12: ...Make alarm non latching This sets the Input to a NON latched Input and the system responds with The Input INPUT NAME is now a nonlatching input Reset a latched Input used to return Input to non activ...

Page 13: ...The inputs can have a Tick Off feature if this feature is turned on and an input is on the unit will send a reminder text every 5 minutes until the text command Tick INPUT NAME off is sent max number...

Page 14: ...the gate after using The Command for Input1 is Message3 please close the gate after using The Command for Input2 is Message4 please close the gate after using If everything is fine the system respond...

Page 15: ...n also be programmed so when ever the Turn output On command is sent the output will turn on for the programmed time Command Set OUTPUT NAME on time to XX mins or hrs or days If everything is fine the...

Page 16: ...been set as per above the defalt time is 3 seconds and the system responds with OUTPUT NAME is now a pulsing output with a defalt pulse time of 3 seconds If the Output was initially On when the Outpu...

Page 17: ...disabled response text will not be sent Save Output Status This command is used to define if the output state is saved to memory and restored to it state after a power recycle E g if an output was On...

Page 18: ...the alarm has been reset If the value XX X is outside the settings the system responds with Because the value is out of range the voltage alarm has been set to 11 5 volts and the alarm has been reset...

Page 19: ...nds with The battery alarm has been cleared and will begin to be monitored again the linked output has also been turned off If the alarm is not currently set the system responds with The battery alarm...

Page 20: ...is for all users that require the alive text If everything is fine the system responds with The number has been added to the alive text list Get Firmware Version Command Ver The system responds with S...

Page 21: ...nding on the above Set alarm reset temperatures Both low and high alarm temperatures will be automatically reset approx 3 degrees above or below the temperatures depending on if the alarm is low or hi...

Page 22: ...e time in minutes e g Set low temp on delay to 5 mins The system responds with The low alarm delay on time has been set to 5 mins Linking alarms to outputs Both low and high alarm can be linked to an...

Page 23: ...replaced product as its property The equipment has been installed correctly and is used in accordance with the instructions issued with the product In no event will Penguin Electronics Ltd or its agen...

Page 24: ...message Input Name has been turned on If the input turns back off before the programmed time delay expires the input is reset and the time starts back at zero If the input is linked to an output it wi...

Page 25: ...in degrees area Low alarm temp in degrees area Low Alarm The unit will alarm if the current temperature is equal to or less than the programmed low set point temperature e g set point 15 degrees alarm...

Page 26: ...ifferent location 3 SIM card not installed 4 SIM has a pin number remove 5 SIM is locked remove lock LED slow flashes every 3 seconds But no texts are sent or received The unit can find the GSM networ...

Page 27: ...d electronics suppliers This unit is plugged into a conveniently located 120 240v AC outlet on board your vessel and wired as shown in the diagram below fig 1 Name this Input Shore Power using the Com...

Page 28: ...and is now latched When the alarm has been triggered you can reset it by sending the txt Reset Sensor If you want to connect a siren and or flashing light to output1 then Send command text Link Sensor...

Page 29: ...mally closed and go open when activated When the unit detects movement you will receive the following text message The input Door Sensor has been turned on and is now latched When the alarm has been t...

Page 30: ...he Air Con On and pulsed On and Off to be turned Off The SMS TEM 4 has a special command for this type 1 Connect the Air Con to Output1 2 To turn On send Air On Output1 will pulse On and Off trigging...

Page 31: ...31 All technologies design and Intellectual property is owned by Penguin Electronics Ltd New Zealand Version 1 1...