- 23 -
Hardware Installation
Relion 2940 Chassis Manual
5
Installing the Memory
Read the following guidelines before you begin to install the memory:
•
Make sure that the motherboard supports the memory. It is recommended that memory of the
same capacity, brand, speed, and chips be used.
•
Always turn off the computer and unplug the power cord from the power outlet before installing
the memory to prevent hardware damage.
•
Memory modules have a foolproof design. A memory module can be installed in only one
direction. If you are unable to insert the memory, switch the direction.
2-5-1 Four Channel Memory Configuration
The system provides sixteen DDR4 memory sockets and supports Four Channel Technology. After the
memory is installed, the BIOS will automatically detect the specifications and capacity of the memory.
Enabling Four Channel memory mode will be four times of the original memory bandwidth.
The four DDR4 memory sockets are divided into four channels each channel has two memory sockets as
following:
Channel 1: DIMM_P0_A0/DIMM_P0_A1 (For pimary CPU)/
DIMM_P1_E0/DIMM_P1_E1 (For secondary CPU)
Channel 2: DIMM_P0_B0/DIMM_P0_B1 (For pimary CPU)
DIMM_P1_F0/DIMM_P1_F1 (For secondary CPU)
Channel 3: DIMM_P0_C0/DIMM_P0_C1 (For pimary CPU)
DIMM_P1_G0/DIMM_P1_G1 (For secondary CPU)
Channel 4: DIMM_P0_D0/DIMM_P0_D1 (For pimary CPU)
DIMM_P1_H0/DIMM_P1_H1 (For secondary CPU)
DIMM_P0_A0
DIMM_P0_B0
DIMM_P0_A1
DIMM_P0_B1
DIMM_P0_D1
DIMM_P0_C1
DIMM_P1_E1
DIMM_P0_D0
DIMM_P1_F0
DIMM_P0_C0
DIMM_P1_E0
DIMM_P1_F1
DIMM_P1_G1
DIMM_P1_G0
DIMM_P1_H1
DIMM_P1_H0
Type
Ranks Per
DIMM and
Data Width
Speed (MT/s);
Slot Per Channel (SPC) and DIMM Per Channel (DPC)
1 Slot Per Channel
2 Slot Per Channel
1DPC
1DPC
2DPC
RDIMM
SRx4
2133
2133
1866
RDIMM
SRx8
2133
2133
1866
RDIMM
DRx8
2133
2133
1866
RDIMM
DRx4
2133
2133
1866
LRDIMM
QRx4
2133
2133
2133
Summary of Contents for Relion 2940
Page 14: ...Hardware Installation 14 Relion 2940 Chassis Manual 1 3 System Block Diagram...
Page 31: ...31 Hardware Installation Relion 2940 Chassis Manual 3 3 HDD and Nodes Connection...
Page 46: ...BIOS Setup 46 Relion 2940 Chassis Manual 5 2 1 Serial Port Console Redirection...
Page 47: ...47 BIOS Setup Relion 2940 Chassis Manual...
Page 61: ...61 BIOS Setup Relion 2940 Chassis Manual 5 9 SIO Configuration...
Page 66: ...BIOS Setup 66 Relion 2940 Chassis Manual 5 3 1 Processor Configuration...
Page 69: ...69 BIOS Setup Relion 2940 Chassis Manual 5 3 1 1 Pre Socket Configuration...
Page 76: ...BIOS Setup 76 Relion 2940 Chassis Manual 5 3 4 QPI Configuration...
Page 80: ...BIOS Setup 80 Relion 2940 Chassis Manual 5 3 5 1 Memory Topology...
Page 89: ...89 BIOS Setup Relion 2940 Chassis Manual 5 3 7 2 PCH SATA Configuration...