Arctica 4806xp switch Installation Guide       Chapter 2 Installation Notice

 

4

 

with the electronic equipment or lightning protection devices;  

 

Keep away from high power radio transmitters, radar transmitters, and high frequen-
cy strong circuit devices; 

 

Provide electromagnetic shielding if necessary. 

2.1.6.Rack Configuration 

The dimensions of the Arctica 4806xp is designed to be mounted on a standard 19’’ 

rack, please ensure good ventilation for the rack. 

 

Every device in the rack will generate heat during operation, therefore vent and fans 
must be provided for an enclosed rack, and devices should not be stacked closely. 

 

When mounting devices in an open rack, care should be taken to prevent the rack 
frame from obstructing the switch ventilation openings. Be sure to check the posi-
tioning of the switch after installation to avoid the aforementioned. 

 

Caution

 

If a standard 19’’ rack is not available, the Arctica 4806xp can be placed on a clean 

level desktop, leave a clearance of 100mm around the switch for ventilation, and do not 

place anything on top of the switch. 

2.2.Installation Notice 

 

Read through the installation instruction carefully before operating on the system. 

Make sure the installation materials and tools are prepared. And make sure the in-

stallation site is well prepared. 

 

During the installation, users must use the brackets and screws provided in the ac-
cessory kit. Users should use the proper tools to perform the installation. Users 
should always wear antistatic uniform and ESD wrist straps. Users should use 
standard cables and connecters. 

 

After the installation, users should clean the site. Before powering on the switch, us-
ers should ensure the switch is well grounded. Users should maintain the switch 
regularly to extend the lifespan of the switch. 

 

Statement indicating that a readily accessible disconnect device shall be incorpo-
rated in the building installation wiring. 

 

2.3.Security Warnings 

 

When using SFP/SFP+/QSFP+ transceiver, do not stare directly at the fiber bore 
when the switch is in operation. Otherwise the laser may hurt your eyes. 

 

Do not attempt to conduct the operations which can damage the switch or which can 
cause physical injury. 

 

Do not install, move or disclose the switch and its modules when the switch is in op-
eration. 

 

Do not open the switch shell. 

Summary of Contents for Arctica 4806XP Series

Page 1: ...Arctica 4806xp switch Installation Guide Content 1 Arctica 4806xp Series switch Installation Guide Version 1 1 2017 02 07...

Page 2: ...equirements 1 2 1 1 Dust and Particles 1 2 1 2 Temperature and Humidity 2 2 1 3 Power Supply 3 2 1 4 Preventing Electrostatic Discharge Damage 3 2 1 5 Anti interference 3 2 1 6 Rack Configuration 4 2...

Page 3: ...Arctica 4806xp switch Installation Guide Content 3 3 2 7 AC Power Supply Connection 7 3 2 8 Earthing Cable Connection 8 3 2 9 Checking the Switch 9...

Page 4: ...co gent network sustentation for 10Gb connecting to 10Gb scheme in data center and distripark network with the characteristic of high reliability multiple redundancy high con sistency and flexible co...

Page 5: ...ion MAC addresses IP protocols TCP UDP IP precedence time ranges and ToS And various policies can be conducted to forward the traffic By implementing ACL policies users can filter the virus packets su...

Page 6: ...ormance wire speed forward at the same time and provides more help for building the grand IP network Arctica 4806xp supports LDP function and MPLS VPN it can access the public net work and it can be d...

Page 7: ...Caution The USB port on rear panel card only support data transmission does not support USB power supply The rear panel card does not support hot plug The replacement of rear panel card must be opera...

Page 8: ...d is 0 Put out Fan module is power off Table 1 5 The explanation of the port indicator light Indicator light Panel sign State ETHERNET port Link light left Green light Wink The port is transmitting da...

Page 9: ...eivers SFP SX L transceiver SFP LX L transceiver SFP LX 20 L 20 km transceiver SFP LX 40 40 km mid distance transceiver SFP LH 70 L 70 km long distance transceiver SFP LH 120 L 120 km long distance tr...

Page 10: ...47571301 30AWG 3 0m 1 5 Power Supply Module 1 5 1 460W Power Module The following picture is the power supply module of Arctica 4806xp The whole ap pearance sketch map is below Fig 1 4 The sketch map...

Page 11: ...n and a handle for sticking in or pulling out the module on the back of the power supply The power supply module supports the hot plug Caution 460W and 550W power modules can not be mix used Different...

Page 12: ...Specifications of Arctica 4806xp Type Attribute Arctica 4806xp Dimension W H D mm 433 8 44 550 Weight 10 133 kg Fixed Port 48 SFP ports 6 QSFP ports Management Port 1 RJ 45 serial console port Power I...

Page 13: ...dence Keep the switch away from heat sources and strong electromagnetic interference sources The switch must be mounted to a standard 19 rack or placed on a clean level desk top 2 1 1 Dust and Particl...

Page 14: ...ulation spacer to contract making the fastening screw insecure Furthermore in dry environments static electricity is liable to be produced and cause harm to internal circuits Temperature ex tremes can...

Page 15: ...ble power supplying Caution 1 Improper power supply system grounding extreme fluctuation of the input source and transients or spikes can result in larger error rate or even hardware damage 2 Disconne...

Page 16: ...p of the switch 2 2 Installation Notice Read through the installation instruction carefully before operating on the system Make sure the installation materials and tools are prepared And make sure the...

Page 17: ...switch regularly Have the emergence power switch on the site In case of emergence switch off the power immediately Caution Potential risk include Electric leakage Power supply arcing Power line break...

Page 18: ...Installing the Switch Figure 3 1 Arctica 4806xp switch install sketch map on the rack using stock Please mount Arctica 4806xp on the 19 rack as below 1 Attach the 2 brackets on the Arctica 4806xp wit...

Page 19: ...e switch to ensure the proper operation of the switch The figure of back horn iron installation is as below Figure 3 2 The figure of Arctica 4806xp switch installing on the rack by using the front and...

Page 20: ...he following approach 1 The golden finger is entad and aim at the power supply rabbet of the machine to insert to the end downwards You can hear the lock sound of click 2 Force the board on the side o...

Page 21: ...and adown and aim at the fan rabbet of the back machine flatly to the end You can hear the lock sound of click 2 Pinch the sheet metal inward and draw the fan module forth when taking out it Caution...

Page 22: ...ctica 4806xp provides 48 SPF and 6 QSFP ports The procedure for installing the SFP SFP QSFP transceiver is shown below Step 1 Put on a ESD wrist strap or antistatic gloves Step 2 Insert the SFP SFP QS...

Page 23: ...e cap from one end of the fiber cable Keep the fiber end clean and neat Step 2 Attach one end of the fiber cable to the SFP SFP QSFP transceiver and attach the other end to the transceiver of the corr...

Page 24: ...SFP SFP QSFP transceiver of Arctica 4806xp switch 2 Check out the indicator light state of the light port If LINK light is bright it means the link is connection If LINK light puts out it means the l...

Page 25: ...icator in the front panel of the switch The corresponding PWR indicator should light Arctica 4806xp is self adjustable for the input voltage As soon as the input voltage is in the range printed on the...

Page 26: ...from accessories put and screw down the fixed nut on the earth ing pillar of the switch 3 Connect another side of the earthing cable to the earthing side Caution The unit shall be permanently connect...

Reviews: