Arctica 4804iq Series switch Installation Guide         Chapter 2 Installation Notice

 

 

 

Provide electromagnetic shielding if necessary. 

2.1.6.Rack Configuration 

The dimensions of the Arctica 4804iq series are designed to be mounted on a 

standard 19’’ rack, please ensure good ventilation for the rack. 

 

Every device in the rack will generate heat during operation, therefore vent and fans 
must be provided for an enclosed rack, and devices should not be stacked closely. 

 

When mounting devices in an open rack, care should be taken to prevent the rack 
frame from obstructing the switch ventilation openings. Be sure to check the 
positioning of the switch after installation to avoid the aforementioned. 

 

Caution

 

If a standard 19’’ rack is not available, the Arctica 4804iq series can be placed on a 

clean level desktop, leave a clearance of 100mm around the switch for ventilation, and 

do not place anything on top of the switch. 

2.2.Installation Notice 

 

Read through the installation instruction carefully before operating on the system. 

Make sure the installation materials and tools are prepared. And make sure the 

installation site is well prepared. 

  During the installation, users must use the brackets and screws provided in the 

accessory kit. Users should use the proper tools to perform the installation. Users 
should always wear antistatic uniform and ESD wrist straps. Users should use 
standard cables and connecters. 

 

After the installation, users should clean the site. Before powering on the switch, 
users should ensure the switch is well grounded. Users should maintain the switch 
regularly to extend the lifespan of the switch. 

  Statement indicating that a readily accessible disconnect device shall be 

incorporated in the building installation wiring. 

 

2.3.Security Warnings 

 

When using SFP transceiver, do not stare directly at the fiber bore when the switch 
is in operation. Otherwise the laser may hurt your eyes. 

 

Do not attempt to conduct the operations which can damage the switch or which can 
cause physical injury. 

 

Do not install, move or disclose the switch and its modules when the switch is in 
operation. 

 

Do not open the switch shell. 

 

Do not drop metals into the switch. It can cause short-circuit. 

 

Do not touch the power plug and power socket. 

 

Do not place the tinder near the switch. 

Summary of Contents for Arctica 4804iq Series

Page 1: ...Arctica 4804iq Series switch Installation Guide Arctica 4804iq Series switch Installation Guide Version 1 1 2016 04 20...

Page 2: ...Power Supply 3 2 1 4 Preventing Electrostatic Discharge Damage 3 2 1 5 Anti interference 3 2 1 6 Rack Configuration 4 2 2 Installation Notice 4 2 3 Security Warnings 4 3 Device Installation 1 3 1 Ins...

Page 3: ...1000Mb connecting to 10Gb scheme in data center and distripark network Arctica 4804iq figures as follow Figure 1 1 Arctica 4804iq Series Switch Figures 1 2 Description of Hardware 1 2 1 Front Panel 1...

Page 4: ...t as none the default baud rate as 115200bps 1 2 2 Back Panel The back panel of Arctica 4804iq includes 2 alternating current of 220V it provides redundancy backups and 3 fan rabbets Fig 1 3 Back pane...

Page 5: ...The explanation of the port indicator light Indicator light Panel sign State ETHERNET port Link light right Green The port is under the connection state of 10M 100M or 1000M Green winks The port is t...

Page 6: ...egotiation 5 kinds of UTP 100 m SFP SFP SX L transceiver SFP LX L transceiver SFP LX 20 L transceiver SFP LX 40 transceiver SFP LH 70 L transceiver SFP LH 120 L transceiver SFPP 10G SR transceiver SFP...

Page 7: ...pulling out the module on the back of the power supply The power supply module supports the hot plug 1 6 Fan Module Arctica 4804iq series fan module The whole appearance sketch map is below Fig 1 6 T...

Page 8: ...on Fixed Port 48 RJ45 ports 4 SFP ports Management Port 1 RJ 45 serial console port 1 RJ_45 managemen Ethernet port Power Input 90 264VAC 47 63Hz System Consumption 85 2W Operating Temperature 0 C 45...

Page 9: ...eep the switch away from heat sources and strong electromagnetic interference sources The switch must be mounted to a standard 19 rack or placed on a clean level desktop 2 1 1 Dust and Particles Dust...

Page 10: ...s static electricity is liable to be produced and cause harm to internal circuits Temperature extremes can cause reduced reliability and premature aging of insulation materials thus reducing the switc...

Page 11: ...even hardware damage 2 Disconnect power supply cords before servicing 2 1 4 Preventing Electrostatic Discharge Damage Static electric discharges can cause damage to internal circuits even the entire s...

Page 12: ...allation materials and tools are prepared And make sure the installation site is well prepared During the installation users must use the brackets and screws provided in the accessory kit Users should...

Page 13: ...of emergence switch off the power immediately Caution Potential risk include Electric leakage Power supply arcing Power line breakage Imperfect earth Overload circuit and Electrical short circuit If e...

Page 14: ...lease unpack the shipping package and verify carefully the contents inside 3 1 2 Required Tools and Utilities The required tools and utilities are shown below Cross screwdrivers Flat blade screwdriver...

Page 15: ...stock of the rack when installing because the machine is quite heavy 3 Put the bracket mounted switch smoothly into a standard 19 rack Fasten the Arctica 4804iq series to the rack with the screws prov...

Page 16: ...proach 1 Take out the power supply module from the little packing box 2 The golden finger is entad and aim at the power supply rabbet of the machine to insert to the end downwards You can hear the loc...

Page 17: ...R 2 The two power supply module respectively inserted into the chassis power socket the inserted way same as install the one power 3 Force the board on the side of AC cable bore to the direction of fa...

Page 18: ...when pinch press insert and pull it WARNING Hazardous moving parts Keep away from moving fan blades 3 2 4 Connecting Console Arctica 4804iq series provide a serial console port Figure 3 6 Connecting C...

Page 19: ...to the RJ 45 Ethernet port in the switch copper port Step 2 Insert the other end of the Ethernet cable to the RJ 45 Ethernet port of other device Step 3 Check all status indicators for the correspondi...

Page 20: ...responding modules Otherwise it will damage the fiber transceiver Do not stare at the fiber bore when the switch is in operation That may hurt your eyes Figure 3 7 Connect the DAC cable to Arctica 480...

Page 21: ...indicator in the front panel of the switch The corresponding PWR indicator should light series is self adjustable for the input voltage As soon as the input voltage is in the range printed on the swi...

Page 22: ...Arctica 4804iqSeries switch Installation Guide Chapter 3 Device Installation If there are cables at the outside please ensure the cable is well connected with the lightning protection devices...

Reviews: