![PEM SprayWand P-500 Manual Download Page 28](http://html.mh-extra.com/html/pem/spraywand-p-500/spraywand-p-500_manual_1523646028.webp)
26 |
P a g e
Figure 11:
Oil site glass
Change the oil after the initial 50 hours of operation and then after every three
months or 500 hours of operation, whichever occurs first. Change the oil as
follows:
1.
Drain the oil by 1) removing the plug located at the rear of the pump
crankcase or 2) removing the fill plug (Figure 12) and suctioning the oil
out with a suction gun that has a flexible tub.
2.
Fill the crankcase to the red dot on the site glass with
SAE 30-weight oil
,
preferably with no detergent
. Do not overfill.
3.
Replace the check/fill plug.
Figure 12:
Pump oil check/fill plug
Summary of Contents for SprayWand P-500
Page 2: ......
Page 37: ...35 P a g e Figure 23 Pump exploded view ...