![Pelsue PH Series Product Manual Download Page 16](http://html.mh-extra.com/html/pelsue/ph-series/ph-series_product-manual_1523543016.webp)
501144-001 - Product Manual - PH Series Personnel Hoists - Revision 03 Revision Date - 2018-06-13
Page 16
Figure 5b
: PH Series Hoist
Drive Handle Installation
SPRING
PLUNGER
5.5 - Field Operation (continued)
4. Personal Fall Arrest System (PFAS)
In some entry/retrieval applications, OSHA, ANSI and local standards require that the entrant be connected to a Personal
Fall Arrest System. It is the responsibility of the operator to be aware of these requirements and follow them. Always
use a full body harness on the entrant when attached to a PFAS to minimize potential injury to the entrant. Application
limitations for the hoist also apply to a PFAS.
5. Installation/Removal
Pelsue PH Series Personnel Hoists are most commonly used on or with a Pelsue Davit System. Normally, the hoist is
removed from the davit for storage and transporting. When installing or removing the hoist from the davit, follow this
procedure:
a. Installing:
i)
Be sure the quick connect mounting bracket is securely fastened to the structure. Refer to appropriate
Structure Manual for bracket mounting details. See Figure 5a.
ii)
Attach the hoist to the quick connect mounting bracket. Raise the hoist so that the slots on the quick release
bracket of the hoist can slide onto the anchoring rod on the quick connect mounting bracket. See Figure
5c.
iii)
Align the holes on the quick release bracket and the mounting bracket. Secure the hoist using the
attached detent pin. See Figure 5d.
Figure 5c
: PH Series Hoist
Mounting
Figure 5a
: Davit System
Mounting Bracket
QUICk CONNECT
MOUNTING BRACkET
#500101-002
ANCHORING
ROD
BRACkET
SLOTS
Figure 5d
: PH Series Hoist
Detent Pin
PIN
HOLES
DETENT
PIN
Figure 5e
: PH Series Hoist
Fully Mounted
Note:
Prior to mounting the hoist, the drive handle must
be installed to the hoist chassis by pulling on the ring of the
spring plunger and inserting the handle. See Figure 5b