background image

A. 

Insert closed cell foam backer rod 

into the space around the 

WINDOWSOTHEREISAPPROXIMATELYCLEARANCEBETWEENTHE
BACKERRODANDTHEEXTERIORFACEOFTHEWINDOW

 

Note: Backer rod adds shape and depth for the sealant line.

x

B. 

Apply a bead of high quality exterior grade sealant

 to 

the entire perimeter of the window.

 

Note: For wood siding applications, when using 
the flexible fin, ensure the sealant bead covers the 
exterior edge of the fin weather-strip.

INTERIOR FINISHING

)FPRODUCTSCANNOTBElNISHEDIMMEDIATELYCOVERWITHCLEARPLASTICTOPROTECTFROMDIRTDAMAGE
ANDMOISTURE2EMOVEANYCONSTRUCTIONRESIDUEBEFORElNISHING3ANDALLWOODSURFACESLIGHTLY
WITHGRITORlNERSANDPAPER$/./4USESTEELWOOL"%#!2%&5,./44/3#2!4#(
4(%',!332EMOVESANDINGDUST

0ELLAPRODUCTSMUSTBElNISHEDPERTHEBELOWINSTRUCTIONSFAILURETOFOLLOWTHESEINSTRUCTIONS

voids the Limited Warranty.

s/NCASEMENTANDAWNINGSITISOPTIONALTOPAINTSTAINORlNISHTHEVERTICALANDHORIZONTALSASH

   edges.

s/NSINGLEHUNGANDDOUBLEHUNGDONOTPAINTSTAINORlNISHTHEVERTICALSASHEDGESANYlNISH
ONTHEVERTICALSASHEDGESMAYCAUSETHESASHTOSTICKITISOPTIONALTOPAINTSTAINORlNISHTHE
HORIZONTALSASHEDGES
s/NPATIODOORSITISOPTIONALTOPAINTSTAINORlNISHTHEVERTICALANDHORIZONTALPANELEDGES

Note: To maintain proper product performance do not paint, finish or remove the weather-
stripping, mohair dust pads, gaskets or vinyl parts. Air and water leakage will result if these 
parts are removed. After finishing, allow venting windows and doors to dry completely before 
closing them.

0ELLA#ORPORATIONISNOTRESPONSIBLEFORINTERIORPAINTANDSTAINlNISHIMPERFECTIONSFORANY
PRODUCTTHATISNOTFACTORYAPPLIEDBY0ELLA#ORPORATION5SEOFINAPPROPRIATElNISHESSOLVENTS

brickwash, or cleaning chemicals will cause adverse reactions with window and door materials and 
voids the Limited Warranty.

&ORADDITIONALINFORMATIONONlNISHINGSEETHE0ELLA/WNERgS-AUALORGOTO

 www.pella.com.

C. 

Shape, tool and clean excess sealant. 

7HENlNISHED

the sealant should be the shape of an hourglass.

Note: This method creates a more flexible sealant 
line capable of expanding and contracting.

Summary of Contents for 801U0102

Page 1: ...of the terms of the sale Failure to comply with all Pella installation and maintenance instructions may void your Pella product warranty See Limited Warranty for complete details at http warranty pel...

Page 2: ...ny problems with the rough opening before proceeding C Cut the water resistive barrier 1C Additional cutting patterns given below D Fold the water resistive barrier 1D Fold side aps into the opening a...

Page 3: ...them and store them in a protected area 2 SETTING AND FASTENING THE WINDOW C Fold out installation n to 90 N UNITS WITH PRE APPLIED lN CORNERS BE CAREFUL NOT TO REMOVE OR TEAR THE lN CORNERS Note If t...

Page 4: ...ns are folded out to 90 at all points Fasten the window to opening N WINDOWS WITH A lXED EXTRUDED lN DRILL DIAMETER HOLES IN THE lN EVERY A Units that do not have pre applied n corners UT FOUR PIECES...

Page 5: ...e the length of cuts hold the tape along the radius and cut the tape just past where it LEAVES THE TOP lXED EXTRUDED lN OR FOR THE mEXIBLE lN JUST PAST THE mEXIBLE WEATHER STRIP 4HE top tape must over...

Page 6: ...ll the space from the back of the n to the interior face of the opening 5 SEALING THE WINDOW TO THE EXTERIOR WALL CLADDING When applying siding brick veneer or other exterior nish material leave adeq...

Page 7: ...INGLE HUNG AND DOUBLE HUNG DO NOT PAINT STAIN OR lNISH THE VERTICAL SASH EDGES ANY lNISH ON THE VERTICAL SASH EDGES MAY CAUSE THE SASH TO STICK IT IS OPTIONAL TO PAINT STAIN OR lNISH THE HORIZONTAL SA...

Page 8: ...or proper management of moisture within the wall systems The determination of the suitability of all building components including the use of Pella products as well as the design and installation of a...

Reviews: