EN 7
Installation
Before connecting the appliance to the power supply, check that
the wires of your electric installation have sufficient diameter to
supply power to the appliance during normal use. The fuse for the
installation should be 10 amps.
• It is necessary to provide a bipolar cut-off device in the power
supply circuit, with an open contact gap of more than 3 mm.
• The electric connection should be done before the appliance is set
in the cabinet.
• The drawer should be connected by a (standard) power cord with
three 1 mm² wires (1 single phase + 1 N + ground) to the
220-240 V single phase power supply via an electric circuit
corresponding to the CEI 60083 standard or complying with the
installation rules. The protective wire (green/yellow) corresponds to
ground on the appliance and should be connected to the ground of
the installation.
• In the case of a connection via an electric outlet, the outlet should
be accessible even with the appliance installed. The neutral on the
heating drawer (blue wire) should be connected to neutral on the
power supply.
YOUR DRAWER