background image

 

PELEKIS ELECTRONICS                                 

10

   

            ISO9001/2015        

Rev. 1.0   June 2017 

CONDITION 

CONFORMITY 

CERTIFICATION BODIES 

EMISSION 

EN 55022/ΕΝ12015 

Anco Lab 1/12/2003 

VULNERABILITY 

EN 55024/ΕΝ12016  

Anco Lab 1/12/2003 

ESD 

EN  61000-4-2 

EMC HELLAS 0044 15/09/2003 

INJECT CURRENT 

EN  61000-4-6 

EMC HELLAS 0044 15/09/2003 

MAGNETIC FIELD 

EN  61000-4-8 

EMC HELLAS 0044 15/09/2003 

CONTINUOUS NOISE EMISSION 

EN 61000-4-3 

Anco Lab 1/12/2003 

WAVE TRANSMISSION 

EN 61000-4-5 

EMC HELLAS 0044 15/09/2003 

FAST TRANSIENT  

EN 61000-4-4 

EMC HELLAS 0044 15/09/2003 

Test before startup:  

The installer must do the test after installation. 
Tests before starting operation should cover the operation of the alarm system. 
The control and test of the entire system must be in accordance with relevant standards 
of series EN 81.   

Compliance EU: 

Directive 99/5/EC describes <At the discretion of the manufacturer, the device's conformity with the essential 
requirements specified in Article 3 (1) (a) and (b) can be demonstrated using the procedures set out in Directives 
73/ 23/EEC and 89/336/EEC. >.  
The telecommunication devices which do not use radio spectrum - telecommunications and can take part infor-
mation should be subject to the procedures described in any of the Annexes II, IV or V at the discretion of the 
manufacturer. 

 

On standards harmonics:  

For electromagnetic compatibility (Directive 89/336/EEC)  
For safety (Directive73/23/EC) ANCO SA 20/12/2003  
EN 60950 § 2.1.4,2.2.3,6.1,6.2,6.2.1,6.2.1.1,6.3.1,6.3.2  
For efficiency, Certificate No. 2667 17/10/2003 OTE SA  
TBR21, TBR38 KAI ETS300-001.  
For EN 81-28 4,5,6 & 7 EVETAM LF/AC-1155/09. 

 

Summary of Contents for INTD0902

Page 1: ...age 5 Connection diagram Page 6 Device Programming Page 7 8 Basic Programming Page 9 Make an emergency telephone call Page 10 EU Compliance Page 11 12 Certifications Slim Emergency Phone in conjunctio...

Page 2: ...PELEKIS ELECTRONICS 2 ISO9001 2015 Rev 1 0 June 2017 Version history V1 0 06 2017 initial firmware development...

Page 3: ...gency telephone calls The INTD0902 does not require other power source than a telephone line provided from the GSM in order to function properly Caution The installation and setting of the device must...

Page 4: ...2017 Specifications Input Telephone line self powered or 12 to 48VDC Audio controls Microphone to Loudspeaker balance trimmer Microphone sensitivity 46dB 2 0 0 dB 1V Pa at 1K Hz Loudspeaker sensitivi...

Page 5: ...nternet line connected a filter ADSL should be placed in the terminal LINE When there is a line of VOIP Voice Over IP the INTD0902 device should get signal from the modem and not directly from the lin...

Page 6: ...ency telephone numbers in the GSM device the following procedure should be done Step 1 Make sure a GSM device is connected with our Slim emergency phone device INTD0902 and a SIM card is inserted into...

Page 7: ...at has been previ ously inserted The complete command code list can be seen on table2 Command Setup Parameter value description Factory default 080 Adjust speaker volume Key 1 increases tension key 2...

Page 8: ...simcard All calling progress busy not answer and mobile provider will be moderated from the GSM s microcontroller for more flexibility CAUTION Valid only for the devices starting Function deactivated...

Page 9: ...all Terminating a call The device will automatically terminate the calling procedure after the 1st established connection has been terminated Starting a call By holding the BUTTON key for time equal t...

Page 10: ...test of the entire system must be in accordance with relevant standards of series EN 81 Compliance EU Directive 99 5 EC describes At the discretion of the manufacturer the device s conformity with the...

Page 11: ...anufacturer s Address Hr Karvouni 27 AHARNAI Declares that the product Emergency Lift Telephone Product Name Slim Emergency Phone SERIALNumber s FROM TO Product types INTD0902 Conforms with the essent...

Page 12: ...PELEKIS ELECTRONICS 12 ISO9001 2015 Rev 1 0 June 2017...

Reviews: