PELEKIS ELECTRONICS
6
ISO9001/2015
Rev. 1.0 June 2017
Device Programming:
Important - before start programming:
In order to enter programming operation of the device, a keypad must be attached to the
programming connector as seen in Figure1.
Also a connection with a telephone line or GSM carrier is necessary.
Alternatively a 9-12VDC battery connected to terminal “LINE” of device, can be used.
Enter device programming
By pressing PR (PROGRAM) key on the keypad for 1sec and then release, the yellow
LED turns on and the device enters into programming mode.
Program & Store telephone numbers to memory locations
Note:
The programming operation for the emergency call number is done through GSM
device using SMS messages.
In order to program the 4 emergency telephone numbers in the GSM device, the following
procedure should be done.
Step 1:
Make sure a GSM device is connected with our Slim emergency phone device
(INTD0902) and a SIM card is inserted into the socket. In order to ensure that GSM device
is working properly and a stable connection with a telephone provider has been
established, the blue LED should be blink (1s ON - 5s OFF).
Step 2:
We enter a very specific key sequence in an SMS message. The string format is
the following
#0000#1#.
Where “0000” is the default user password to enter the GSM programming mode,
and “1” is the program code to program the telephone number.
Step 3:
Immediately after Step2 we enter the desired 4 telephone numbers, each one
separated with commas, and we finalize the text message by entering an asterisk “*”.
Step 4:
Send the SMS message.
Example:
#0000#1#
2102323345
,
100
,
001234567
,
999
*
NOTE:
If the SIM card has enough credits, an SMS message should respond
with an “OK” text
.