Drive the lift up to the desired maximum height
(1830mm or lower). Slightly loosen the screw that
holds the heel ring in place. Then place the lug on
the ring against the sensor and tighten the screw
again.
The lowering sensor / Down II (2)
The sensor is located on the outside of the ramp
and is set when the lift is delivered. The lowering
task is to stop the lift when the platforms are
20 cm from the ground.
Limit sensor
Note:
Before lowering the lift, reactivate the
photoelectric safety stop by turning the knob in the
control cabinet to the left..
Lowering sensor
The control is
located in the lower
left corner of the
circuit board in the
control cabinet.
Drill the lift to the floor with the 16 M16 expander
bolts that come with the lift.
Drill
Knock down the bolt with a sledgehammer.
Tighten the bolt.
Bundle the remaining cables and hose.
Lay out the cover plates and make markings on the
floor for drilling. Fasten the plates to the floor with
24 M8 expander bolts.