background image

Peha Elektro GmbH & Co. KG

Postfach 1727 • D-58467 Lüdenscheid • Tel.: +49 (0)2351 185-0 • Fax: +49 (0)2351 27666 • e-mail: [email protected] • Internet: www.peha.de 

GB - 1

452-24 FU EP JR o.T. (Rev01_110112)

126471-01

1.  General

1.1  Application

A  roller  shutter,  blinds  or  an  awning  with  end  position 

switch (24V DC motor) can be actuated with the 1

 and 

2

 

output  of  the  receiver.  The  receiver  is  operated  with 

Easyclick transmitters (radio signal). 

Before use, the transmitters must be assigned to the recei-

ver (max. 32 receivers). Every transmitter can control an 

unlimited number of receivers.

Note:

  Read  through  the  operating  instructions  carefully 

before putting the device into service.

1.2  Warranty conditions 

 

These operating instructions are an integral part of both the 

device and our terms of warranty. They must be handed 

over to the user. The technical design of the appliance is 

subject to change without prior notification. 

PEHA

 products 

are manufactured and quality-checked with the latest tech-

nology  according  to  applicable  national  and  international 

regulations. Nevertheless, if a product should exhibit a de-

fect, 

PEHA

 warrants to make remedy as follows (regard-

less of any claims against the dealer to which the end-user 

may be entitled as a result of the sales transaction):

In the event of a justified and properly-established claim, 

PEHA

 shall exercise its prerogative to either repair or re-

place  the  defective  device.  Further  claims  or  liability  for 

consequential damage are explicitly excluded. A justifiable 

deficiency is one in which the device exhibits a structural, 

manufacturing, or material defect that makes it unusable or 

substantially impairs its utility at the time it is turned over to 

the end-user. The warranty does not apply to natural wear, 

unintended usage, incorrect connection, device tampering 

or the effects of external influences. The warranty period is 

for 24 months from the date of purchase by the end-user 

from a dealer and ends not later than 36 months after the 

device’s date of manufacture. German law shall be applica-

ble for the settlement of warranty claims.

1.3  Disposal of the device

The  device  must  be  disposed  of  in  compliance  with  the 

laws and standards of the country in which it is operated!

2.  Safety

This device is only intended to be used for its stated appli-

cation. Unauthorised conversions, modifications or changes 

are not permissible! This device may not be used in con-

junction with other devices whose operation could present a 

hazard to persons, animals or property.

The following must be observed:

•  Prevailing statutes, standards and regulations.

•  State-of-the-art technology at the time of installation.

•  The device’s operating instructions.

•  Operating instructions can only cite general stipulations.

    These are to be viewed in the context of a specific system.

3.  Technical specifications

4.  Installation

This  device  is  intended  for  installation  in  a  flush-mount 

installation  box. They  are  to  be  equipped  with  the  1  -  5 

multipurpose frame from the PEHA switch range.

•   Install flush-mounted installation box in a suitable position.

•  Install connection cables.

•  Insert the device into the flush-mount installation box

  and screw-fasten it securely in place.

•  Switch on power supply after installation.

•  Program the receiver (see Point 5).

5.  Programming

For programming, the receivers must be connected to the 

mains power supply. The programming is retained even in 

a power failure.

5.1  Learn mode (assigning or deleting transmitters)

Notes:

– No transmitter is assigned to the receiver in its 

  delivered state.

– Several transmitters can be assigned (max. 32 receivers)

  or deleted in learn mode.

– A transmitter is alternately assigned (LED on) or deleted

  (LED off) each time the button is pressed!

– The receiver‘s Function 1 is preset after assigning a

  transmitter to the receiver. The function can be changed

  for every transmitter (see point 5.3).

– If no action takes place, learn mode will be terminated 

  after 30 s.

Installation and operating instructions

Easyclick 24V JR-receiver 

Plus

Art.no.: 

452/24 FU-EP JR o.T.

GB

5.2  Deleting all assigned transmitters

5.3  Function programming

Note:

 If no action takes place, function programming will 

be terminated after 30 s.

6.  Operation and functions

6.1   Operating

The receiver is operated with Easyclick transmitters (radio 

signal). Before use, the transmitters must be assigned to 

the receiver (max. 32 receivers). The receiver‘s Function 1 

is preset after assigning a transmitter to the receiver. It can 

be  changed  by  function  programming.  Every  transmitter 

can control an unlimited number of receivers.

6.2   Easyclick wall transmitters

LRN/SET button

 press briefly

Idle state

 (LED off)

CLR/MODE button

 long activation

All transmitters deleted

Learn mode (LED blinks red)

s. Point 5.1

LRN/SET button

 

long activation

Function programming

(LEDs blinks green rapidly)

Function setting

(LED blinks orange 

number of blinks = function)

Press LRN/SET button

(number = function selection)

Transmitter detection

(Activate transmitter once)

CLR/MODE button

press briefly

Parameter setting 

(LED blinks green 

number of blinks = parameter)

Press LRN/SET button

(number = parameter selection)

CLR/MODE 

button

press briefly

Idle state

(LED off)

Transmitter detection 

(e.g. press transmitter button)

Activate transmitter once

LED blinks orange 

 transmitter detected

Function setting

 (e.g. function 3)

LRN/SET button 3 x activated

LED blinks 3 x orange 

 function 3

Parameter setting 

(e.g. parameter 2)

LRN/SET button 2 x activated

LED blinks 2 x green 

 parameter 2

Activate transmitter once

(e.g. press button)

Transmitter assigned

 

(LED 1 on)

Receiver = 

Function 1

Transmitter deleted

(LED off) 

LRN/SET button

press briefly

Idle state

(LED off)

LRN/SET button

press briefly

Learn mode

(LED blinks red)

Transmit frequency

868,3 MHz

Power supply

24V DC

Capacity

1A (24V DC)

Ambient temperature

- 20 to + 40°C

Storage temperature

- 40 to + 85°C

Test specifications

EN 60669-2-1

Identification

CE

Protection type

IP20

Installation information!

Installation and commissioning may only be done by an 

authorised electrician. Mains power 24V DC to electrical 

equipment  must  be  switched  off  during  installation. Ap-

plicable laws and standards of the country in which the 

device is operated must be observed!

•  Do not use outdoors (indoor use only).

•  Installation close to floor level is not recommended.

•  Connect only one motor to the receiver!

•   The direction of rotation of the motor can be changed 

  over without transit time! A motor which permits direct 

  changeover of the direction of rotation is to be used.

•  The 1

 and 2

 outputs of the receiver are interlocked.

•  Only the receiver, to which the transmitter is to be

  assigned, should be in learn mode! If another receiver

  is in learn mode, it is possible that the transmitter may

  be inadvertently assigned to this receiver or deleted!

•  Refer to the operating instructions for the

  Easyclick transmitter!

Hohlwand-Installationsklei
nverteiler

Hörgeschädigtensysmbol

Hubschrauber-Landeplatz
, Warnung vor
Rotorblättern

Hunde tragen während
Rolltreppenbenutzung

Hupen

Hupen geboten
-2.Vorschlag-

Hygienischen Atemschutz
benutzen

Im Brandfall keinen
Aufzug benutzen!

Im Brandfall werden sie
alarmiert! Wenn Sie einen
Brand entdecken, Brand

Impulslichtbogenschweiß
en

Imputz-Installationsdose

Inert-Gas-Einrichrung

Infektiöse Stoffe
[Unterklasse 6.2] [IMO]

Information für die
Feuerwehr

Information,
Informationsstelle

Informieren Sie sich bitte
über die Lage der
Treppen, Notausgänge.

Inline-Skating nicht
gestattet

Installationskanal

Instrumente

Instrumentiertische,
-flächen

Internationaler
Landanschluss

Ionisierende
Strahlungsenergie

Isolierende
Schutzhandschuhe für
Arbeiten unter

Kalibriert

Kaltlicht; Elektromedizin,
Beleuchtung über
Lichtleiter

Karzinogenität
(Gefahrenkategorien 1A,
1B und 2)

Keimzell-Mutagenität
(Gefahrenkategorien 1A,
1B und 2)

Kein Handhaken
verwenden

Kein Trinkwasser

Kein Trinkwasser (ISO)

GND

LRN/SET

CLR/MODE

9

mm

452/24 FU-EP JR o.T.

24VDC

2

1

I

max.1A

N

+

+

-

µ

µ

+

-

+

-

M

Learn mode:

LED = red

Function programming: 

LED = green or orange

+

M

external

24V DC

+ –

1

2

CLR / MODE button 

with LED

Delete all trans-

mitters and para-

meter setting

LRN / SET button

with LED

Learn mode and func-

tion programming.

Button UP

Button

DOWN

Button O

Button I

Reviews: