MAN IN COLD ROOM ALARM KIT COMPONENTS 

THE MAN IN COLD ROOM ALARM KIT consists of: 

- Visual/acoustic alarm control unit complete with buffer battery.
- N° 3 seals, to be inserted between fixing screw and box backing.
- Emergency cold room light switch.
- Use and maintenance manual.

PRODUCT IDENTIFICATION CODE 

6CIAPE03 

kit complete with luminous/acoustic man in 
cold room emergency alarm.  

.                 

TECHNICAL CHARACTERISTICS

 

Mains power supply 

230 V AC 50 Hz 

Max consumption on mains power 

20 mA 

Buffer battery 

12 V DC Ni-MH 1300 mAh 

Complete recharge time: 110 h 

Operating autonomy 

- With 230 V AC NOT ON

(running on charged buffer battery) :

14 h approx. 

- With 230 V AC power ON:

unlimited 

Out-of-room module 

IP 43 protection rating 

Operating temperature: -5 - +45 °C 

Acoustic characteristics 

Type: piezoelectric 

Sound power: 90 dB at 1m 

Visual warning 

Flashing red LED, 12 V DC 

In-room emergency pushbutton  

Lighting: red LED, 12 V DC 

NC contact 

Keypad with IP65 protection rating 

Operating temperature: -25 - +70 °C 

Auxiliary relay 

8A AC1 exchange contact  (Relay deenergized with alarm on) 

1.1

1.2

1.3

- ENG -

USE AND MAINTENANCE MANUAL

 

CHAPTER 1: INTRODUCTION 

CHAP. 1 - Introduction

Summary of Contents for 6CIAPE03

Page 1: ...Alle Angaben sind ohne Gew hr nderungen bleiben CI GmbH CONTROL INSTRUMENTS vorbehalten V 2201 001 manual ECP APE 03...

Page 2: ...HBUTTON UNIT Page 3 1 6 IDENTIFICATION DATA Page 4 1 7 DESCRIPTION OF SYSTEM INSTALLATION Page 5 2 1 INSTALLING THE OUT OF ROOM ALARM CONTROL UNIT Page 6 2 2 INSTALLING THE IN ROOM EMERGENCY PUSHBUTTO...

Page 3: ...n mains power 20 mA Buffer battery 12 V DC Ni MH 1300 mAh Complete recharge time 110 h Operating autonomy With 230 V AC NOT ON running on charged buffer battery 14 h approx With 230 V AC power ON unli...

Page 4: ...IFICATION DATA The unit described in this manual has on its side an ID plate showing all the relevant identification data Name of Manufacturer Code and model of UNIT electrical board Serial number IP...

Page 5: ...mushroom type button with N C contact The pushbutton is permanently lit by LEDs so that it can be located in the dark Acoustic visual alarm control unit to be fitted outside the cold room Features a s...

Page 6: ...ng model see relative table in APPENDICES To effect correct electrical connection and maintain the protection rating use appropriate wire raceway grips to ensure a good seal Route the wiring inside th...

Page 7: ...nous warning devices on the external alarm control unit The auxiliary relay contact closes To deactivate the alarm pull out the emergency illuminated push button again unlock In the event of a 230 V A...

Page 8: ...TTACHMENT SCREWS 4 BUFFER BATTERY SUPPORT FIXING SCREWS 5 BOARD 6 BUFFER BATTERY SUPPORT METAL SHEETING 9 FRONTAL SECTION IN ABS 10 ACOUSTIC VISUAL ALARM 11 BOX CLOSURE SCREWS 12 ACOUSTIC VISUAL ALARM...

Page 9: ...ions have been made it is therefore necessary to connect this fastom to the connector marked 1 on the upper left side of the board as also indicated on the wiring diagram It is advisable to first conn...

Page 10: ...r internal components or any work carried out in a way that fails to comply with the information instructions in this manual shall render the warranty null and void immediately Modifications improper...

Page 11: ...I DELLE SEGUENTI NORME comprese tutte le modifiche THE CONFORMITY WITH THE REQUIREMENTS OF THIS DIRECTIVE IS TESTIFIED BY COMPLETE ADHERENCE TO THE FOLLOWING STANDARDS including all amendments Norme a...

Page 12: ...CI GmbH CONTROL INSTRUMENTS Baumschulenweg 10 70736 Fellbach DE www ci gmbh com info ci gmbh com 49 711 65883 0...

Reviews: