- 55 -
6 Loading
1
5
2
6
3
7
9
4
8
10
Loading and unloading
Loading procedure
1
Stop the cooling operation. (
Refer to page 43.)
2
Load the cargos in the container.
Leave a space between the cargo and inner wall of the container as shown in
the following figure in order to circulate cold air.
50mm or more
30mm or more
30mm or more
Refrigeration Unit
supply air outlet
100mm or more
100mm or more
Lower than supply air outlet
3
Keep the top layer of the cargo as flat as possible.
CAUTION
Waterproof the cargos if they need to be.
• Otherwise, it may deteriorate quality of the cargos due to the
spattering water from defrosting.
4
When loading the cargos which need to be protected from water, cover the
cargos in the vicinity of evaporator outlet with waterproof sheet.
5
After completing loading, start the operation of the refrigeration unit.
(
Refer to page 41.)