5 of 34
ISSUED: 05-29-08 SHEET #: 202-9283-6 12-01-09
Installation to Solid Concrete or Cinder Block
Make sure that wall plate (
A
) is level, use it as a
template to mark six mounting holes. The top mounting
slots should be located 7" (177 mm) above the desired
screen center as shown in figure 1.1 page 4. Drill six
5/16" (8 mm) dia. holes to a minimum depth of 2.5"
(64 mm). Insert anchors (
D
) in holes flush with wall
as shown (right). Place wall plate over anchors and
secure with six wood screws (
C
). Level, then tighten all
fasteners.
C
A
D
solid concrete
cinder block
1
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete
thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid
part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifica-
tions. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to
avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all at-
tached hardware and components.
WARNING
• Tighten screws so that wall plate is firmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
WARNING
• Always attach concrete anchors directly to load-
bearing concrete.
• Never attach concrete anchors to concrete covered
with plaster, drywall, or other finishing material.
If mounting to concrete surfaces covered with a
finishing surface is unavoidable, the finishing surface
must be counterbored as shown below. Be sure
concrete anchors do not pull away from concrete
when tightening screws. If plaster/drywall is thicker
than 5/8", custom fasteners must be supplied by
installer (not evaluated by UL).
WARNING
CUT
A
W
A
Y
VIEW
INCORRECT
CORRECT
wall
plate
wall
plate
plaster/
dry wall
plaster/
dry wall
concrete
concrete
1
3
2
D
Drill holes and insert anchors (
D
).
Place plate (
A
) over anchors (
D
) and secure with screws (
C
).
Tighten all fasteners.
A
K
D
C
concrete
surface