PEERLESS PARAMOUNT PF630  and assembly Installation And Assembly Manual Download Page 5

5 of 24

ISSUED: 11-19-07   SHEET #: 202-9247-5   09-21-09

Installation to Solid Concrete or Cinder Block

Make sure that wall plate (

A

) is level, use it as a 

template to mark two mounting holes. Drill two 5/16" 

(8 mm) dia. holes to a minimum depth of 2.5"  

(64 mm). Insert anchors (

E

) in holes flush with wall 

as shown. Place wall plate over anchors and secure 

with two #14 x 2.5" screws (

D

). Level, then tighten 

all fasteners.

D

CINDER 
BLOCK

SOLID 
CONCRETE

A

E

1

•  When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual 

concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount 

in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM 

C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a 

hammer drill to avoid breaking out the back of the hole when entering a void or cavity.

•  Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
•  Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware 

and components.

WARNING

1

3

2

E

Drill holes and insert anchors (

E

).

Place plate (

A

) over anchors (

E

) and secure with screws (

D

).

Tighten all fasteners.

A

E

D

concrete 

surface

CUT

AW

AY

 VIEW

INCORRECT

CORRECT

wall 

plate

wall 

plate

plaster/

dry wall

plaster/

dry wall

concrete

concrete

•  Tighten screws so that wall plate is firmly attached, 

but do not overtighten. Overtightening can damage 

screws, greatly reducing their holding power.

•  Never tighten in excess of 80 in. • lb (9 N.M.).
•  Always attach concrete expansion anchors directly 

to load-bearing concrete.

•  Never attach concrete expansion anchors to 

concrete covered with plaster, drywall, or other 

finishing material. If mounting to concrete surfaces 

covered with a finishing surface is unavoidable, 

the finishing surface must be counterbored as 

shown below. Be sure concrete anchors do not 

pull away from concrete when tightening screws. 

If plaster/drywall is thicker than 5/8" (16 mm), 

custom fasteners must be supplied by installer (not 

evaluated by UL).

WARNING

Summary of Contents for PARAMOUNT PF630 and assembly

Page 1: ...lation Screen adapter plate simply slides into the wall plate for quick and easy installation Colors Gloss Black Screen adapter plate included compatible with VESA 75 mm and 100 mm mounting patterns I...

Page 2: ...d mechanical aptitude has experience with basic building construction and fully understands these instructions Make sure that the supporting surface will safely support the combined load of the equipm...

Page 3: ...ar slightly different than illustrated E F G H Description Qty PF630 Part A wall plate 1 095 P1496 B hook plate 1 095 P1497 C M5 x 12 mm phillips screw 2 520 1027 D 14 x 2 5 wood screw 2 5S1 015 C03 E...

Page 4: ...ws D as shown Skip to step 2 D A WOOD STUD Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components Tighten woo...

Page 5: ...te must be 2000 psi density minimum Lighter density concrete may not hold concrete anchor Make sure that the wall will safely support four times the combined load of the equipment and all attached har...

Page 6: ...B face toward bottom of screen NOTE If hole pattern is in a pocket attach hook plate B to back of screen using four M4 x 20 mm screws G and four retaining spacers H as indicated Skip to step 5 2 If sc...

Page 7: ...and lift screen off of mount 5 Do not lift more weight than you can handle Use additional man power or mechanical lifting equipment to safely handle placement of the screen WARNING Do not tighten scre...

Page 8: ...talla sencillamente se desliza sobre la placa de pared para proporcionar una instalaci n r pida y f cil Colores Negro lustroso Incluye la placa adaptadora para la pantalla compatible con las configura...

Page 9: ...stalar el producto en una pared con montantes de madera aseg rese de que los tornillos de montaje est n anclados en el centro de los montantes Se recomienda utilizar un localizador de montantes de bor...

Page 10: ...0 1027 D tornillo para madera de 14 x 2 5 2 5S1 015 C03 E anclaje para concreto 2 590 0320 F tornillo phillips M4 x 10 mm 4 504 9012 G tornillo phillips M4 x 20 mm 4 504 9020 H espaciador de retenci n...

Page 11: ...se al paso 2 D A MONTANTE 1 Instalaci n en una pared con montante de madera nico El instalador debe verificar que la superficie de apoyo sea capaz de soportar firmemente la carga combinada del equipo...

Page 12: ...adrar el agujero con un taladro el ctrico normal en velocidad lenta en vez de un taladro percutor para evitar romper la parte trasera del agujero al entrar en un espacio o cavidad El concreto debe ten...

Page 13: ...lla Nota Si la configuraci n de agujeros est en una cavidad fije la placa de montaje B a la parte trasera de la pantalla usando cuatro tornillos de M4 x 20 mm G y cuatro espaciadores de retenci n H co...

Page 14: ...te quite los tornillos C y levante la pantalla para sacarla del soporte 5 No levante m s peso del que puede manejar Cuente con otra persona que lo ayude o utilice un equipo mec nico de izar para levan...

Page 15: ...cran se glisse simplement sur la plaque murale pour une installation rapide et facile Couleurs Noir brillant La plaque d adaptation de l cran incluse est compatible avec les normes de montage VESA 75...

Page 16: ...L Reportez vous la page 15 Lors d une installation sur un mur montants en bois assurez vous que les vis de montage sont ancr es au centre des montants L utilisation d un localisateur de montants bord...

Page 17: ...27 D vis bois no 14 x 2 5 po 2 5S1 015 C03 E chevilles d ancrage pur b ton 2 590 0320 F vis phillips M4 x 10 mm 4 504 9012 G vis phillips M4 x 20 mm 4 504 9020 H entretoise 4 590 5005 Liste des pi ces...

Page 18: ...illustr Passez l tape 2 D A MONTANT 1 Installation sur un mur montant en bois simple L installateur doit s assurer que la surface de support pourra soutenir sans danger la charge combin e de l quipem...

Page 19: ...C 90 Pour percer le trou il est conseill d utiliser une perceuse lectrique standard sur un r glage bas au lieu d un marteau perforateur afin d viter de briser la partie arri re du trou lorsque vous p...

Page 20: ...Remarque Si la configuration des trous est dans un creux attachez la plaque de montage B au dos de l cran l aide de quatre vis M4 x 20 mm G et de quatre entretoises de retenue H comme indiqu Passez l...

Page 21: ...du support retirez les vis C et soulevez le hors du support 5 vitez de trop serrer les vis Un serrage excessif peut endommager le support ATTENTION B A C BRIDES D ACCROCHAGE BRIDES A B Montage et d mo...

Page 22: ...r repairs by the customer or a person who is not authorized for such service or repairs by Peerless Industries Inc b the failure to utilize proper packing when returning the product c incorrect instal...

Page 23: ...nimiento o reparaci n hechos por el cliente o una persona que no est autorizada por Peerless Industries Inc para realizar esos trabajos b no utilizar un embalaje apropiado al devolver el producto c un...

Page 24: ...Industries Inc b la non utilisation de l emballage appropri lors du renvoi du produit c une installation incorrecte ou le non respect des instructions ou des avertissements de Peerless lors de l inst...