PEELLE 224-EN Installation & Interface Manual Download Page 5

1

FREIGHT DOORS

I

CAR GATES

I

CAR ENCLOSURES

T

ECHNICAL 

S

UPPORT

 1-800-787-5020 ext 275

THE PEELLE COMPANY

®

Guide No.

Date: 

224-EN

WIRELESS CONTROLLER 

INSTALLATION & INTERFACE GUIDE

May 13 / 2021

Electrical Hazard Warning Symbol

 – Failure to observe this warning could result in electrical shock 

or electrocution.

Operational Hazard Warning Symbol

 – Failure to observe this warning could result in dangerous or 

unsafe conditions.

Installation Note: 

This  product  should  be  installed  and  serviced  by  a  qualified  elevator  technician 

familiar with its operation and hazards involved.  Proper safety procedures must be followed when 

working with this controller during installation and with control under power.  Proper shielding and 

grounding of this product is necessary to reduce the emissions of radio frequency interference (RFI) 

which may adversely affect sensitive electronic equipment.

Electrical Wiring: 

Wire controller in accordance with the National Electrical Code, Canadian Electrical

Code, European Norms and/or any other local codes that apply.

General Contractor Note:

 A separate fuse disconnect switch is required for the door controllers. See 

job specific wiring diagrams for disconnect and fuse requirements.

1.0  SAFETY WARNING

Enclosure Conduit Connections

TYPE 1, 4 & 4X

(Indoor Use Only)

CAUTION

Non-metallic enclosure does not provide grounding 

between conduit connections. Use grounding bushing 

and jumping wires.

WARNING

Do not mount controller on or above a combustible

surface.

The conduit hubs are to be connected to the conduit 

before being connected to the enclosure.

To maintain the environmental rating of this enclosure, 

install in any openings only listed or recognized conduit 

hubs with the same environmental ratings as required, 

in compliance with the installation instructions of the 

device.

53

T&B Conduit Fittings

Rigid and Intermediate Metal Conduit Fittings

Methods of Bonding and Grounding (continued) —

Typical Installations Using Thomas & Betts Bonding and Grounding Wedge

T&B Series 3651

Bonding & Grounding Wedge

(1) 

T&B Series 142 Locknut

(2)

T&B Series 122 Metallic Bushing

(3)

T&B Series 3651 Bonding &
Grounding Wedge

(4)

T&B Pressure (crimp type) 
Terminal Lug.

Grounding electrode
Conductor enclosure
(Rigid Metal Conduit or
Intermediate Metal Conduit)

Service Enclosure

Service Equipment
Bonding Jumper

Equipment Bonding Jumper

Phase Conductors

Grounding electrode 
conductor

Threaded Rigid Metal Conduit
or intermediate Rigid Metal Conduit

Sheet Metal Box or
Enclosure with unpunched
concentric or eccentric
rings remaining around
knockout opening.

Ground Bus

Acceptable Method for Bonding
Following

(i)

Service Equipment

CEC Rule 10-614

(ii) Bonding for Circuits over 250 volts

CEC Rule 10-614

(iii) Bonding in Hazardous Locations

CEC Rule 18-074

When  installed  with  a  bonding  jumper,
acceptable  method  of  bonding  where
unpunched  rings  remain  around
concentric  or  eccentric  knockouts  in
sheet  metal  boxes  or  enclosures.
[CEC Rule 10-614].

Suggested Specifications

Bonding  and  Grounding  Wedge
(Series 3650)

Bonding  and  Grounding  Wedges
installed  to  effectively  bond  terminating
fitting or metal conduit to a cabinet, box,
enclosure  or  an  auxiliary  gutter  or  to
install 

bonding 

jumper 

around

concentric or eccentric knockouts shall
be  of  the  type  as  manufactured  by
Thomas & Betts—Series 3650.

Bonding  and  Grounding  Wedge

shall be of rugged bronze/tin plated or
steel/electro-zinc plated.

CONFITMRO_1a_fr.pdf   53

9/21/2011   10:15:19 AM

!

Summary of Contents for 224-EN

Page 1: ...LLATION INTERFACE GUIDE May 13 2021 FREIGHT DOORS I CAR GATES I CAR ENCLOSURES TECHNICAL SUPPORT 1 800 787 5020 ext 275 THE PEELLE COMPANY USING AS REPLACEMENT CONTROLLER Confirm software version on e...

Page 2: ......

Page 3: ...OR EMERGENCY UNLOCKING DEVICE EUD 9 2 9 LANDING DOOR ZONE SWITCH ZNS 10 2 10 LANDING DOOR HALL PUSHBUTTONS 11 2 11 LANDING DOOR LIGHT CURTAIN OPTIONAL 12 3 0 CAR DOOR GATE CONTROLLER INSTALLATION 13 3...

Page 4: ...ERFACE GUIDE May 13 2021 6 0 CONTROLLER SETTINGS 26 6 1 DOOR MOTION PROFILES AND PARAMETERS 26 7 0 TROUBLESHOOTING 29 7 1 INDEPENDENT MODE 29 7 2 AUTOMATIC MODE 30 7 3 ELEVATOR INTERFACE OPERATION 31...

Page 5: ...he door controllers See job specific wiring diagrams for disconnect and fuse requirements 1 0 SAFETY WARNING Enclosure Conduit Connections TYPE 1 4 4X Indoor Use Only CAUTION Non metallic enclosure do...

Page 6: ...UIDE May 13 2021 Mount the Landing door Controller to the hoistway wall Use 1 4 inch hardware 2 0 LANDING DOOR CONTROLLER INSTALLATION 2 1 LANDING DOOR CONTROLLER MOUNTING Alternate Location Lowest La...

Page 7: ...TROLLER INSTALLATION INTERFACE GUIDE May 13 2021 2 2 LANDING DOOR WIRING LAYOUT STANDARD OPERATORS Operator Encoder Interlock Operator Landing Door Junction Box or Trough EUD Hall Pushbuttons H O I S...

Page 8: ...ALLATION INTERFACE GUIDE May 13 2021 2 3 LANDING DOOR WIRING LAYOUT EXTRA HIGH TORQUE OPERATORS Operator Encoder Interlock Operator Landing Door Junction Box or Trough EUD Hall Pushbuttons H O I S T W...

Page 9: ...room disconnect 10 amp circuit for each line of doors Use 14AWG 2mm copper wire for power connection ON OFF switch disconnects both lines If neutral is not used main disconnect must break both lines...

Page 10: ...e No Date 224 EN WIRELESS CONTROLLER INSTALLATION INTERFACE GUIDE May 13 2021 GND COMM B A 12V 2 5 LANDING DOOR ENCODER Install and wire encoder same side as the controller Do not extend the encoder w...

Page 11: ...E May 13 2021 2 6 LANDING DOOR OPERATORS STANDARD OPERATORS Wire both door motors in parallel Use 18AWG 1mm wire in conduit for motor connection Do not combine motor wires with control wires in same c...

Page 12: ...e in conduit for motor connection Do not combine motor wires with control wires in same conduit Connect CAN and COMM wires between controllers Notes 1 Low speed winding is not used Cap black wires sep...

Page 13: ...STOP AUX1 INPUT COM V V AUX2 1 2 3 4 5 6 7 Emergency Unlocking Device Add jumper where EUD s are not provided For automatic door operation ALL the EUD switches have to be in the RUN position as shown...

Page 14: ...X2 1 2 3 4 5 6 7 Door Lock Contact DI connect to elevator controller The ZONE indicator will go ON solid when the ZNS contact is made for the door connected to that controller when elevator is at the...

Page 15: ...BUTTON HDC 2 Where provided wire landing station door CLOSE pushbutton as shown When elevator car is within floor ZONE pushbutton inputs will be transmitted to the Car Door controller for connection...

Page 16: ...LLATION INTERFACE GUIDE May 13 2021 2 11 LANDING DOOR LIGHT CURTAIN OPTIONAL Install and wire Landing Door Light Curtain where provided Note V to RE contact must close when beams are blocked RE 8 V Se...

Page 17: ...LLATION INTERFACE GUIDE May 13 2021 3 0 CAR DOOR GATE CONTROLLER INSTALLATION 3 1 CAR DOOR LOCATION AND WIRING LAYOUT Mount the Car Door Controller to the car door rail spreader Mount to same side as...

Page 18: ...e room disconnect 10 amp circuit for each line of doors Use 14AWG 2mm copper wire for power connection ON OFF switch disconnects both lines If neutral is not used main disconnect must break both lines...

Page 19: ...ext 275 THE PEELLE COMPANY Guide No Date 224 EN WIRELESS CONTROLLER INSTALLATION INTERFACE GUIDE May 13 2021 3 3 CAR DOOR ENCODER Install and wire encoder Do not extend the encoder wire GND COMM B A 1...

Page 20: ...ERFACE GUIDE May 13 2021 3 4 CAR DOOR GATE OPERATOR Use 18AWG 1mm wire in conduit for motor connection Do not combine motor wires with control wires in same conduit Note Low speed winding is not used...

Page 21: ...AM MOTOR Use 18AWG lmm wire in conduit for motor connection Do not combine motor wires with control wires in same conduit 4 5 6 Y1 Y2 Y3 Where provided on wide landing doors wire opposite side retirin...

Page 22: ...1 800 787 5020 ext 275 THE PEELLE COMPANY Guide No Date 224 EN WIRELESS CONTROLLER INSTALLATION INTERFACE GUIDE May 13 2021 3 6 CAR DOOR REVERSING EDGE OPTIONAL Wire reversing edge as shown where pro...

Page 23: ...N WIRELESS CONTROLLER INSTALLATION INTERFACE GUIDE May 13 2021 3 7 WARNING BUZZER Install and wire door close warning buzzer as shown See parameter 94 for constant or pulsing tone BUZZER RED BLACK BUZ...

Page 24: ...ter is displayed press the ENTER button to access the setting for that parameter Change the setting by pressing the buttons Once the desired setting is displayed press the ENTER button to save the set...

Page 25: ...ER button to save the setting Parameters can only be modified in IND mode 5 Change parameter 02 to Ld setting The LCD display should now read landing door If you have Extra High Torque Door Operators...

Page 26: ...NTER _ IND AUTO 4 4 SEQUENCE OF OPERATION After power up with the elevator car at a landing upon automatic initiation of either open or close the landing door and car door will operate at learn speed...

Page 27: ...r according to elevator control prints Do not use V or V DO Door Open 1 Constant signal required to open doors DC Door Close 2 Constant signal required to close doors SE Nudging 3 Constant signal requ...

Page 28: ...ing door and car door are open DOOR CLOSED output relay Normally open contact closes and normally closed contact opens when landing door and car door are closed USER 1 output relay Default Normally op...

Page 29: ...are closed 2 All DI hoistway door lock contacts should be connected in series and the contacts be made when all doors are locked When the elevator controller is signaled all doors closed through the D...

Page 30: ...rn and power up speed 40 70 40 40 Car Door Duty increase the car door duty Sd Standard Duty Hd Heavy Duty 23 Open High Speed set the opening high speed 20 99 99 99 24 Open Deceleration Zone set distan...

Page 31: ...ar door USER limit sets USER relay output on car door controller 01 car door USER limit sets USER relay output on car door controller 65 USER 1 options 00 USER1 POSITION 01 USER2 POSITION 02 ZONE 03 B...

Page 32: ...8 Car Door Aux2 Input Option 00 Disabled 01 Independent Car Door Operation with input ON 00 01 N A 00 89 Momentary Door Open Door Close Option 00 Constant DO and DC operation 01 Momentary DO and DC op...

Page 33: ...ng Operational profile not learned Set parameter P10 to Lr to initiate learn sequence Encoder set screw loose Ensure set screw is tight on encoder shaft See Landing Door encoder wiring See Car Door en...

Page 34: ...n at Landing Door controller and corresponding Car Door controller Check all interlock zone micro switches Only one zone micro switch can be on at a time on one channel Duty timer for motor has been e...

Page 35: ...open or final close increase the following parameter s in multiples of 5 until fixed Open direction P27 Close direction P48 Elevator controller is sending outputs to Peelle controller but no Landing C...

Page 36: ...rror codes first two digits 01 Landing door motor run error 02 Car door motor run error 04 Car motor over duty 08 retiring cam motor over duty Landing door error codes first two digits 01 Landing door...

Page 37: ...g applied to motors Landing Zone Zone is ON solid when elevator is at a floor with retiring cam extended and door unlocked Input indicator 3 ZNS is ON when door is ZONED Zone and 3 are OFF when doors...

Page 38: ...ning Door Stop Sign is OFF when power is being applied to motor Landing Zone Zone is ON solid when elevator is at a floor with retiring cam extended and door unlocked Zone is OFF when all doors are lo...

Page 39: ...es on outside perimeter Equipment Class Digital Transmission System Wireless Network 802 15 4 LR WPAN standard Wireless Frequency 2 4GHz Wireless Output 0 094 Watts Wireless Range 100m floor to floor...

Page 40: ...ser s authority to operate the equipment under FCC This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment The user should avoid prolonged exposure within...

Page 41: ...product is used as intended and the following standards applied Product Wireless Freight Door Controller 2 4GHz 802 15 4 Transceiver Module Manufactured by The Peelle Company Ltd Trade mark Peelle Mo...

Page 42: ...38 FREIGHT DOORS I CAR GATES I CAR ENCLOSURES TECHNICAL SUPPORT 1 800 787 5020 ext 275 THE PEELLE COMPANY Guide No Date 224 EN WIRELESS CONTROLLER INSTALLATION INTERFACE GUIDE May 13 2021...

Reviews: