Guide No.

Date: 

224-EN

WIRELESS CONTROLLER 

INSTALLATION & INTERFACE GUIDE

May 13 / 2021

10.0  EC DECLARATION OF CONFORMITY

Manufacturer:

The Peelle Company Ltd.

195 Sandalwood Pkwy W.

Brampton, Ontario  L7A 1J6

CANADA

We, The Peelle Company Limited of Brampton, Ontario, declare that the product designated 

below complies with the relevant fundamental requirements of Article 3 of the Lifts directive 

2014/33/EU insofar as the product is used as intended and the following standards applied:

Product: Wireless Freight Door Controller, 2.4GHz, 802.15.4 Transceiver Module

Manufactured by: The Peelle Company Ltd. Trade mark: Peelle

Model: WFDC 27451 Car Door, WFDC 27452 Landing Door

Environment of use: Residential, commercial and light industry

Standards:

-Lifts EN 81-20:2014 Safety rules for the construction and installation of lifts

EN 12015:2014 Electromagnetic compatibility – Emissions

EN 12016:2013 Electromagnetic compatibility – Immunity

EN 61000-6-1:2007 Electromagnetic compatibility (EMC)

-Telecommunication EN  50371, EN 301 489-1, EN 301 489-17, EN 300 440

Date of issue: MAY 2017

Place of issue: Brampton, Ontario, CA

Frank Leo P.Eng.

Engineering Manager

Summary of Contents for 224-EN

Page 1: ...LLATION INTERFACE GUIDE May 13 2021 FREIGHT DOORS I CAR GATES I CAR ENCLOSURES TECHNICAL SUPPORT 1 800 787 5020 ext 275 THE PEELLE COMPANY USING AS REPLACEMENT CONTROLLER Confirm software version on e...

Page 2: ......

Page 3: ...OR EMERGENCY UNLOCKING DEVICE EUD 9 2 9 LANDING DOOR ZONE SWITCH ZNS 10 2 10 LANDING DOOR HALL PUSHBUTTONS 11 2 11 LANDING DOOR LIGHT CURTAIN OPTIONAL 12 3 0 CAR DOOR GATE CONTROLLER INSTALLATION 13 3...

Page 4: ...ERFACE GUIDE May 13 2021 6 0 CONTROLLER SETTINGS 26 6 1 DOOR MOTION PROFILES AND PARAMETERS 26 7 0 TROUBLESHOOTING 29 7 1 INDEPENDENT MODE 29 7 2 AUTOMATIC MODE 30 7 3 ELEVATOR INTERFACE OPERATION 31...

Page 5: ...he door controllers See job specific wiring diagrams for disconnect and fuse requirements 1 0 SAFETY WARNING Enclosure Conduit Connections TYPE 1 4 4X Indoor Use Only CAUTION Non metallic enclosure do...

Page 6: ...UIDE May 13 2021 Mount the Landing door Controller to the hoistway wall Use 1 4 inch hardware 2 0 LANDING DOOR CONTROLLER INSTALLATION 2 1 LANDING DOOR CONTROLLER MOUNTING Alternate Location Lowest La...

Page 7: ...TROLLER INSTALLATION INTERFACE GUIDE May 13 2021 2 2 LANDING DOOR WIRING LAYOUT STANDARD OPERATORS Operator Encoder Interlock Operator Landing Door Junction Box or Trough EUD Hall Pushbuttons H O I S...

Page 8: ...ALLATION INTERFACE GUIDE May 13 2021 2 3 LANDING DOOR WIRING LAYOUT EXTRA HIGH TORQUE OPERATORS Operator Encoder Interlock Operator Landing Door Junction Box or Trough EUD Hall Pushbuttons H O I S T W...

Page 9: ...room disconnect 10 amp circuit for each line of doors Use 14AWG 2mm copper wire for power connection ON OFF switch disconnects both lines If neutral is not used main disconnect must break both lines...

Page 10: ...e No Date 224 EN WIRELESS CONTROLLER INSTALLATION INTERFACE GUIDE May 13 2021 GND COMM B A 12V 2 5 LANDING DOOR ENCODER Install and wire encoder same side as the controller Do not extend the encoder w...

Page 11: ...E May 13 2021 2 6 LANDING DOOR OPERATORS STANDARD OPERATORS Wire both door motors in parallel Use 18AWG 1mm wire in conduit for motor connection Do not combine motor wires with control wires in same c...

Page 12: ...e in conduit for motor connection Do not combine motor wires with control wires in same conduit Connect CAN and COMM wires between controllers Notes 1 Low speed winding is not used Cap black wires sep...

Page 13: ...STOP AUX1 INPUT COM V V AUX2 1 2 3 4 5 6 7 Emergency Unlocking Device Add jumper where EUD s are not provided For automatic door operation ALL the EUD switches have to be in the RUN position as shown...

Page 14: ...X2 1 2 3 4 5 6 7 Door Lock Contact DI connect to elevator controller The ZONE indicator will go ON solid when the ZNS contact is made for the door connected to that controller when elevator is at the...

Page 15: ...BUTTON HDC 2 Where provided wire landing station door CLOSE pushbutton as shown When elevator car is within floor ZONE pushbutton inputs will be transmitted to the Car Door controller for connection...

Page 16: ...LLATION INTERFACE GUIDE May 13 2021 2 11 LANDING DOOR LIGHT CURTAIN OPTIONAL Install and wire Landing Door Light Curtain where provided Note V to RE contact must close when beams are blocked RE 8 V Se...

Page 17: ...LLATION INTERFACE GUIDE May 13 2021 3 0 CAR DOOR GATE CONTROLLER INSTALLATION 3 1 CAR DOOR LOCATION AND WIRING LAYOUT Mount the Car Door Controller to the car door rail spreader Mount to same side as...

Page 18: ...e room disconnect 10 amp circuit for each line of doors Use 14AWG 2mm copper wire for power connection ON OFF switch disconnects both lines If neutral is not used main disconnect must break both lines...

Page 19: ...ext 275 THE PEELLE COMPANY Guide No Date 224 EN WIRELESS CONTROLLER INSTALLATION INTERFACE GUIDE May 13 2021 3 3 CAR DOOR ENCODER Install and wire encoder Do not extend the encoder wire GND COMM B A 1...

Page 20: ...ERFACE GUIDE May 13 2021 3 4 CAR DOOR GATE OPERATOR Use 18AWG 1mm wire in conduit for motor connection Do not combine motor wires with control wires in same conduit Note Low speed winding is not used...

Page 21: ...AM MOTOR Use 18AWG lmm wire in conduit for motor connection Do not combine motor wires with control wires in same conduit 4 5 6 Y1 Y2 Y3 Where provided on wide landing doors wire opposite side retirin...

Page 22: ...1 800 787 5020 ext 275 THE PEELLE COMPANY Guide No Date 224 EN WIRELESS CONTROLLER INSTALLATION INTERFACE GUIDE May 13 2021 3 6 CAR DOOR REVERSING EDGE OPTIONAL Wire reversing edge as shown where pro...

Page 23: ...N WIRELESS CONTROLLER INSTALLATION INTERFACE GUIDE May 13 2021 3 7 WARNING BUZZER Install and wire door close warning buzzer as shown See parameter 94 for constant or pulsing tone BUZZER RED BLACK BUZ...

Page 24: ...ter is displayed press the ENTER button to access the setting for that parameter Change the setting by pressing the buttons Once the desired setting is displayed press the ENTER button to save the set...

Page 25: ...ER button to save the setting Parameters can only be modified in IND mode 5 Change parameter 02 to Ld setting The LCD display should now read landing door If you have Extra High Torque Door Operators...

Page 26: ...NTER _ IND AUTO 4 4 SEQUENCE OF OPERATION After power up with the elevator car at a landing upon automatic initiation of either open or close the landing door and car door will operate at learn speed...

Page 27: ...r according to elevator control prints Do not use V or V DO Door Open 1 Constant signal required to open doors DC Door Close 2 Constant signal required to close doors SE Nudging 3 Constant signal requ...

Page 28: ...ing door and car door are open DOOR CLOSED output relay Normally open contact closes and normally closed contact opens when landing door and car door are closed USER 1 output relay Default Normally op...

Page 29: ...are closed 2 All DI hoistway door lock contacts should be connected in series and the contacts be made when all doors are locked When the elevator controller is signaled all doors closed through the D...

Page 30: ...rn and power up speed 40 70 40 40 Car Door Duty increase the car door duty Sd Standard Duty Hd Heavy Duty 23 Open High Speed set the opening high speed 20 99 99 99 24 Open Deceleration Zone set distan...

Page 31: ...ar door USER limit sets USER relay output on car door controller 01 car door USER limit sets USER relay output on car door controller 65 USER 1 options 00 USER1 POSITION 01 USER2 POSITION 02 ZONE 03 B...

Page 32: ...8 Car Door Aux2 Input Option 00 Disabled 01 Independent Car Door Operation with input ON 00 01 N A 00 89 Momentary Door Open Door Close Option 00 Constant DO and DC operation 01 Momentary DO and DC op...

Page 33: ...ng Operational profile not learned Set parameter P10 to Lr to initiate learn sequence Encoder set screw loose Ensure set screw is tight on encoder shaft See Landing Door encoder wiring See Car Door en...

Page 34: ...n at Landing Door controller and corresponding Car Door controller Check all interlock zone micro switches Only one zone micro switch can be on at a time on one channel Duty timer for motor has been e...

Page 35: ...open or final close increase the following parameter s in multiples of 5 until fixed Open direction P27 Close direction P48 Elevator controller is sending outputs to Peelle controller but no Landing C...

Page 36: ...rror codes first two digits 01 Landing door motor run error 02 Car door motor run error 04 Car motor over duty 08 retiring cam motor over duty Landing door error codes first two digits 01 Landing door...

Page 37: ...g applied to motors Landing Zone Zone is ON solid when elevator is at a floor with retiring cam extended and door unlocked Input indicator 3 ZNS is ON when door is ZONED Zone and 3 are OFF when doors...

Page 38: ...ning Door Stop Sign is OFF when power is being applied to motor Landing Zone Zone is ON solid when elevator is at a floor with retiring cam extended and door unlocked Zone is OFF when all doors are lo...

Page 39: ...es on outside perimeter Equipment Class Digital Transmission System Wireless Network 802 15 4 LR WPAN standard Wireless Frequency 2 4GHz Wireless Output 0 094 Watts Wireless Range 100m floor to floor...

Page 40: ...ser s authority to operate the equipment under FCC This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment The user should avoid prolonged exposure within...

Page 41: ...product is used as intended and the following standards applied Product Wireless Freight Door Controller 2 4GHz 802 15 4 Transceiver Module Manufactured by The Peelle Company Ltd Trade mark Peelle Mo...

Page 42: ...38 FREIGHT DOORS I CAR GATES I CAR ENCLOSURES TECHNICAL SUPPORT 1 800 787 5020 ext 275 THE PEELLE COMPANY Guide No Date 224 EN WIRELESS CONTROLLER INSTALLATION INTERFACE GUIDE May 13 2021...

Reviews: