Peecker Sound PS266 User Manual Download Page 5

DIGITAL SPEAKER

PS266

PROCESSOR

DIGITAL CROSSOVER

CLIP

LIMIT

-3
-6
-12

-24
-36

CLIP

LIMIT

-3
-6
-12

-24
-36

CLIP

LIMIT

-3
-6
-12

-24
-36

CLIP

LIMIT

-3
-6
-12

-24
-36

CLIP

LIMIT

-3
-6
-12

-24
-36

CLIP

LIMIT

-3
-6
-12

-24
-36

CLIP

LIMIT

-3
-6
-12

-24
-36

CLIP

LIMIT

-3
-6
-12

-24
-36

MUTE

MUTE

MUTE

MUTE

AB

SOUND REINFORCEMENT

CONTROLLED RADIATION

ACOUSTIC RESEARCH

CONTROLLED RADIATION

User’s Manual

PS266

5

POWER

DIGITAL SPEAKER

PS266

PROCESSOR

DIGITAL CROSSOVER

PARAMETER

PREV

NEXT

RECALL

SAVE/ENTER

CLIP

LIMIT

-3

-6
-12

-24
-36

CLIP

LIMIT

-3

-6
-12

-24
-36

CLIP

LIMIT

-3

-6
-12

-24
-36

CLIP

LIMIT

-3

-6
-12

-24
-36

CLIP

LIMIT

-3

-6
-12

-24
-36

CLIP

LIMIT

-3

-6
-12

-24
-36

CLIP

LIMIT

-3

-6
-12

-24
-36

CLIP

LIMIT

-3

-6
-12

-24
-36

MUTE

MUTE

MUTE

MUTE

MUTE

MUTE

A

B

6

A

B

5

4

3

2

1

MIDI OUT

MIDI THRU

MIDI IN

RS232

CONTROLLER INTERFACES

OUTPUTS

INPUTS

               

CAUTION

TO REDUCE THE RISK OF FIRE

   REPLACE ONLY WITH THE

            SAME TYPE

FUSE:T1A/ 250V

90V-240VAC 

 ~ 50/60Hz 30VA

RoHS

 

12

13

10

14

11

2

6

7

9

8

1

3

4

5

          DIGITAL CROSSOVER  

PREV

NEXT

RECALL

POWER

SAVE/ENTER

A

B

CLIP

6

-

12

-

24

-

30

-

3

-

LIMIT

MUTE

MUTE

MUTE

MUTE

MUTE

MUTE

1

2

3

4

5

6

CLIP

6

-

12

-

24

-

30

-

3

-

LIMIT

CLIP

6

-

12

-

24

-

30

-

3

-

LIMIT

CLIP

6

-

12

-

24

-

30

-

3

-

LIMIT

CLIP

6

-

12

-

24

-

30

-

3

-

LIMIT

CLIP

6

-

12

-

24

-

30

-

3

-

LIMIT

CLIP

6

-

12

-

24

-

30

-

3

-

LIMIT

 D IG ITAL  S PE AK ER

  P RO CE SS OR

X T 266

PARAMETER

CAUTION

TO REDUCE THE RISK OF  FIRE 

REPLACE ONLY  WITH THE 

SAME TYPE

FUSE:T1A/ 250V
90V-240V AC

50/60Hz 30VA

CAUTION

TO REDUCE THE RISK OF  FIRE 

REPLACE ONLY  WITH THE 

SAME TYPE

FUSE:T1A/ 250V
90V-240V AC

50/60Hz 30VA

CONTROLLER PS266

    via Monti Urali, 33 - 42100 Reggio Emilia (Italia) • tel. +39 0522 557735 • fax +39 0522 391288 • e-mail: [email protected]

www.peeckersound.com

    via Monti Urali, 33 - 42100 Reggio Emilia (Italia) • tel. +39 0522 557735 • fax +39 0522 391288 • e-mail: [email protected]

www.peeckersound.com

www.peeckersound.com

5.4 Pannello frontale

1) LED bargraph d’ingresso

bargraph

  a  LED 

d’ing

r

esso

 

rispondono

 

ad

  ingr

essi

 

da

  -30 

dB 

a -3 

dB

 e 

segnalano

 il 

clipping

 

del

 

segnale

 in ingr

esso.

 

Indicano 

seguenti

 livelli 

di

 

segnale:

 -30 

dB,

 -24 

dB,

 -6 

dB,

 -3 

dB,

 LIMIT, 

CLIP

.

2) LED bargraphs d’uscita

bargraph

  a  LED 

d’uscita

 

rapp

r

esentano

  il  livello 

di

 

segnale

 

di 

uscita

 relativo alla 

soglia

 

del

 limitator

e. Indicano

 i 

seguenti

 livelli 

di 

segnale: -30 dB, -24 dB, -6 dB, -3 dB, LIMI

T, CLIP

.

3) MUTE

Gli 

indicatori

 

vicino

 ai 

pulsanti

 MUTE 

indicano

 il loro 

stato

 

attuale. 

Pr

emendo

  il 

pulsante

 

si

 

passerà

 

da

 

uno

 

stato

  ON->OFF  e 

viceversa. 

4) Display (2×16 character LCD) 

Lo 

schermo

  LCD 

mostra

 

informazioni

 

sui

 

parametri

 

selezionati. 

La 

schermata

 

di

 

default

 

mostrata

 

dopo

 

l’accensione

 

indica

  il 

nume

ro e il nome 

dell’ultimo

 

p

rogramma 

salvato

 

sulla

 riga 

inferio

r

e. 

Nella  memoria 

dell’unità

 

ci

 

sarà

 

semp

re  almeno 

un

 

p

rogramma 

5) Encoder rotativo

Posizionato

  alla 

destra

 

dello

 

schermo

 

di

 

visualizzazione.

 

E’

 

un 

delle modalità disponibili.

1

 2

 3

 4

 5

 6

 7

 8

 9

6) PREV, NEXT,  

◄ 

Questi

 

pulsanti

 

permettono

 

di

 

accede

re alle varie 

schermate

 e 

di 

seleziona

re il 

paramet

ro 

da

 regolare (PREV / NEXT) 

ed

 il valore 

del 

paramet

ro 

attualmente

 

selezionato

 (

 , 

).

 

Grazie

 a 

questi

 

tasti

 è 

possibile

 

scor

rere 

l’elenco

 

delle

 

opzioni

 nel 

caso

 in 

cui

 il 

paramet

ro 

non sia numerico.

7) RECALL, SAVE/ENTER

Pulsanti

 

da

 

utilizza

re 

per

 

salva

re  i 

p

rogrammi  in 

una

 

nuova 

locazione

 

di

 memoria e 

per

 

richiama

re le 

impostazioni

 

salvate

 in 

memorie  inter

ne.

  Per 

carica

re 

un

 

p

rogramma 

p

r

ecedentemente 

memorizzato,

 

p

remere  il 

pulsante

  RECALL 

sul

 

pannello

 

f

r

ontale. 

Utilizza

re  i 

tasti

  PREV  /  NEXT  a 

destra

 

dello

 

schermo

  LCD 

per 

sceglie

re il 

p

rogramma 

desiderato.

 Premere 

nuovamente

 RECALL 

per

 

richiama

re 

quindi

 il 

p

r

ogramma.

 Per 

salva

re 

un

 

p

rogramma in 

una

 

locazione

 

di

 memoria, 

p

remere il 

tasto

 SAVE, 

seleziona

re la 

locazione

 

di

 memoria 

dove

 

salva

re il 

p

rogramma e 

inseri

re il nome 

del

 

p

r

ogramma.

 Il 

tasto

 SAVE 

può

 

esse

re 

anche

 

utilizzato

 

come 

tasto

  ENTER 

per

  la 

conferma

 

di

 

alcune

 

operazioni.

  Pr

emendo

  il 

tasto S

A

VE, in modalità RECALL, si uscirà dall’operazione.

8) POWER

Interrutto

r

e di accensione

9) Fori per il montaggio

10

 12

 13

 11

 14

5.5 Pannello posteriore

1) Connessione dell’alimentazione

Il  PS266 

deve

 

esse

re 

connesso

 

all’alimentazione

 

usando

  il 

cavo 

fo

r

nito.

  Il 

p

r

ocesso

re 

ha

 

un’alimentazione

 

capace

 

di

 

opera

re 

da 

90V

  a 

250

V, 

50÷60

 

Hz,

 

adattandosi

  alla 

tensione

 

di

  ingr

esso

  in 

modo automatico. 

2) Connettori Audio Input

Le 

connessioni

 

audio

 

d’ing

r

esso

 

sono

 

di

 

tipo

  Cannon  XLR 

elettr

onicamente

  

bilanciate.

 I 

due

 

input

 

costituisco

 

l’ing

r

esso

 

della 

catena DS

P

3) Connettori Audio Output

Le 

connessioni

 

audio

 

d’uscita

 

sono

 

di

 

tipo

  Cannon  XLR 

elettr

onicamente

  

bilanciate.

 I 

sei

 

output

 

costituisco

 le 

uscite

 

di

rette 

ad altri dispositivi.

4) Connettore per le porte di comunicazione 

  

C

P

 

a

i

v

 

o

t

a

ll

o

r

t

n

o

c

 

e

t

n

e

m

a

r

e

t

n

i

 

e

r

e

s

s

e

 

ò

u

p

 

6

6

2

S

P

 

e

r

o

s

s

e

c

o

r

p

 l

I
tramite il 

softwa

re Digital 

Speake

r

.

 La 

connessione

 

sarà

 normalmente 

fatta

 

attraverso

  il 

connetto

re 

della

 

porta

 

seriale

 

(RS232).

 

Questa 

5) Connettori MIDI OUT, MIDI THRU, MIDI IN

del

 Programma e 

per

 

trasmette

re i 

dati

 relativi al 

system

 

exclusive 

dump tra le diverse unità.

6

Figura 3: Pannello f

rontale PS266

Figura 4: Pannello posterio

re PS266

•  Active crossover filters with up to 48 dB/octave slope

•  2 inputs, 6 outputs

•  Max 12 bands for 

parametric

 or 

shelving

 equalization per channel

•  60 memory locations for User Programs

•  Up to 635 ms input and output signal delay (in 21µs steps)

•  Output  limiters  with  adjustable  thresholds  and  attack  and  release 

settings based on cut-off/crossover frequency

•  Front panel controls for muting functions, programming and level settings

•  Security Lock Out modes for protecting setting programs

•  Polarity reversal switch on each output

•  Digital gain adjustment from -15 dB to 15 dB

•  MIDI (

sysex

) dump system to save and transfer data

•  Program compatibility between different units and setting storage capability 

1) LED input bar graphs 

  The LED input bar graphs show the level of input signal, respond to inputs 

from -30 dB to -3 dB and indicate the input signal clipping. The following 

signal levels are displayed: -30 dB, -24 dB, -6 dB, -3 dB, LIMIT, CLIP. 

2) Output LED bar graphs 

  The output LED bar graphs indicate the output signal level in relation to 

the limiter threshold. The following signal levels are displayed: -30 dB, 

-24 dB, -6 dB, -3 dB, LIMIT, CLIP.

3) MUTE 

  The indicators next to the MUTE buttons show their current status. Press 

these buttons to switch the mute function ON>OFF and vice-versa.

4) Display (2x16 character LCD) 

  The LCD display shows information on the selected parameters. The 

bottom line of the default screen appearing after start-up shows the 

number and name of the last program saved. The memory of the unit 

will always contain at least one allocated program if nothing is specified 

in the bottom section. 

5) Rotary encoder

 

  A continuous rotary encoder is located to the right of the display screen. 

It allows the scrolling and selection of the menu parameters and it can 

also modify the parameter values.

6) PREV, NEXT,   ,

 

  These buttons allow access to the various screens and selection of the 

parameter to be adjusted (PREV / NEXT) as well as the value of the selected 

parameter (

 ,

 

). Should the parameter not be numerical, these buttons 

can be used to scroll through the list of options.

7) RECALL, SAVE/ENTER 

  Use these buttons to save the programs in a new memory location and to 

recall settings saved in internal memories. 

  To load a previously memorized program, press the RECALL button on the 

front panel. To select the required program, use the PREV/NEXT buttons to 

the right of the LCD screen, then press RECALL again to call up the program. 

  To save a program in a particular memory location, press SAVE, select 

the memory location where you wish to save the program and enter the 

program name. 

  You can also use the SAVE button as an ENTER key to confirm certain 

operations. Pressing the SAVE key when in RECALL mode will exit the 

operation. 

8) POWER 

  On/Off switch

9) Installation holes

5.5 Rear Panel

10) AC Power socket 

 

The processor has a power supply operating capability ranging from 90 

V to 250 V, at 50/60 Hz, with automatic adjustment to the input voltage. 

11) Audio Input connectors 

 

The audio input connections are made using electronically balanced 

Cannon® XLR connectors. The 

two

 inputs provide the input for the 

DSP chain.

12) Audio Output connectors 

 

The audio output connections are made using electronically balanced 

Cannon® XLR connectors. The 

six

 outputs provide the direct output to 

other devices.  

13) Communication port connectors 

 

The PS266 processor can be entirely controlled via a PC through the 

Digital Speaker

 software. 

 

The connection is normally made via the serial port connector (RS232). 

This port is also used to upgrade the firmware.

14) MIDI OUT, MIDI THRU, MIDI IN connectors

 

The three MIDI connectors are required for transmitting and receiving 

Program changes and for transmitting the system exclusive dump data 

between the different units.

5.4 Front panel

Figure 2. PS266 Front panel

Figure 3. PS266 Rear panel 

5.3 Key features

Summary of Contents for PS266

Page 1: ...evata versatilit grazie alle multiple configurazioni possibili 60 memory address Security lock out Inversione di polarit su ogni uscita Ventilazione forzata e massima dissipazione Predisposto per il m...

Page 2: ...4 5 1 Unpacking 5 2 Installation 5 3 Key features 5 4 Front panel 5 5 Rear panel 6 OPERATING INSTRUCTIONS pag 6 6 1 Connection to the AC mains supply and power absorption 6 2 Connection to an external...

Page 3: ...eller and any product whose serial number has been rubbed off modified or removed Receiving warranty service To receive repair or replacement of the product under warranty the customer must deliver th...

Page 4: ...for the manufacture of a safe reliable and long lasting product Since inappropriate use of the product can jeopardize its correct operating performance please ensure that you use it carefully and corr...

Page 5: ...tuisco le uscite dirette ad altri dispositivi 4 Connettore per le porte di comunicazione C P a i v o t a l l o r t n o c e t n e m a r e t n i e r e s s e u p 6 6 2 S P e r o s s e c o r p l I tramite...

Page 6: ...rating system manual for the modification process Content Each CD contains the files necessary to the software installation System Least Requirements IBM compatible PC Pentium I 133 Mhz 64 MB RAM 500...

Page 7: ...the presets stored in the PC files ay 3 View it allows to choose what to view in the graphic interface 4 Help user s guide Toolbar The toolbar allows a quick access to the following functions from lef...

Page 8: ...pe of filter Low High 6 or Low High12 unlike Bell that has a certain central frequency optimally works from a certain frequency to the device upper limit Freq Equalization frequency Gain height of the...

Page 9: ...ccato Ruotando l encoder sar possibile selezionare l opzione desiderata premere quindi SAVE ENTER una terza volta per completare l operazione Richiamo di un programma Premendo RECALL si entrer in moda...

Page 10: ...a Band6 per le rispettive uscite Modalit 2 channels 3 way Usare l encoder rotativo o i pulsanti in modo tale da visualizzare la videata qui sotto riportata Dopo avere confermato con il tasto ENTER com...

Page 11: ...i separate di tutte le pendenze di crossover Questa modalit utile nell impostazione iniziale di un impianto per regolare la risposta di ogni singolo componente driver 7 6 Unit di ritardo Usare l encod...

Page 12: ...word inserita precedentemente per il blocco premere ENTER per confermare e sbloccare il sistema Modalit Lock set up Ci altri agg Loc la pa IMP luog il m C Una proc ENT la pa nece ed m Prem ritor prot...

Page 13: ...quello di ricezione devono essere impostati sullo stesso canale MIDI PROGRAM Prog It enables the unit to transmit MIDI program changes CONTROLLER PS266 parametri bloccati o togliere complessivamente...

Page 14: ...hiede l autorizzazione del dump in arrivo Se non si desidera sovrascrivere la memoria dell apparecchio ricevente premere il pulsante dell apparecchio ricevente in modo da rispondere No al messaggio Al...

Page 15: ...guadagno amplificatore dB Il ritardo sia per i canali d uscita che per i canali d ingresso pu essere regolato da 0 a 635 ms con passi di 21 s Non possono mai esserci pi di 635ms di ritardo su qualsias...

Page 16: ...lters are available the PREV key will step into an unused Bell EQ with 1 kHz frequency 0 dB cut boost and 0 3 width Provided this EQ is used first further EQs can be assigned to a single channel by ap...

Page 17: ...18 12 6 0 6 12dB Oct 24dB Oct Bessel Frequency Hz Magnitude dB Delay Delay Low Shelf EQ Band Para EQ High Shelf EQ Low Shelf EQ Band Para EQ High Shelf EQ Sum A B Rout nput A put B Band Para EQ High...

Page 18: ...annels 6 Output Gain 15 15 dB Output Polarity norm invert Output HPF Freq 15 Hz 16 kHz Output HPF Shapes But6 But12 But18 But24 But48 Bes12 Bes24 LR12 LR24 LR48 Output LPF Freq 15 Hz 16k Hz Output LPF...

Reviews: