34
| ENGLISH
CONFIGURATION OF THE PARAMETERS
MODIFICATION OF THE PRESSURE OF THE SET
To increase by 0.1 bar
press both the keys at the same time
+
example:
P 3.2
Æ
P 3.3
To decrease by 0.1 bar
press both the keys at the same time
+
example:
P 3.2
Æ
P 3.1
VISUALISATION OF THE FUNCTION PARAMETERS
• To visualise the parameters on the display whilst it is functioning scroll with the keys
• By pressing the key
one returns to the visualisation of the pressure of the system on the display.
DISPLAY
DESCRIPTION
U.M.
P 3.2
SYSTEM PRESSURE
Measured pressure of the system
bar
F 45
WORK FREQUENCY
Immediate frequency of operation of the motor
Hz
A 6.5
ABSORBED CURRENT
Immediate current absorbed by the motor – ATTENTION: RMS value:
the reading of the electric current entering and exiting from the inverter, registered by normal
measuring instruments (eg. amperometric clamp), could be incorrect.
A
Tm 50
TEMPERATURE OF POWER MODULE
Temperature of the electronic power module of the inverter
°C
VISUALISATION OF THE FIRMWARE VERSION (FW)
In order to visualise the FIRMWARE (FW) version of the INTERFACE (FWI) card and the POWER (FWP) card:
• Take the TISSEL-200 OUT OF SERVICE (OFF) by pressing the
key
• Press both the keys at the same time