background image

3.Notice for usage

   

Working environment

Power charging:

    

Please pay attention  the power unit when it's charging.Please disconnect 

the charger and stop charging when the 

 is fully charged.

power pack

    Please charge the power unit every six months after no use for a long time.

AC load:

    Before use the power unit, please ensure the rated power of load power 

is lowers than the rated power. But sometimes the consumed power of 

some appliances is greater than its rated power on power-on,  the overload 

protection will occur and power output will turnoff. For example, the general 

starting current for inductive load equipment is up to 3~8 times of its rated 

power. And its starting power for energy saving lamp is up to dozens of times 

of its rated power; Their starting power is much more than the instant maximum 

power that the power can bear, so the load protection works automatically.

Avoid water and other liquid 

Shady

0

~45

 for charging situation and 

-20

~60

 for discharging situation

At

 

least

 

5cm space around the power 

pack

Safety

Avoid

 

petrol

gas, flammable

 

and

 

other corrosive

 

gas

 

environments

Ventilation

Dry

PORTABLE  POWER  STATION

Summary of Contents for P-II

Page 1: ...P II...

Page 2: ......

Page 3: ...1 2 3 4...

Page 4: ...1 P II P II P II 1 220V 50Hz 110V 60Hz 2 DC12V10A 3 DC20 29 4V20A 4 USB 5V2A 2 5 LED 6 7 8...

Page 5: ...W 1200W 2000W 3000W AC 220V 50Hz AC110V 60Hz DC12V10A DC20 29 4V20A USB 5V2A 642 6Wh 25 2V25 5Ah 1077 44Wh 25 9V41 6Ah 1367 52Wh 25 9V52 8Ah DC29 4V5A DC29 4V10A MAX 5 6h 5 6H 7 8H DC36V10A MAX 0 45 2...

Page 6: ...1 2 3 4 5 2 1 1 2 1 3 24V 1 4 1 5 1 6 1...

Page 7: ...1 12V 12V 12 13 5V 10A 2 LED 3 4 USB DC 12V 5 USB 5V 2A...

Page 8: ...6 20 40 60 80 100 10 7 0 10 20 6 7 8 9...

Page 9: ...10 11 12 8 9 H...

Page 10: ...10 LED 1W 11 24V 20A 20V 29 4V 12...

Page 11: ...13 14 15 DC29 4V 10A 16 13 14 16 15...

Page 12: ...3 3 1 0 45 20 60 5cm 3 2 a 100 b 6 100 100 3 3...

Page 13: ...4 12 3 8 1 2 3 4 5...

Page 14: ......

Page 15: ...User manual for P II PORTABLE POWER STATION...

Page 16: ...Content 1 Product introduction 2 Functions 3 Notice for function 4 Warranty service PORTABLE POWER STATION...

Page 17: ...e fire rescue and is always applied to outdoor emergency situations blackout areas and so on Main functions for P II serial Please read the manual before using the power pack and put it together with...

Page 18: ...ity 642 6Wh 25 2V25 5Ah 1077 44Wh 25 9V41 6Ah 1367 52Wh 25 9V52 8Ah Battery type Lithium ion battery Charging voltage and current DC29 4V5A 36V10A MAX Charging time 5 6H 5 6H 7 8H Solar charging 36V10...

Page 19: ...ly before using the power unit to avoid unnecessary damage Accessories list NO P II accessories Quantity 1 Charging adapter 1 2 Charging cable 1 3 24V DC output cable 1 4 Car charger 1 5 Solar chargin...

Page 20: ...ow the remaining battery volume charge and discharge remaining time 4 Power display button Press the button indicating remaining battery capacity and the USB and DC12V will turn on off at the same tim...

Page 21: ...0 the screen frame flashes for low voltage alarm 7 Remaining power percentage when the battery capacity lower than 0 the battery will reserves a part of the power to protect the battery life and won t...

Page 22: ...discharge due to output efficiency and control board and the cooling fans power the indicating power may a little different than the exact load power 9 Remaining working time According to battery stor...

Page 23: ...is 1W please don t shoot eyes directly 11 24V DC Output Port The DC output port connects to battery output side pass protection board max current is 20A voltage range is 20V 29 4V without overload and...

Page 24: ...n the absence of city power it can be used for emergency power for all appropriate power equipment 15 DC charging port The standard charge voltage is DC29 4V max current is 10A 16 AC output switch Tur...

Page 25: ...er on power on the overload protection will occur and power output will turnoff For example the general starting current for inductive load equipment is up to 3 8 times of its rated power And its star...

Page 26: ...service This product is warranted for 12 months During this time our company will be in charge of it if there is defects on materials and manufacturing And we will offer free repair and main parts acc...

Page 27: ...Certification Item Inspector Date of production Warranty Card Item Product name Purchase date Factory No Client Contact Address Invoice No Dealer Address PORTABLE POWER STATION...

Page 28: ......

Reviews: