background image

2

Intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure
that may be of sufficient magnitude to constitute a risk of electric shock to persons.

Intended to alert the user of the presence of important operating and maintenance (servicing) instructions in the 
literature accompanying the product.

CAUTION: Risk of electrical shock – DO NOT OPEN!
CAUTION: To reduce the risk of electric shock, do not remove cover. No user serviceable parts inside. Refer servicing to 
qualified service personnel.

WARNING: To prevent electrical shock or fire hazard, do not expose this appliance to rain or moisture. Before using this 
appliance, read the operating guide for further warnings.

Este símbolo tiene el propósito de alertar al usuario de la presencia de "(voltaje) peligroso" que no tiene 
aislamiento dentro de la caja del producto que puede tener una magnitud suficiente como para constituir riesgo de 
corrientazo.

Este símbolo tiene el propósito de alertar al usario de la presencia de instruccones importantes sobre la operación 
y mantenimiento en la literatura que viene con el producto.

PRECAUCION: Riesgo de corrientazo – No abra.
PRECAUCION: Para disminuír el riesgo de corrientazo, no abra la cubierta. No hay piezas adentro que el usario pueda 
reparar. Deje todo mantenimiento a los técnicos calificados.

ADVERTENCIA: Para evitar corrientazos o peligro de incendio, no deje expuesto a la lluvia o humedad este aparato 
Antes de usar este aparato, lea más advertencias en la guía de operación.

Ce symbole est utilisé pur indiquer à l'utilisateur la présence à l'intérieur de ce produit de tension non-isolée 
dangereuse pouvant être d'intensité suffisante pour constituer un risque de choc électrique.

Ce symbole est utilisé pour indiquer à l'utilisateur qu'il ou qu'elle trouvera d'importantes instructions sur 
l'utilisation et l'entretien (service) de l'appareil dans la littérature accompagnant le produit.

ATTENTION: Risques de choc électrique – NE PAS OUVRIR!
ATTENTION:  Afin de réduire le risque de choc électrique, ne pas enlever le couvercle. Il ne se trouve à l'intérieur 
aucune pièce pouvant être réparée par l'utilisateur. Confier l'entretien à un personnel qualifié.

AVERTISSEMENT: Afin de prévenir les risques de décharge électrique ou de feu, n'exposez pas cet appareil à la pluie 
ou à l'humidité. Avant d'utiliser cet appareil, lisez les avertissements supplémentaires situés dans le guide.

Dieses Symbol soll den Anwender vor unisolierten gefährlichen Spannungen innerhalb des Gehäuses warnen, die 
von Ausreichender Stärke sind, um einen elektrischen Schlag verursachen zu können.

Dieses Symbol soll den Benutzer auf wichtige Instruktionen in der Bedienungsanleitung aufmerksam machen, die 
Handhabung und Wartung des Produkts betreffen.

VORSICHT: Risiko – Elektrischer Schlag! Nicht öffnen!
VORSICHT: Um das Risiko eines elektrischen Schlages zu vermeiden, nicht die Abdeckung enfernen. Es befinden sich 
keine Teile darin, die vom Anwender repariert werden könnten. Reparaturen nur von qualifiziertem Fachpersonal 
durchführen lassen.

ACHTUNG:  Um einen elektrischen Schlag oder Feuergefahr zu vermeiden, sollte dieses Gerät nicht dem Regen oder 
Feuchtigkeit ausgesetzt werden. Vor Inbetriebnahme unbedingt die Bedienungsanleitung lesen.

Summary of Contents for UMA 35 T II

Page 1: ...1 Cover for UMA 35TII ...

Page 2: ...ymbole est utilisé pur indiquer à l utilisateur la présence à l intérieur de ce produit de tension non isolée dangereuse pouvant être d intensité suffisante pour constituer un risque de choc électrique Ce symbole est utilisé pour indiquer à l utilisateur qu il ou qu elle trouvera d importantes instructions sur l utilisation et l entretien service de l appareil dans la littérature accompagnant le p...

Page 3: ...tch Channel 3 output RCA phono which gives a non mutable output of Channel 3 AUX output for tape recorders etc Signal activity indicator Power indicator SPS Speaker Protection System circuitry with indicator 4 ohm 8 ohm 25 V and 70 V transformer isolated outputs 600 ohm balanced line level output AC convenience outlet Powder coated steel chassis Optional rack mounting kits available Congratulation...

Page 4: ...es 10 dB CONTOUR SWITCH 6 The in position of this switch provides 6 dB boost at 100 Hz and 10 kHz The out position removes boost from the system MASTER 7 Controls the overall volume level of the system POWER ON LED 8 Indicates when AC power is being supplied to the unit SPS COMPRESSION ACTIVE LED 9 Illuminates when SPS circuitry is active SPS eliminates power amplifier clipping ACTIVITY SIGNAL PRE...

Page 5: ... shown in Figure 1 CHANNEL 1 MUTE THRESHOLD 18 Adjusts the level of incoming signal from Channel 1 required to activate the muting of Channels 2 and 3 Clockwise rotation decreases the amount of signal required for muting Full counterclockwise rotation will disable muting NOTE Signal at Channel 1 input with appropriate Mute Threshold setting will mute Channels 2 and 3 CHANNELS 1 TO 3 SCREW TERMINAL...

Page 6: ...er between 4 ohm and XFMR must be installed For 8 ohm speaker systems connect between the COM terminal and the 8 ohm terminal For distributed speaker systems 25 volt and 70 volt outputs are provided One more output is provided on the UMA Series amplifiers This is a balanced transformer isolated line level output This output is provided for direct connec tion to booster power amplifiers etc This ou...

Page 7: ...s The Page input shall be transformer balanced 600 ohms and shall have screw terminals for the input connec tion The master section shall include one Master Volume level control two EQ controls providing 10 dB boost or cut at 100 Hz and 10 kHz and a Contour switch providing 6 dB of boost at 100 Hz and 10 kHz The unit shall have two levels of automatic muting Mute 1 shall give precedence to the Pag...

Page 8: ...tput Loop Out AUX Out 1 V 100 ohms Inputs Channel 1 Low Z 500 µV 1 8 K ohms XLR or screw terminals High Z 50 mV 9 5 K ohms screw terminals Channel 2 Low Z 500 µV 1 8 K ohms screw terminals High Z 50 mV 9 5 K ohms RCA or screw terminals Channel 3 High Z 50 mV 9 5 K ohms RCA Page 100 mV 600 ohm transformer balanced screw terminals Loop In 1 volt 3 6 K ohms Tone Controls Bass 10 dB 100 Hz Treble 10 d...

Page 9: ...9 Flow Diagram ...

Page 10: ... 2 Remote Volume 10 K Lin Taper Potentiometer Shielded Cable Figure 1 GND HIGH Z LOW Z LOW Z BALANCED MIC Low Z Balanced Microphone Input Connections Figure 3 GND HIGH Z LOW Z HIGH Z INPUT High Z Input Connections Figure 2 ...

Page 11: ...HI LO GND 70V 25V 8 Ω COM XFMR 4 Ω Balanced 1V 600Ω GND 1 V Balanced Output Connectors 70V Constant Voltage Distribution System Note Jumper must be in place HI LO GND 70V 25V Jumper Installed 8 Ω COM XFMR 4 Ω Balanced 1V 600Ω GND Figure 5 ...

Page 12: ...GND 70V 25V 8 Ω COM XFMR 4 Ω Balanced 1V 600Ω GND 4 Ω Direct Output to 4Ω Speaker Direct Output to Multiple Speakers in Parallel Total Impedance 4Ω HI LO GND 70V 25V 8 Ω COM XFMR 4 Ω Balanced 1V 600Ω GND 8 Ω 8 Ω Figure 7 ...

Page 13: ...re To Ask About Products In The Following Categories Modular Series Mixer Mixer Amplifiers Rack Kits for MA Series Products Wall Mount Mixer Amplifiers Non powered Mixers Powered Mixers Equalizers Analog Equalizers Programmable Electronic Crossover Delay Processors Power Amplifiers Loudspeaker Systems Acoustical Components Utility Amplifiers Mixer Amplifiers Rack Kits for UMA Series Products Telep...

Page 14: ...old cleaner if necessary Disconnect unit from power supply before cleaning 14 Care should be taken so that objects do not fall and liquids are not spilled into the unit through the ventilation holes or any other openings 15 This unit should be checked by a qualified service technician if a The power supply cord or plug has been damaged b Anything has fallen or been spilled into the unit c The unit...

Page 15: ...ED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR USE UNDER NO CIRCUMSTANCES WILL PEAVEY BE LIABLE FOR ANY LOST PROFITS LOST SAVINGS INCIDENTAL DAMAGES OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THE PRODUCT EVEN IF PEAVEY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE THIS LIMITED WARRANTY IS THE ONLY EXPRESSED WARRANTY ON THIS PRODUCT AND NO OTHER STATE ME...

Page 16: ...specifications subject to change without notice A Division of Peavey Electronics Corporation 711 A Street Meridian MS 39301 U S A 601 483 5376 Fax 486 1154 1995 80302222 Printed in U S A 3 96 ARCHITECTURAL ACOUSTICS TM ...

Reviews: